testdata/extra/wrongName
[version]
# SAP-NOTE=extraNote CATEGORY=extra VERSION=0 DATE=04.06.2019 NAME="Configuration drop in for extra tests"
[mem]
ShmFileSystemSizeMB=25605
VSZ_TMPFS_PERCENT=60
[sysctl]
vm.nr_hugepages = 128
vm.dirty_ratio = 10
vm.dirty_background_ratio = 5
kernel.sem = 250 32000 32 1024
kernel.shmmax = 18446744073709551615
[block]
IO_SCHEDULER = noop, none
NRREQ = 1020
[cpu]
energy_perf_bias = performance
governor = performance
force_latency = 70
[vm]
THP=always
KSM=1
[pagecache]
ENABLE_PAGECACHE_LIMIT = yes
PAGECACHE_LIMIT_IGNORE_DIRTY = 1
OVERRIDE_PAGECACHE_LIMIT_MB = 326046
[limits]
limits="@sapsys soft nofile 32800, @sdba hard nofile 32800"
[grub]
transparent_hugepage=never
[login]
UserTasksMax=infinity
[rpm]
glibc all 2.22-51.6
tuned SLE12 2.8.0-4.3.1
[service]
sysstat=stop
uuidd.socket=start
UnkownService=stop
[reminder]
# Text to ignore for apply but to display.
# Everything the customer should know about this note, especially
# which parameters are NOT handled and the reason.