tools/nexrad_msgs/msg3.spec
Spare N/A N/A N/A N/A N/A See Note (3) 1
Loop Back Test Status Integer*2 N/A 0 to 3 1 0=Pass, 1=Fail, 2=Timeout, 3=Not Tested (1) 2
T1 Output Frames The number of octets received on interface, including frame octets Integer*4 octet 0 to 232-1 1 N/A 3 - 4
T1 Input Frames The number of octets sent on interface, including frame octets Integer*4 octet 0 to 232-1 1 N/A 5 - 6
Router Memory Used Bytes currently in use by applications on managed device Integer*4 byte 0 to 232-1 1 N/A 7 - 8
Router Memory Free Bytes currently free on managed device Integer*4 byte 0 to 232-1 1 N/A 9 - 10
Router Memory Utilization Integer*2 % 0 to 100 1 N/A 11
Spare N/A N/A N/A N/A N/A See Note (3) 12
CSU Loss of Signal Number of times Loss of Signal event detected Integer*4 N/A 0 to 232-1 1 N/A 13 - 14
CSU Loss of Frames Number of times Loss of Frames event detected Integer*4 N/A 0 to 232-1 1 N/A 15 - 16
CSU Yellow Alarms Number of times Resource Availability Indication (RAI) (yellow) alarm received. Integer*4 N/A 0 to 232-1 1 N/A 17 - 18
CSU Blue Alarms Number of times Alarm Indication Signal (AIS) (blue) alarm received. Integer*4 N/A 0 to 232-1 1 N/A 19 - 20
CSU 24hr Errored Seconds Number of errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 21 - 22
CSU 24hr Severely Errored Seconds Number of severely errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 23 - 24
CSU 24hr Severely Errored Framing Seconds Number of severely errored framing seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 25 - 26
CSU 24hr Unavailable Seconds Number of unavailable seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 27 - 28
CSU 24hr Controlled Slip Seconds Number of controlled slip seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 29 - 30
CSU 24hr Path Coding Violations Number of path coding violations in previous 24 hours. Integer*4 N/A 0 to 232-1 1 N/A 31 - 32
CSU 24hr Line Errored Seconds Number of line errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 33 - 34
CSU 24hr Bursty Errored Seconds Number of bursty errored seconds in previous 24 hours. Integer*4 s 0 to 232-1 1 N/A 35 - 36
CSU 24hr Degraded Minutes Number of degraded minutes in previous 24 hours. Integer*4 min 0 to 232-1 1 N/A 37 - 38
LAN Switch Memory Used Bytes currently in use by applications on this device Integer*4 byte 0 to 232-1 1 N/A 39 - 40
LAN Switch Memory Free Bytes currently free on this device Integer*4 byte 0 to 232-1 1 N/A 41 - 42
LAN Switch Memory Utilization Integer*2 % 0 to 100 1 N/A 43
Spare N/A N/A N/A N/A N/A See Note (3) 44
NTP Rejected Packets Number of packets rejected by NTP application layer Integer*4 N/A 0 to 232-1 1 N/A 45 - 46
NTP Estimated Time Error Current estimated time error of the time server SInteger*4 usec -(231) to +(231-1) 1 N/A 47 - 48
GPS Satellites Current number of GPS satellites used in position and time fix calculation SInteger*4 N/A -(231) to +(231-1) 1 N/A 49 - 50
GPS Max Signal Strength Strongest signal strength of all tracking satellites as seen by receiver SInteger*4 dB -(231) to +(231-1) 1 N/A 51 - 52
IPC Status Status of the communications between channels on a redundant system. N/A on a Single channel system. Integer*2 N/A 0 to 2 1 0=OK, 1=Fail, 2=N/A 53
Commanded Channel Control Indicates which channel the RDA has commanded to be the controlling channel. This is not necessarily the channel which is in control. Integer*2 N/A 0 to 2 1 0=N/A, 1=Channel 1, 2=Channel 2 54
DAU Test 0 Tests the performance of the DAU A/D Mutiplexer with a known low voltage input. Integer*2 N/A 0 to 255 1 10 = Normal, 7-11 = Acceptable, All other values= Fault 55
DAU Test 1 Tests the performance of the DAU A/D Mutiplexer with a known medium voltage input. Integer*2 N/A 0 to 255 1 127 = Normal, 118-136 = Acceptable, All other values=Fault 56
DAU Test 2 Tests the performance of the DAU A/D Mutiplexer with a known high voltage input. Integer*2 N/A 0 to 255 1 245 = Normal, 221-252 = Acceptable, All other values=Fault 57
AME Polarization Integer*2 N/A 0 to 2 1 0 = H Only 1 = H + V 2 = V Only 58
AME Internal Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 59-60
AME Receiver Module Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 61-62
AME BITE/CAL Module Temperature Real*4 deg C -40.0 to +125.0 0.1 N/A 63-64
AME Peltier Pulse Width Modulation Integer*2 % 0 to 100 1 N/A 65
AME Peltier Status Integer*2 N/A 0 to 1 1 0 = OFF 1 = ON 66
AME A/D Converter Status Integer*2 N/A 0 to 1 1 0 = OK 1 = FAIL 67
AME State Integer*2 N/A 0 to 3 1 0 = START 1 = RUNNING 2 = FLASH 3 = ERROR 68
AME +3.3V PS Voltage Real*4 V 0.00 to 4.09 0.01 N/A 69-70
AME +5V PS Voltage Real*4 V 0.00 to 6.10 0.01 N/A 71-72
AME +6.5V PS Voltage Real*4 V 0.00 to 7.50 0.01 N/A 73-74
AME +15V PS Voltage Real*4 V 0.00 to 19.00 0.01 N/A 75-76
AME +48V PS Voltage Real*4 V 0.00 to 60.00 0.01 N/A 77-78
AME STALO Power Real*4 V 0.00 to 4.09 0.01 N/A 79-80
Peltier Current Real*4 A 0.00 to 16.00 0.01 N/A 81-82
ADC Calibration Reference Voltage Real*4 V 0.000 to 2.048 0.001 N/A 83-84
AME Mode Integer*2 N/A 0 to 1 1 0 = READY 1 = MAINTENANCE 85
AME Peltier Mode Integer*2 N/A 0 to 1 1 0 = COOL 1 = HEAT 86
AME Peltier Inside Fan Current Real*4 A 0.00 to 4.00 0.01 N/A 87-88
AME Peltier Outside Fan Current Real*4 A 0.00 to 4.00 0.01 N/A 89-90
Horizontal TR Limiter Voltage Real*4 V 0.00 to 5.00 0.01 N/A 91-92
Vertical TR Limiter Voltage Real*4 V 0.00 to 5.00 0.01 N/A 93-94
ADC Calibration Offset Voltage Real*4 mV -50.000 to +50.000 0.01 N/A 95-96
ADC Calibration Gain Correction Real*4 N/A 0.990 to 1.010 0.001 N/A 97-98
Power UPS Battery Status Integer*4 N/A 1 to 3 1 1=Unknown, 2=OK, 3=Low 99 - 100
UPS Time on Battery Integer*4 s 0 to 232-1 1 N/A 101 - 102
UPS Battery Temperature Real*4 deg C N/A 0.01 N/A 103 - 104
UPS Output Voltage Real*4 V 114.00 to 126.00 0.01 N/A 105 - 106
UPS Output Frequency Real*4 Hz 57.00 to 63.00 0.01 N/A 107 - 108
UPS Output Current Real*4 A 0.00 to 12.00 0.01 N/A 109 - 110
Power Administrator Load Real*4 A 0.00 to 12.00 0.01 N/A 111 - 112
Spare N/A N/A N/A N/A N/A See Note (3) 113 - 136
+5 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 137
+15 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 138
+28 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 139
-15 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 140
+45 VDC PS Integer*2 N/A 0 to 1 1 0=OK,1=Fail 141
Filament PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 142
Vacuum Pump PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 143
Focus Coil PS Voltage Integer*2 N/A 0 to 1 1 0=OK,1=Fail 144
Filament PS Integer*2 N/A 0 to 1 1 0=On, 1=Off 145
Klystron Warmup Integer*2 N/A 0 to 1 1 0=Normal, 1=Preheat 146
Transmitter Available Integer*2 N/A 0 to 1 1 0=Yes, 1=No 147
WG Switch Position Integer*2 N/A 0 to 1 1 0=Antenna, 1=Dummy Load 148
WG/PFN Transfer Interlock Integer*2 N/A 0 to 1 1 0=OK, 1=Open 149
Maintenance Mode Integer*2 N/A 0 to 1 1 0= No, 1=Yes 150
Maintenance Required Integer*2 N/A 0 to 1 1 0=No, 1=Required 151
PFN Switch Position Integer*2 N/A 0 to 1 1 0=Short Pulse, 1=Long Pulse 152
Modulator Overload Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 153
Modulator Inv Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 154
Modulator Switch Fail Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 155
Main Power Voltage Integer*2 N/A 0 to 1 1 0=OK, 1=Over 156
Charging System Fail Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 157
Inverse Diode Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 158
Trigger Amplifier Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 159
Circulator Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 160
Spectrum Filter Pressure Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 161
WG ARC/VSWR Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 162
Cabinet Interlock Integer*2 N/A 0 to 1 1 0=OK, 1=Open 163
Cabinet Air Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 164
Cabinet Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 165
Klystron Current Integer*2 N/A 0 to 1 1 N/A 166
Klystron Filament Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 167
Klystron Vacion Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 168
Klystron Air Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 169
Klystron Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 170
Modulator Switch Maintenance Integer*2 N/A 0 to 1 1 0=OK, 1=Required 171
Post Charge Regulator Maintenance Integer*2 N/A 0 to 1 1 0=OK, 1=Maintenance 172
WG Pressure/Humidity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 173
Transmitter Overvoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Over 174
Transmitter Overcurrent Integer*2 N/A 0 to 1 1 0=OK, 1=Over 175
Focus Coil Current Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 176
Focus Coil Airflow Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 177
Oil Temperature Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 178
PRF Limit Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 179
Transmitter Oil Level Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 180
Transmitter Battery Charging Integer*2 N/A 0 to 1 1 0=Yes, 1=No 181
High Voltage (HV) Status Integer*2 N/A 0 to 1 1 0=On, 1=Off 182
Transmitter Recycling Summary Integer*2 N/A 0 to 1 1 0=Normal, 1=Recycling 183
Transmitter Inoperable Integer*2 N/A 0 to 1 1 0=OK, 1=INOP 184
Transmitter Air Filter Integer*2 N/A 0 to 1 1 0=Dirty, 1=OK 185
Zero Test Bit 0 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 186
Zero Test Bit 1 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 187
Zero Test Bit 2 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 188
Zero Test Bit 3 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 189
Zero Test Bit 4 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 190
Zero Test Bit 5 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 191
Zero Test Bit 6 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 192
Zero Test Bit 7 Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 193
One Test Bit 0 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 194
One Test Bit 1 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 195
One Test Bit 2 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 196
One Test Bit 3 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 197
One Test Bit 4 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 198
One Test Bit 5 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 199
One Test Bit 6 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 200
One Test Bit 7 Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 201
XMTR/DAU Interface Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 202
Transmitter Summary Status Integer*2 N/A 0 to 4 1 0=Ready, 1=Alarm, 2=Maintenance, 3=Recycle, 4=Preheat 203
Spare N/A N/A N/A N/A N/A See Note (3) 204
Transmitter RF Power (Sensor) Real*4 mW 0.0000 to 10.0000 .0001 N/A 205 - 206
Horizontal XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 207 - 208
XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 209 - 210
Vertical XMTR Peak Power Real*4 kW 0 to 999.9 0.1 N/A 211 - 212
XMTR RF Avg Power Real*4 W 0 to 9999.9 0.1 N/A 213 - 214
XMTR Power Meter Zero Integer*2 N/A 0 to 255 1 N/A 215
Spare N/A N/A N/A N/A See Note (3) 216
XMTR Recycle Count Integer*4 N/A 0 to 999,999 1 N/A 217 - 218
Receiver Bias Real*4 dB 0 to 999.9999 0.0001 N/A 219 - 220
Transmit Imbalance Real*4 dB 0 to 999.99 0.01 N/A 221 - 222
Spare N/A N/A N/A N/A N/A See Note (3) 223 - 228
AC Unit #1 Compressor Shut off Integer*2 N/A 0 to 1 1 0=OK, 1=Shutoff 229
AC Unit #2 Compressor Shut off Integer*2 N/A 0 to 1 1 0=OK, 1=Shutoff 230
Generator Maintenance Required Integer*2 N/A 0 to 1 1 0=Yes, 1=No 231
Generator Battery Voltage Integer*2 N/A 0 to 1 1 0=Low, 1= OK 232
Generator Engine Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 233
Generator Volt/Frequency Integer*2 N/A 0 to 1 1 0=Not available, 1=Available 234
Power Source Integer*2 N/A 0 to 1 1 0=Utility Power, 1=Generator Power 235
Transitional Power Source (TPS) Integer*2 N/A 0 to 1 1 0=OK, 1=Off 236
Generator Auto/Run/Off Switch Integer*2 N/A 0 to 1 1 0=Manual, 1=Auto 237
Aircraft Hazard Lighting Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 238
DAU UART Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 239
Spare N/A N/A N/A N/A 1 See Note (3) 240 - 249
Equipment Shelter Fire Detection System Integer*2 N/A 0 to 1 1 0 = OK, 1 = Fail 250
Equipment Shelter Fire/Smoke Integer*2 N/A 0 to 1 1 0=OK, 1=Fire 251
Generator Shelter Fire/Smoke Integer*2 N/A 0 to 1 1 0=Fire, 1=OK 252
Utility Voltage/Frequency Integer*2 N/A 0 to 1 1 0=Not available, 1=Available 253
Site Security Alarm Integer*2 N/A 0 to 1 1 0=Alarm, 1=OK 254
Security Equipment Integer*2 N/A 0 to 1 1 0=Fail, 1=OK 255
Security System Integer*2 N/A 0 to 1 1 0=Disabled, 1=OK 256
Receiver Connected to Antenna Integer*2 N/A 0 to 2 1 N/A on a single channel system. 0=Connected, 1=Not Connected, 2=N/A 257
Radome Hatch Integer*2 N/A 0 to 1 1 0=Open, 1=Closed 258
AC Unit #1 Filter Dirty Integer*2 N/A 0 to 1 1 0=Dirty, 1=OK 259
AC Unit #2 Filter Dirty Integer*2 N/A 0 to 1 N/A 0=Dirty, 1=OK 260
Equipment Shelter Temperature Real*4 deg C 0.00 to +50.00 0.01 N/A 261 - 262
Outside Ambient Temperature Real*4 deg C -50.00 to +50.00 0.01 N/A 263 - 264
Transmitter Leaving Air Temp Real*4 deg C -10.00 to +60.00 0.01 N/A 265 - 266
AC Unit #1 Discharge Air Temp Real*4 deg C 0.00 to +50.00 0.01 N/A 267 - 268
Generator Shelter Temperature Real*4 deg C 0.00 to +50.00 0.01 N/A 269 - 270
Radome Air Temperature Real*4 deg C -50.00 to +50.00 0.01 N/A 271 - 272
AC Unit #2 Discharge Air Temp Real*4 deg C 0.00 to +50.00 0.01 N/A 273 - 274
DAU +15v PS Real*4 V 0.00 to 20.00 0.01 N/A 275 - 276
DAU -15v PS Real*4 V -20.00 to 0.00 0.01 N/A 277 - 278
DAU +28v PS Real*4 V 0.00 to 37.40 0.01 N/A 279 - 280
DAU +5v PS Real*4 V 0.00 to 6.64 0.01 N/A 281 - 282
Converted Generator Fuel Level Integer*2 % 0 to 100 1 N/A 283
Spare N/A N/A N/A N/A N/A See Note (3) 284 - 290
+28v PS Real*4 V 0.00 to 40.80 0.01 N/A 291 - 292
Pedestal +15v PS Real*4 V 0.00 to 20.00 0.01 N/A 293 - 294
Encoder +5v PS Real*4 V 0.00 to 18.36 0.01 N/A 295 - 296
Pedestal +5v PS Real*4 V 0.00 to 6.64 0.01 N/A 297 - 298
Pedestal -15v PS Real*4 V -20.00 to 0.00 0.01 N/A 299 - 300
+150V Overvoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Overvoltage 301
+150V Undervoltage Integer*2 N/A 0 to 1 1 0=OK, 1=Overvoltage 302
Elevation Servo Amp Inhibit Integer*2 N/A 0 to 1 1 0=Normal, 1=Inhibit 303
Elevation Servo Amp Short Circuit Integer*2 N/A 0 to 1 1 0=Normal, 1=Short Circuit 304
Elevation Servo Amp Overtemp Integer*2 N/A 0 to 1 1 0=Normal, 1=Overtemp 305
Elevation Motor Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 306
Elevation Stow Pin Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 307
Elevation PCU Parity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 308
Elevation Dead Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 309
Elevation +Normal Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 310
Elevation -Normal Limit Integer*2 N/A 0 to 1 1 0=OK, 1=In Limit 311
Elevation Encoder Light Integer*2 N/A 0 to 1 1 1=Fail, 0=OK 312
Elevation Gearbox Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 313
Elevation Handwheel Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 314
Elevation Amp PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 315
Azimuth Servo Amp Inhibit Integer*2 N/A 0 to 1 1 0=OK, 1=Inhibit 316
Azimuth Servo Amp Short Circuit Integer*2 N/A 0 to 1 1 1=Short Circuit, 0=OK 317
Azimuth Servo Amp Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 318
Azimuth Motor Overtemp Integer*2 N/A 0 to 1 1 0=OK, 1=Overtemp 319
Azimuth Stow Pin Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 320
Azimuth PCU Parity Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 321
Azimuth Encoder Light Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 322
Azimuth Gearbox Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 323
Azimuth Bull Gear Oil Integer*2 N/A 0 to 1 1 0=OK, 1=Oil Level Low 324
Azimuth Handwheel Integer*2 N/A 0 to 1 1 0=Operational, 1=Engaged 325
Azimuth Servo Amp PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 326
Servo Integer*2 N/A 0 to 1 1 0=On, 1=Off 327
Pedestal Interlock Switch Integer*2 N/A 0 to 1 1 0=Operational, 1=Safe 328
Spare N/A N/A N/A N/A N/A See Note (3). 329
Spare N/A N/A N/A N/A N/A See Note (3). 330
Self Test 1 Status Integer*2 N/A 1 to 3 1 1=No, 2=OK, 3=Fail See Note(1) 331
Self Test 2 Status Integer*2 N/A 1 to 3 1 1=No, 2=OK, 3=Fail See Note(1) 332
Self Test 2 Data Integer*2 N/A N/A 1 Hex See Note (2) 333
Spare N/A N/A N/A N/A N/A See Note (3) 334 - 340
COHO/Clock Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 341
Rf Generator Frequency Select Oscillator Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 342
Rf Generator RF/STALO Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 343
Rf Generator Phase Shifted COHO Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 344
+9v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 345
+5v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 346
O/18v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 347
-9v Receiver PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 348
+5v Single Channel RDAIU PS Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 349
Spare N/A N/A N/A N/A N/A See Note (3) 350
Horizontal Short Pulse Noise Real*4 dBm -100.00 to -50.00 0.01 N/A 351 - 352
Horizontal Long Pulse Noise Real*4 dBm -100.00 to -50.00 0.01 N/A 353 - 354
Horizontal Noise Temperature Real*4 K 0 to 9999.99 0.01 N/A 355 - 356
Vertical Noise Short Pulse N/A N/A N/A N/A N/A See Note (3) 357 - 358
Vertical Noise Long Pulse Real*4 dBm -100.00 to -50.00 0.01 N/A 359-360
Vertical Noise Temperature Real*4 K 0 to 9999.99 0.01 N/A 361-362
Horizontal Linearity Real*4 N/A 0.5000 to 1.5000 0.0001 N/A 363 - 364
Horizontal Dynamic Range Real*4 dB 0.000 to 120.000 0.001 N/A 365 - 366
Horizontal Delta dBZ0 Real*4 dB -198.00 to +198.00 0.01 N/A 367 - 368
Vertical Delta dBZ0 Real*4 dB -198.00 to +198.00 0.01 N/A 369 - 370
KD Peak Measured Real*4 dBm -99.90 to +99.90 0.01 N/A 371 - 372
Spare N/A N/A N/A N/A N/A See Note (3) 373 - 374
Short Pulse, Horizontal dBZ0 Real*4 dBZ -99.900 to +99.900 0.0001 N/A 375 - 376
Long Pulse, Horizontal dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 377 - 378
Velocity (Processed) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 379
Width (Processed) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 380
Velocity (RF Gen) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 381
Width (RF Gen) Integer*2 N/A 0 to 1 1 0=Good, 1=Fail 382
Horizontal I0 Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 383 - 384
Vertical I0 Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 385 - 386
Vertical Dynamic Range Real*4 dB 0.000 to 120.000 0.001 N/A 387 - 388
Short Pulse, Vertical dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 389 - 390
Long Pulse, Vertical dBZ0 Real*4 dBZ -99.9000 to +99.9000 0.0001 N/A 391 - 392
Spare N/A N/A N/A N/A N/A See Note (3) 393 - 394
Spare N/A N/A N/A N/A N/A See Note (3) 395 - 396
Horizontal Power Sense Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 397 - 398
Vertical Power Sense Real*4 dBm -999.9000 to +999.9000 0.0001 N/A 399 - 400
ZDR Bias Real*4 dB -999.9000 to +999.9000 0.0001 N/A 401 - 402
Spare N/A N/A N/A N/A N/A See Note (3) 403 - 408
Clutter Suppression Delta Real*4 dB -99.90 to +99.90 0.01 N/A 409-410
Clutter Suppression Unfiltered Power Real*4 dBZ -99.90 to +99.90 0.01 N/A 411 - 412
Clutter Suppression Filtered Power Real*4 dBZ -99.90 to +99.90 0.01 N/A 413 - 414
Transmit Burst Power Real*4 dBm -99.90 to +99.90 0.01 N/A 415 - 416
Transmit Burst Phase Real*4 deg -99.00 to +99.90 0.01 N/A 417 - 418
Spare N/A N/A N/A N/A N/A See Note (3) 419 - 422
Spare N/A N/A N/A N/A N/A See Note (3) 423 - 424
Vertical Linearity Real*4 N/A 0.5000 to 1.5000 0.0001 N/A 425 - 426
Spare N/A N/A N/A N/A N/A See Note (3) 427 - 430
State File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 431
State File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 432
Bypass Map File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 433
Bypass Map File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 434
Spare N/A N/A N/A N/A N/A See Note (3) 435
Spare N/A N/A N/A N/A N/A See Note (3) 436
Current Adaptation File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 437
Current Adaptation File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 438
Censor Zone File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 439
Censor Zone File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 440
Remote VCP File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 441
Remote VCP File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 442
Baseline Adaptation File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 443
Spare N/A N/A N/A N/A N/A See Note (3) 444
Clutter Filter Map File Read Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 445
Clutter Filter Map File Write Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 446
General Disk I/O Error Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 447
Spare N/A N/A N/A N/A N/A See Note (3) 448 - 460
DAU Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 461
HCI Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 462
Pedestal Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 463
Signal Processor Comm Status Integer*2 N/A 0 to 1 1 0=OK, 1=Fail 464
AME Communication Status Integer*2 N/A 0 to 1 1 0 = OK 1 = FAIL 465
RMS Link Status Integer*2 N/A 0 to 1 1 0 = Connected, 1 = Not Connected 466
RPG Link Status Integer*2 N/A 0 to 1 1 0 = Connected, 1 = Not Connected 467
Spare N/A N/A N/A N/A N/A See Note (3) 468
Performance Check Time Integer*4 N/A N/A 1 469 - 470
Spare N/A N/A N/A N/A N/A See Note (3) 471 - 480