librenms/librenms

View on GitHub
mibs/ericsson/PT-RADIOLINK-MIB

Summary

Maintainability
Test Coverage
PT-RADIOLINK-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        MODULE-IDENTITY,OBJECT-TYPE,Counter32, Integer32, IpAddress  FROM SNMPv2-SMI
        TEXTUAL-CONVENTION FROM SNMPv2-TC
        MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
        InetAddressIPv6 FROM INET-ADDRESS-MIB
        ifEntry FROM IF-MIB
        pt FROM PT-MIB;


    ptRadioLink MODULE-IDENTITY
        LAST-UPDATED "201712011600Z"
        ORGANIZATION "Ericsson"
        CONTACT-INFO
            "Anders Ekvall
             Postal: Ericsson AB,
             E-Mail: anders.ekvall@ericsson.com"

        DESCRIPTION
            "This is the MIB for Radio Link specifics in PT"

        REVISION      "201712011600Z"
        DESCRIPTION
        "Added plcAdminStatus and plcOperStatus."

        REVISION      "201704051000Z"
        DESCRIPTION
        "Added channelSpacing enums."

        REVISION      "201701181000Z"
        DESCRIPTION
        "Added mlhcAdminStatus, mlhcOperStatus and mlhcMplsConfig."

        REVISION      "201612061400Z"
        DESCRIPTION
            "Added more MOs in ctTable and rltTable. Added G.826 tables."

        REVISION      "201605221030Z"
        DESCRIPTION
            "The initial version of this MIB module
                            with OID for MINI-LINK."


        ::= { pt 7 }

     ptRadioLinkConformance OBJECT IDENTIFIER ::= { ptRadioLink 2 } 
     ctPerformance OBJECT IDENTIFIER ::= { ptRadioLink 4 }

---
--- Textual conventions
---
     AcmTC ::= TEXTUAL-CONVENTION
     STATUS     current
     DESCRIPTION
            "An integer which indicates the ACM."
     SYNTAX INTEGER
     {
         acmHalfBpsk(1),
         acmHalfBpskLight(2),
         acmHalfBpskStrong(3),
         acmBpsk(4),
       acmBpskLight(5),
       acmBpskStrong(6),
       acm4Qam(7),
       acm4QamLight(8),
       acm4QamStrong(9),
       acm16Qam(10),
       acm16QamLight(11),
       acm16QamStrong(12),
       acm32Qam(13),
       acm32QamLight(14),
       acm32QamStrong(15),
       acm64Qam(16),
       acm64QamLight(17),
       acm64QamStrong(18),
       acm128Qam(19),
       acm128QamLight(20),
       acm128QamStrong(21),
       acm256Qam(22),
       acm256QamLight(23),
       acm256QamStrong(24),
       acm512Qam(25),
       acm512QamLight(26),
       acm512QamStrong(27),
       acm1024Qam(28),
       acm1024QamLight(29),
       acm1024QamStrong(30),
       acm2048Qam(31),
       acm2048QamLight(32),
       acm2048QamStrong(33),
       acm4096Qam(34),
       acm4096QamLight(35),
       acm4096QamStrong(36)
     }


     EnableStatusTC ::= TEXTUAL-CONVENTION
     STATUS     current
     DESCRIPTION
            "An integer which indicates the enabled status."     
     SYNTAX INTEGER
     {
       enabled(1),
       disabled(2),
       unknown(3)
     }

     XpicMimoTC ::= TEXTUAL-CONVENTION
     STATUS     current
     DESCRIPTION
            "An integer which indicates the XPIC or MIMO status."     
     SYNTAX INTEGER
     {
       notAvailable(1),
       locked(2),
       unlocked(3),
       unknown(4)
     }

---
---The definition of ctTable
---   
  ctTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF CtEntry
    MAX-ACCESS  not-accessible
    STATUS current
    DESCRIPTION
            "A table of CT Table entries."
        ::= { ptRadioLink 1 }

  ctEntry OBJECT-TYPE
        SYNTAX      CtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                  "An entry of CT application."
        AUGMENTS   { ifEntry }
        ::= { ctTable 1 }

  CtEntry ::=
        SEQUENCE {
              actualInputPower                OCTET STRING,
              actualOutputPower               OCTET STRING,
              actualRxAcm                     OCTET STRING,
              actualTxAcm                     OCTET STRING,
              ctDistinguishedName             OCTET STRING,
              description                     OCTET STRING,
              carrierId                       INTEGER,
              ctStatus                        INTEGER,
              frameId                         Integer32,
              txFrequency                     Integer32,
              minTxFrequency                  Integer32,
              maxTxFrequency                  Integer32,
              rxFrequency                     Integer32,
              minRxFrequency                  Integer32,
              maxRxFrequency                  Integer32,
              frequencyStepSize               Integer32,
              duplexDistance                  Integer32,
              duplexType                      INTEGER,
              duplexConfig                    EnableStatusTC,
              autoFreqSelection               INTEGER,
              autoFreqSelectedChannel         Integer32,
              autoFreqSelectionStatus         INTEGER,
              channelSpacing                  INTEGER,
              polarization                    INTEGER,
              txOperStatus                    INTEGER,
              txAdminStatus                   INTEGER,
              selectedOutputPowerType         INTEGER,
              availableOutputPowerType        INTEGER,
              selectedMinOutputPower          Integer32,
              selectedMaxOutputPower          Integer32,
              availableMinOutputPower         Integer32,
              availableMaxOutputPower         Integer32,
              referenceSec                    INTEGER,
              targetInputPowerFarEnd          Integer32,
              berAlarmThreshold               INTEGER,
              inputPowerAlarmThreshold        Integer32,
              plannedAlignmentInputPower      Integer32,
              atpcFallback                    EnableStatusTC,
              atpcFallbackTimer               Integer32,
              atpcFallbackOutputPower         Integer32,
              xpicStatus                      XpicMimoTC,
              mimoStatus                      XpicMimoTC,
              actualSnir                      OCTET STRING,
              actualXpi                       OCTET STRING,
              actualSi                        OCTET STRING,
              actualTxCapacity                Integer32,
              licensedCapacity                Integer32,
              availableMinCapacity            Integer32,
              availableMaxCapacity            Integer32,
              selectedMinCapacity             Integer32,
              selectedMaxCapacity             Integer32,
              wantedLicensedCapacity          Integer32,
              availableMinAcm                 AcmTC,
              availableMaxAcm                 AcmTC,
              selectedMinAcm                  AcmTC,
              selectedMaxAcm                  AcmTC,
              actualRxAcmTC                   AcmTC,
              actualTxAcmTC                   AcmTC,
              alignmentMode                   EnableStatusTC,
              rfLoop                          EnableStatusTC
              }

  actualInputPower OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Actual input power of the CT in dBm"
        ::= { ctEntry 1 }

  actualOutputPower OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Actual output power of the CT in dBm"
        ::= { ctEntry 2 }

  actualRxAcm       OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Actual rx modulation and coding"
        ::= { ctEntry 3 } 

  actualTxAcm       OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Actual tx modulation and coding"
        ::= { ctEntry 4 } 

  ctDistinguishedName OBJECT-TYPE
            SYNTAX      OCTET STRING
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
            "Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)"
            ::= { ctEntry 5 }

  description OBJECT-TYPE
            SYNTAX      OCTET STRING
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                "User description of the carrior termination."
            ::= { ctEntry 6 }

  carrierId       OBJECT-TYPE
            SYNTAX INTEGER
            {
                a(1),
                b(2),
                c(3),
                d(4),
                unknown(5)
            }     
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                "Id of the carrier. (A, B, C, D)
                Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. 
                Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC.
                Sometimes also referred to as preamble"
            ::= { ctEntry 7 }

  ctStatus  OBJECT-TYPE
        SYNTAX INTEGER
        {
            down(1),
          up(2),
          na(3),
          unknown(4),
          degraded(5)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The status of the carrier termination, hop"
        ::= { ctEntry 8}

  frameId  OBJECT-TYPE
        SYNTAX Integer32 (0..10000)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "A unique identifier for the radio frame to be used. 
            Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
        ::= { ctEntry 9}

  txFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Selected frequency on the transmitter (kHz). 
                Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
            ::= { ctEntry 10}

  minTxFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Minimum Tx frequency possible to use, given by the selected frame-id"
            ::= { ctEntry 11}

  maxTxFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Maximum Tx frequency possible to use, given by the selected frame-id"
  ::= { ctEntry 12}

  rxFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Selected frequency on the receiver (kHz). 
                Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
  ::= { ctEntry 13}

  minRxFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Minimum Rx frequency possible to use, given by the selected frame-id"
  ::= { ctEntry 14}

  maxRxFrequency  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Maximum Rx frequency possible to use, given by the selected frame-id"
            ::= { ctEntry 15}

  frequencyStepSize  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Frequency step size in kHz"
            ::= { ctEntry 16}

  duplexDistance  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Distance between Tx and Rx frequencies (kHz)"
            ::= { ctEntry 17}

  duplexType  OBJECT-TYPE
            SYNTAX INTEGER
            {
                variable(1),
                fixed(2),
                unknown(3)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The duplex type is given by the equipment (Fixed,Variable)"
            ::= { ctEntry 18}


  duplexConfig  OBJECT-TYPE
        SYNTAX EnableStatusTC
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Enabling or disabling configuration of Rx freq using duplex distance"
        ::= { ctEntry 19}

  autoFreqSelection  OBJECT-TYPE
      SYNTAX INTEGER
      {
        disabled(1),
        master(2),
        slave(3),
        unknown(4)
      }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Automatic frequency selection mode"
        ::= { ctEntry 20}

    autoFreqSelectedChannel  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Automatic frequency selected channel"
      ::= { ctEntry 21}

    autoFreqSelectionStatus  OBJECT-TYPE
      SYNTAX INTEGER
      {
          idle(1),
        searchingForSlave(2),
        requestingInfoFromSlave(3),
        waitingForMaster(4),
        waitingForChannelInfoRequest(5),
        inProgress(6),
        initializing(7),
        finished(8),
        failed(9),
        unknown(10)
      }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Automatic frequency status"
      ::= { ctEntry 22}

  channelSpacing  OBJECT-TYPE
      SYNTAX INTEGER
      {
        cs7MHz(1),
        cs10MHz(2),
        cs14MHz(3),
        cs20MHz(4),
        cs28MHz(5),
        cs30MHz(6),
        cs40MHz(7),
        cs50MHz(8),
        cs56MHz(9),
        cs250MHz(10),
        cs60MHz(11),
        cs500MHz(12),
        cs750MHz(13),
        cs100MHz(14),
        cs150MHz(15),
        cs200MHz(16),
        cs125MHz(17),
        cs80MHz(18),
        cs112MHz(19),
        cs1000MHz(20),
        cs1250MHz(21),
        cs1500MHz(22),
        cs62p5MHz(23),
        cs2000MHz(24),
        unknown(25)       
      }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "Channel spacing"
      ::= { ctEntry 23}

  polarization  OBJECT-TYPE
      SYNTAX INTEGER
      {
        notSpecified(1),
        horizontal(2),
        vertical(3),
        unknown(4)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Antenna polarization"
      ::= { ctEntry 24}

  txOperStatus  OBJECT-TYPE
      SYNTAX INTEGER
      {
        unknown(1),
        off(2),
        on(3),
        standby(4)
      }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Operative status of the transmitter"
      ::= { ctEntry 25}

  txAdminStatus  OBJECT-TYPE
      SYNTAX INTEGER
      {
        off(1),
        on(2),
        unknown(3)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Administrative status of the transmitter"
      ::= { ctEntry 26}

  selectedOutputPowerType  OBJECT-TYPE
      SYNTAX INTEGER
      {
        standard(1),
        high(2),
        unknown(3)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Selected output power type"
      ::= { ctEntry 27}

  availableOutputPowerType  OBJECT-TYPE
      SYNTAX INTEGER
      {
        standard(1),
        high(2),
        unknown(3)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Available output power type"
      ::= { ctEntry 28}

  selectedMinOutputPower  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Selected min output power.
       Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
      ::= { ctEntry 29}

  selectedMaxOutputPower  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Selected max output power.
       Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
      ::= { ctEntry 30}


  availableMinOutputPower  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "The minimum output power supported (dBm).
        The system shows a value if the equipment is available and a frame id has been selected."
      ::= { ctEntry 31}

  availableMaxOutputPower  OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The maximum output power supported (dBm).
            The system shows a value if the equipment is available and a frame id has been selected."
  ::= { ctEntry 32}

  referenceSec  OBJECT-TYPE
        SYNTAX INTEGER
        {
            noAvailable(1),
            sec2(2),
        sec4L(4),
        sec4H(5),
        sec5B(7),
        sec6B(9),
        sec5LB(10),
        sec5HB(11),
        sec6LB(12),
        sec6HB(13),
        sec7B(14),
        unknown(15)
        }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). 
            When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM.
            This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements.
            Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
        ::= { ctEntry 33}

 targetInputPowerFarEnd  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "The wanted input power at far end (dBm), when running ATPC"
      ::= { ctEntry 34}

 berAlarmThreshold  OBJECT-TYPE
      SYNTAX INTEGER
      {
        tenExpMinus6(1),
        tenExpMinus3(2)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Threshold for the BER alarm"
      ::= { ctEntry 35}

 inputPowerAlarmThreshold  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
        "Threshold for the input power alarm"
      ::= { ctEntry 36}

    plannedAlignmentInputPower  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power.
                    Used when doing alignment"
            ::= { ctEntry 37}

    atpcFallback  OBJECT-TYPE
     SYNTAX EnableStatusTC
     MAX-ACCESS read-write
     STATUS current
     DESCRIPTION
        "Enable or disable the output power fall back function"
     ::= { ctEntry 38}

 atpcFallbackTimer  OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-write
     STATUS current
     DESCRIPTION
        "Specifies the timer for output power fall back (# of seconds)"
     ::= { ctEntry 39}

 atpcFallbackOutputPower  OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The ATPC fallback output power"
            ::= { ctEntry 40}

    xpicStatus  OBJECT-TYPE
            SYNTAX XpicMimoTC
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Status of the XPIC function."
            ::= { ctEntry 41}

    mimoStatus  OBJECT-TYPE
           SYNTAX XpicMimoTC
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
            "Status of the MIMO function."
           ::= { ctEntry 42}

    actualSnir  OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
              "Actual signal to noise plus interference ratio (dB)."
            ::= { ctEntry 43}

    actualXpi  OBJECT-TYPE
           SYNTAX OCTET STRING
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
             "The carrier to cross-polar interference level (dBc)."
           ::= { ctEntry 44}

    actualSi  OBJECT-TYPE
           SYNTAX OCTET STRING
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
             "Spatial interference between the CTs when MIMO is configured."
           ::= { ctEntry 45}

    actualTxCapacity  OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
         "Actual capacity supported by the carrier termination."
        ::= { ctEntry 46}

    licensedCapacity  OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
      "Wanted or installed license for the capacity allowed for the carrier termination."
     ::= { ctEntry 47}

    availableMinCapacity  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
       "Minimum capacity possible to use. Given by the selected frame-id (kbit/s)"
      ::= { ctEntry 48}

    availableMaxCapacity  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
       "Maximum capacity possible to use. Given by the selected frame-id (kbit/s)"
      ::= { ctEntry 49}

    selectedMinCapacity  OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
      "Selected minimum capacity, derived from selected minimum ACM (kbit/s)"
     ::= { ctEntry 50}

    selectedMaxCapacity  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
       "Selected maximum capacity, derived from selected maximum ACM (kbit/s)"
      ::= { ctEntry 51}

    wantedLicensedCapacity  OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)"
      ::= { ctEntry 52}

    availableMinAcm  OBJECT-TYPE
     SYNTAX AcmTC
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
      "Minimum ACM possible to use, given by the selected frame id."
     ::= { ctEntry 53}

    availableMaxAcm  OBJECT-TYPE
      SYNTAX AcmTC
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
       "Maximum ACM possible to use, given by the selected frame id"
      ::= { ctEntry 54}

    selectedMinAcm  OBJECT-TYPE
      SYNTAX AcmTC
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
      ::= { ctEntry 55}

    selectedMaxAcm  OBJECT-TYPE
      SYNTAX AcmTC
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
      ::= { ctEntry 56}

     actualRxAcmTC  OBJECT-TYPE
     SYNTAX AcmTC
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
      "Actual rx modulation and coding"
     ::= { ctEntry 57}

 actualTxAcmTC  OBJECT-TYPE
     SYNTAX AcmTC
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
      "Actual tx modulation and coding"
     ::= { ctEntry 58}

    alignmentMode  OBJECT-TYPE
      SYNTAX EnableStatusTC
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
       "Enable or disable the alignment mode"
      ::= { ctEntry 59}

    rfLoop  OBJECT-TYPE
     SYNTAX EnableStatusTC
     MAX-ACCESS read-write
     STATUS current
     DESCRIPTION
      "Enable or disable the rf loop"
     ::= { ctEntry 60}


  ---
  ---The definition of rltTable
  ---   
  rltTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF RltEntry
      MAX-ACCESS  not-accessible
      STATUS current
      DESCRIPTION
              "A table of RLT Table entries."
          ::= { ptRadioLink 3 }

  rltEntry OBJECT-TYPE
          SYNTAX      RltEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                    "An entry of RLT application."
          AUGMENTS   { ifEntry }
          ::= { rltTable 1 }

  RltEntry ::=
          SEQUENCE {
                    rltDistinguishedName   OCTET STRING,
                    neIpAddress            IpAddress,
                    neIpv6Address          InetAddressIPv6,
                    neName                 OCTET STRING,
                    neType                 INTEGER,
                    id                     OCTET STRING, 
                    rltStatus              INTEGER,
                    mode                   INTEGER,
                    actualTxTotalCapacity  Integer32,
                    limitedTotalCapacity   Integer32,
                    protectionStatus       INTEGER,
                    revertiveWaitToRestore Integer32,
                    revertivePreferredTx   INTEGER,
                    protectionSwitchMode   INTEGER,
                    fadeNotificationTimer  Integer32,
                    expectedFarEndId       OCTET STRING,
                    farEndIdCheck          INTEGER,
                    cpriMode               INTEGER,
                    cpriStatus             INTEGER,
                    manualSwitch           INTEGER,
                    mlhcOperStatus         INTEGER,
                    mlhcAdminStatus        INTEGER,
                    mlhcMplsConfig         INTEGER,
                                plcOperStatus          INTEGER,
                                plcAdminStatus         INTEGER
                      }

  rltDistinguishedName OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)"
          ::= { rltEntry 1 }

  neIpAddress OBJECT-TYPE
          SYNTAX      IpAddress
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "NE IP address"
          ::= { rltEntry 2 }

  neIpv6Address OBJECT-TYPE
          SYNTAX      InetAddressIPv6
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
            "NE IP V6 address"
          ::= { rltEntry 3 }

  neName       OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "NE Name"
          ::= { rltEntry 4 } 

  neType       OBJECT-TYPE
                SYNTAX INTEGER
                {
                    unknown(1),
                    mle(2),
                    xfMle(3),
                    tn(4),
                    cn(5),
                    pt(6)
                }     
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "NE Type"
          ::= { rltEntry 5 }

  id      OBJECT-TYPE
                SYNTAX OCTET STRING
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "User defined id of the radio link terminal"
                ::= { rltEntry 6}

  rltStatus  OBJECT-TYPE
                SYNTAX INTEGER
                {
                    down(1),
                    up(2),
                    na(3),
                    unknown(4),
                    degraded(5)
                }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "The status of the radio link terminal"
          ::= { rltEntry 7}

    mode    OBJECT-TYPE
          SYNTAX INTEGER
          {
              mode1plus0(1),
            mode1plus1CSB(2),
            mode1plus1RLP(3),
            mode2plus0RLB(4),
            mode2plus1CSB(5),
            mode2plus1RLP(6),
            mode2plus2CSB(7),
            mode2plus2RLP(8),
            mode3plus0RLB(9),
            mode4plus0RLB(10),
            notAvailable11(11),
            notAvailable12(12),
            notAvailable13(13),
            notAvailable14(14),
            mode3plus1RLP(15),
            mode3plus2RLP(16),
            mode3plus3RLP(17),
            mode4plus1RLP(18),
            mode4plus2RLP(19),
            mode4plus3RLP(20),
            mode4plus4RLP(21),
            notAvailable22(22),
            notAvailable23(23),
            notAvailable24(24),
            notAvailable25(25),
            notAvailable26(26),
            notAvailable27(27),
            mode3plus1CSB(28),
            mode3plus2CSB(29),
            mode3plus3CSB(30),
            mode4plus1CSB(31),
            mode4plus2CSB(32),
            mode4plus3CSB(33),
            mode4plus4CSB(34),
            unknown(35)
          }
          MAX-ACCESS read-write
          STATUS current
          DESCRIPTION
            "The status of the radio link terminal"
          ::= { rltEntry 8}

  actualTxTotalCapacity OBJECT-TYPE
          SYNTAX      Integer32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                  "Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination.
                  Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment."
          ::= { rltEntry 9 }

  limitedTotalCapacity OBJECT-TYPE
                SYNTAX      Integer32
                MAX-ACCESS  read-only
                STATUS      current
                DESCRIPTION
                    "Maximum total capacity allowed by the current configuration and installed licenses.
                    Aggregated from the constituent carrier termination values."
                ::= { rltEntry 10 }


  protectionStatus OBJECT-TYPE
                SYNTAX INTEGER
                {
                    unprotected(1),
                    protected(2),
                    unableToProtect(3),
                    unknown(4)
                }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "Status of a protected node."
                ::= { rltEntry 11}

  revertiveWaitToRestore OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                "The time, in number of seconds, to wait before switching back to the preferred Tx."
                ::= { rltEntry 12}

  revertivePreferredTx OBJECT-TYPE
                SYNTAX INTEGER
                {
                    ct11(1),
                    ct12(2),
                    ct21(3),
                    ct22(4),
                    notApplicable(5),
                    unknown(6)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "The preferred carrier termination transmitter."
                ::= { rltEntry 13}



  protectionSwitchMode OBJECT-TYPE
                SYNTAX INTEGER
                {
                    auto(1),
                    manual(2),
                    autoAndRevertive(3),
                    unknown(4),
                    notApplicable(5)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    ".The mode in which the switching mechanism is configured"
                ::= { rltEntry 14}


  fadeNotificationTimer OBJECT-TYPE
                SYNTAX Integer32
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "Notification is sent if fading is longer than this timer, applicable for protection."
                ::= { rltEntry 15}

  expectedFarEndId OBJECT-TYPE
                SYNTAX      OCTET STRING
                MAX-ACCESS  read-write
                STATUS      current
                DESCRIPTION
                    "Expected id of far-end terminal"
                ::= { rltEntry 16 }

  farEndIdCheck OBJECT-TYPE
                SYNTAX INTEGER
                {
                    enabled(1),
                    disabled(2),
                    unknown(3)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "Enabling of far end id check."
                ::= { rltEntry 17}

  cpriMode OBJECT-TYPE
                SYNTAX INTEGER
                {
                    master(1),
                    slave(2),
                    notApplicable(3),
                    unknown(4)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "Set the mode of the CPRI front-haul product."
                ::= { rltEntry 18}

  cpriStatus OBJECT-TYPE
                SYNTAX INTEGER
                {
                    idle(1),
                    waitingOnRtcSync(2),
                    waitingOnCpri(3),
                    waitingOnRxRequest(4),
                    waitingOnTxRequest(5),
                    inSync(6),
                    unknown(7)
                }
                MAX-ACCESS read-only
                STATUS current
                DESCRIPTION
                    "The status of the CPRI front-haul product."
                ::= { rltEntry 19}

  manualSwitch OBJECT-TYPE
                SYNTAX INTEGER
                {
              ct11(1),
              ct12(2),
              ct21(3),
              ct22(4),
              notApplicable(5),
              unknown(6)
                }
                MAX-ACCESS read-write
                STATUS current
                DESCRIPTION
                    "Manual switch of protected carrier termination transmitter."
                ::= { rltEntry 20}  

  mlhcOperStatus  OBJECT-TYPE
              SYNTAX INTEGER
              {
                up(1),
                down(2),
                unknown(3)
              }
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
              "Operative status of multi layer header compression."
              ::= { rltEntry 21}

  mlhcAdminStatus  OBJECT-TYPE
              SYNTAX INTEGER
              {
                off(1),
                on(2),
                unknown(3)
              }
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
              "Administrative status of multi layer header compression."
              ::= { rltEntry 22}

  mlhcMplsConfig  OBJECT-TYPE
                      SYNTAX INTEGER
                      {
                        controlWord(1),
                        l2(2),
                        l3(3),
                        mplsOnly(4),
                        unknown(5)
                      }
                      MAX-ACCESS read-write
                      STATUS current
                      DESCRIPTION
                      "MLHC/MPLS configuration."
                      ::= { rltEntry 23}

  plcOperStatus  OBJECT-TYPE
                      SYNTAX INTEGER
                      {
                        up(1),
                        down(2),
                        unknown(3)
                      }
                      MAX-ACCESS read-only
                      STATUS current
                      DESCRIPTION
                      "Operative status of payload compression."
                      ::= { rltEntry 24}

  plcAdminStatus  OBJECT-TYPE
                      SYNTAX INTEGER
                      {
                        off(1),
                        on(2),
                        unknown(3)
                      }
                      MAX-ACCESS read-write
                      STATUS current
                      DESCRIPTION
                      "Administrative status of payload compression."
                      ::= { rltEntry 25}
  ---
  ---The definition of ct826ContinuousTable
  ---
ctG826ContinuousTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF CtG826ContinuousEntry
      MAX-ACCESS  not-accessible
      STATUS current
      DESCRIPTION
              "A table of CT G826 Performance Continuous counters entries.
              The counters are reset by ctG826Reset"
          ::= { ctPerformance 1 }

  ctG826ContinuousEntry OBJECT-TYPE
          SYNTAX      CtG826ContinuousEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                    "An entry of CT G826 Performance Continuous counters."
          AUGMENTS   { ifEntry }
          ::= { ctG826ContinuousTable 1 }

  CtG826ContinuousEntry ::=
          SEQUENCE {
              ctG826TimeElapsed        Counter32,
              ctBBE                    Counter32,
              ctBBER                   OCTET STRING,
              ctES                     Counter32,
              ctESR                    OCTET STRING,
              ctSES                    Counter32,
              ctSESR                   OCTET STRING,
              ctBB                     OCTET STRING,
              ctUAS                    Counter32,
              ctG826Reset              INTEGER
          }

  ctG826TimeElapsed OBJECT-TYPE
          SYNTAX      Counter32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Time elapsed in seconds since last PMReset"
          ::= { ctG826ContinuousEntry 1 }

  ctBBE   OBJECT-TYPE
          SYNTAX      Counter32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Background Block Errors"
          ::= { ctG826ContinuousEntry 2 }

  ctBBER  OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Background Block Errors Ratio"
          ::= { ctG826ContinuousEntry 3 } 

  ctES    OBJECT-TYPE
          SYNTAX      Counter32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Error seconds"
          ::= { ctG826ContinuousEntry 4 } 

  ctESR   OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Error seconds Ratio"
          ::= { ctG826ContinuousEntry 5 }

  ctSES   OBJECT-TYPE
          SYNTAX      Counter32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Severely error seconds"
          ::= { ctG826ContinuousEntry 6 }

  ctSESR  OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Severely error seconds Ratio"
          ::= { ctG826ContinuousEntry 7 } 

  ctBB    OBJECT-TYPE
          SYNTAX      OCTET STRING
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Background blocks"
          ::= { ctG826ContinuousEntry 8 } 

  ctUAS   OBJECT-TYPE
          SYNTAX      Counter32
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
              "Unavailable seconds "
          ::= { ctG826ContinuousEntry 9 }

  ctG826Reset OBJECT-TYPE
          SYNTAX INTEGER
          {
              other(1),
              noReset(2),
              reset(3)
          }
          MAX-ACCESS  read-write
          STATUS      current
          DESCRIPTION
              "Reset the continuous PM counters"
          ::= { ctG826ContinuousEntry 10 }


---
---The definition of ctG826Current15mTable
---   
ctG826Current15mTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF CtG826Current15mEntry
        MAX-ACCESS  not-accessible
        STATUS current
        DESCRIPTION
                "A table of CT Performance G826 15 m current counters Table entries."
            ::= { ctPerformance 2 }

  ctG826Current15mEntry OBJECT-TYPE
            SYNTAX      CtG826Current15mEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                      "An entry of CT Performance G826 15 m current Table counters."
            AUGMENTS   { ifEntry }
            ::= { ctG826Current15mTable 1 }

  CtG826Current15mEntry ::=
            SEQUENCE {
                ctG826Current15mTimeElapsed   Counter32,
                ctCurrent15mBBE           Counter32,
              ctCurrent15mBBER          OCTET STRING,
              ctCurrent15mES            Counter32,
              ctCurrent15mESR           OCTET STRING,
              ctCurrent15mSES           Counter32,
              ctCurrent15mSESR          OCTET STRING,
              ctCurrent15mBB            Counter32,
              ctCurrent15mUAS           Counter32
                        }

  ctG826Current15mTimeElapsed OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time elapsed in seconds since last PMReset"
    ::= { ctG826Current15mEntry 1 }

  ctCurrent15mBBE OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Background Block Errors"
    ::= { ctG826Current15mEntry 2 }

  ctCurrent15mBBER       OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Background Block Errors Ratio"
    ::= { ctG826Current15mEntry 3 } 

  ctCurrent15mES  OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Error seconds"
    ::= { ctG826Current15mEntry 4 } 

  ctCurrent15mESR OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Error seconds Ratio"
    ::= { ctG826Current15mEntry 5 }

  ctCurrent15mSES OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Severely error seconds"
    ::= { ctG826Current15mEntry 6 }

  ctCurrent15mSESR       OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Severely error seconds Ratio"
    ::= { ctG826Current15mEntry 7 } 

  ctCurrent15mBB       OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Background blocks"
    ::= { ctG826Current15mEntry 8 } 

  ctCurrent15mUAS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Unavailable seconds "
    ::= { ctG826Current15mEntry 9 }

---
---The definition of ctG826Current24hTable
---   
ctG826Current24hTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF CtG826Current24hEntry
      MAX-ACCESS  not-accessible
      STATUS current
      DESCRIPTION
              "A table of CT Performance G826 Current 24h counters entries."
          ::= { ctPerformance 3 }

  ctG826Current24hEntry OBJECT-TYPE
      SYNTAX      CtG826Current24hEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
               "An entry of CT Performance G826 Current 24 h counters."
      AUGMENTS   { ifEntry }
        ::= { ctG826Current24hTable 1 }

      CtG826Current24hEntry ::=
              SEQUENCE {
                    ctG826Current24hTimeElapsed Counter32,
                  ctCurrent24hBBE             Counter32,
                  ctCurrent24hBBER            OCTET STRING,
                  ctCurrent24hES              Counter32,
                  ctCurrent24hESR             OCTET STRING,
                  ctCurrent24hSES             Counter32,
                  ctCurrent24hSESR            OCTET STRING,
                  ctCurrent24hBB              Counter32,
                  ctCurrent24hUAS             Counter32
              }

  ctG826Current24hTimeElapsed OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Time elapsed in seconds since last PMReset"
      ::= { ctG826Current24hEntry 1 }

  ctCurrent24hBBE OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Background Block Errors"
      ::= { ctG826Current24hEntry 2 }

  ctCurrent24hBBER       OBJECT-TYPE
      SYNTAX      OCTET STRING
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Background Block Errors Ratio"
      ::= { ctG826Current24hEntry 3 } 

  ctCurrent24hES  OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Error seconds"
      ::= { ctG826Current24hEntry 4 } 

  ctCurrent24hESR OBJECT-TYPE
      SYNTAX      OCTET STRING
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Error seconds Ratio"
      ::= { ctG826Current24hEntry 5 }

  ctCurrent24hSES OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Severely error seconds"
      ::= { ctG826Current24hEntry 6 }

  ctCurrent24hSESR       OBJECT-TYPE
      SYNTAX      OCTET STRING
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Severely error seconds Ratio"
      ::= { ctG826Current24hEntry 7 } 

  ctCurrent24hBB       OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Background blocks"
      ::= { ctG826Current24hEntry 8 } 

  ctCurrent24hUAS OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Unavailable seconds "
      ::= { ctG826Current24hEntry 9 }

--
-- Conformance
--

    ptRadioLinkCompliances OBJECT IDENTIFIER ::= { ptRadioLinkConformance 1 }
    ptRadioLinkGroups      OBJECT IDENTIFIER ::= { ptRadioLinkConformance 2 }

    ptRadioLinkFullCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
            "The compliance statement for SNMP entities which implement everything."
        MODULE -- This Module
        MANDATORY-GROUPS { ptRadioLinkCompleteGroup}
        ::= { ptRadioLinkCompliances 1 }

    ptRadioLinkCompleteGroup OBJECT-GROUP
        OBJECTS
        {
            actualInputPower,
            actualOutputPower,
            actualRxAcm,
            actualRxAcmTC,
            actualSi,
            actualSnir,
            actualTxAcm,
            actualTxAcmTC,
            actualTxCapacity,
            actualTxTotalCapacity,
            actualXpi,
            alignmentMode,
            atpcFallback,
            atpcFallbackTimer,
            atpcFallbackOutputPower,
            autoFreqSelectedChannel,
            autoFreqSelection,
            autoFreqSelectionStatus,
            availableMaxAcm,
            availableMaxCapacity,
            availableMaxOutputPower,
            availableMinAcm,
            availableMinCapacity,
            availableMinOutputPower,
            availableOutputPowerType,
            berAlarmThreshold,
            carrierId,
            channelSpacing,
            cpriMode,
            cpriStatus,
            ctDistinguishedName,
            ctCurrent15mBB,
            ctCurrent15mBBE,
            ctCurrent15mBBER,
            ctCurrent15mES,
            ctCurrent15mESR,
            ctCurrent15mSES,
            ctCurrent15mSESR,
            ctCurrent15mUAS,
            ctG826Current15mTimeElapsed,
            ctCurrent24hBB,
            ctCurrent24hBBE,
            ctCurrent24hBBER,
            ctCurrent24hES,
            ctCurrent24hESR,
            ctCurrent24hSES,
            ctCurrent24hSESR,
            ctCurrent24hUAS,
            ctG826Current24hTimeElapsed,
            ctBB,
            ctBBE,
            ctBBER,
            ctES,
            ctESR,
            ctG826Reset,
            ctSES,
            ctSESR,
            ctG826TimeElapsed,
            ctUAS,
            ctStatus,
            description,
            duplexConfig,
            duplexDistance,
            duplexType,
            expectedFarEndId,
            fadeNotificationTimer,
            farEndIdCheck,
            frameId,
            frequencyStepSize,
            id,
            inputPowerAlarmThreshold,
            licensedCapacity,
            limitedTotalCapacity,
            manualSwitch,
            maxRxFrequency,
            maxTxFrequency,
            mimoStatus,
            minRxFrequency,
            minTxFrequency,
            mlhcAdminStatus,
            mlhcMplsConfig,
            mlhcOperStatus,
            plcAdminStatus,
            plcOperStatus,
            mode,
            neIpAddress,
            neIpv6Address,
            neName,
            neType,
            plannedAlignmentInputPower,
            polarization,
            protectionStatus,
            protectionSwitchMode,
            referenceSec,
            revertivePreferredTx,
            revertiveWaitToRestore,
            rfLoop,
            rltDistinguishedName,
            rltStatus,
            rxFrequency,
            selectedMaxAcm,
            selectedMaxCapacity,
            selectedMaxOutputPower,
            selectedMinAcm,
            selectedMinCapacity,
            selectedMinOutputPower,
            selectedOutputPowerType,
            targetInputPowerFarEnd,
            txAdminStatus,
            txFrequency,
            txOperStatus,
            wantedLicensedCapacity,
            xpicStatus
        }
        STATUS current
        DESCRIPTION
            "A collection of all current objects in this MIB module."
        ::= { ptRadioLinkGroups 1 }


END