-- RBN-ENVMON-MIB    Environmental Monitor MIB
--
-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB
-- All rights reserved.
-- 
-- *****************************************************************

RBN-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    NOTIFICATION-TYPE,
    Unsigned32,
    Integer32
        FROM SNMPv2-SMI
    DisplayString,
    TruthValue,
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC
    MODULE-COMPLIANCE,
    OBJECT-GROUP,
    NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    entPhysicalIndex
        FROM ENTITY-MIB
    rbnMgmt
        FROM RBN-SMI;

rbnEnvMonMIB MODULE-IDENTITY
        LAST-UPDATED    "201210030000Z" -- October 3, 2012
    ORGANIZATION    "Ericsson AB."
    CONTACT-INFO
        "    Ericsson AB.

        Postal:    100 Headquarters Dr.
            San Jose, CA  95134
            USA

         Phone:    +1 408 750 5000
           Fax: +1 408 750 5599

        "
    DESCRIPTION
        "The MIB used to genericially manage Environmental
        Monitor functionality on network devices."
               
        REVISION        "201210030000Z" -- October 3, 2012
        DESCRIPTION
                "Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed."

        REVISION        "201101191800Z" -- Jan 19, 2011
        DESCRIPTION
                "Update CONTACT-INFO & ORGANIZATION. "

        REVISION        "201011110000Z" -- Nov 11, 2010
        DESCRIPTION
                "Add new Table rbnEntityTempSensorTable. This will display 
                the TempSensor Details for all the entities. "

    REVISION    "200601160000Z" -- January 16, 2006
    DESCRIPTION
        "Add textual convention RbnFanSpeed.  Add new OIDs:
            rbnFanUnitID
            rbnFanUnitDescr
            rbnFanSpeedCurrent
            rbnEnvMonFanSpeedObjectGroup
            rbnEnvMonMIBComplianceV4
        "
    REVISION    "200206050000Z" -- June 5, 2002
    DESCRIPTION
        "Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
        ranges on Integer32, and size for DisplayString types.
        Restore the incorrectly deprecated OIDs to current, since they
        are still supported."
    REVISION        "200107250000Z" -- July 25, 2001
    DESCRIPTION
        "Added new OIDs:
            rbnFanStatus
            rbnPowerStatus
            rbnFanStatusChange
            rbnPowerStatusChange
            rbnEnvMonMIBObjectGroupV2
            rbnEnvMonMIBNotificationGroupV2
            rbnEnvMonMIBComplianceV3
         Deprecated the OIDs:
            rbnFanFail
            rbnPowerFail
            rbnFanFailChange
            rbnPowerFailChange
            rbnEnvMonMIBObjectGroup
            rbnEnvMonMIBNotificationGroup
            rbnEnvMonMIBComplianceV2
        "
    REVISION    "200004240000Z" -- May 24, 2000
    DESCRIPTION
        "Added voltage and temperature sensor tables."

    REVISION    "199903100000Z" -- Mar 10, 1999
    DESCRIPTION
            "Initial version."
    ::= { rbnMgmt 4 }

rbnEnvMonMIBNotifications OBJECT IDENTIFIER
    ::= { rbnEnvMonMIB 0 }

rbnEnvMonMIBObjects OBJECT IDENTIFIER
    ::= { rbnEnvMonMIB 1 }

rbnEnvMonMIBConformance OBJECT IDENTIFIER
    ::= { rbnEnvMonMIB 2 }


-- Textual Conventions

RbnVoltage ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Represents a voltage value. The value is millivolts.
         For example, a voltage of 5.5V would be represented
         by the value 5500."
    SYNTAX       Unsigned32 (0..50000)

RbnTemperature ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "Represents a temperature, in degrees Celsius. In the
         unlikely event that the temperature to be reported is
         less than 0 degrees Celsius, a value of 0 will be
         used. Likewise, if the temperature is greater than
         100, a value of 100 will be used."
    SYNTAX       Unsigned32 (0..100)

RbnFanSpeed ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Represents a fan speed value in units of Revolutions Per
        Minute(RPM)."
    SYNTAX       Unsigned32

-- MIB Objects

rbnFanStatusTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF RbnFanStatusEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "This table contains one row per fan test point.
        Note that there is not necessarily a one-to-one
        relationship between fan test points and fan
        assemblies; a single test point may be used to
        monitor the status of multiple fans."
    ::= { rbnEnvMonMIBObjects 1 }

rbnFanStatusEntry OBJECT-TYPE
    SYNTAX        RbnFanStatusEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "Information about a particular fan test point"
    INDEX    { rbnFanIndex }
    ::= { rbnFanStatusTable 1 }

RbnFanStatusEntry ::= SEQUENCE {
    rbnFanIndex    Integer32,
    rbnFanDescr    DisplayString,
    rbnFanFail    TruthValue,
    rbnFanStatus    INTEGER
}

rbnFanIndex OBJECT-TYPE
    SYNTAX        Integer32(1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "The index of a fan test point."
    ::= { rbnFanStatusEntry 1 }

rbnFanDescr OBJECT-TYPE
    SYNTAX        DisplayString(SIZE(0..32))
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The description of a fan test point.  If an instance of
        this object is associated with a single fan assembly,
        then the value of this object should be the same as the
        name by which the assembly is normally referenced.  If
        an instance is associated with multiple fan assemblies,
        then the value of this object should contain the names
        of all of the fan assemblies being monitored."
    ::= { rbnFanStatusEntry 2 }

rbnFanFail OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS  read-only
    STATUS        deprecated 
    DESCRIPTION
        "The status of a fan test point.  If an instance of
        this object has the value true, then a fan monitored
        by the test point has failed.  If an instance of
        this object has the value false, then the fan (or fans)
        monitored by the test point are operational."
    ::= { rbnFanStatusEntry 3 }

rbnFanStatus OBJECT-TYPE
    SYNTAX        INTEGER {
            normal(1),
            failed(2),
            absent(3),
            unknown(4)
            }
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The status of a fan test point.  If an instance of
        this object has the value normal, then the fan (or 
        fans) monitored by the test point is operational.  If
        an instance of this object has the value failed, then 
        the fan (or fans) monitored by the test point has 
        failed. If an instance of this object has the value 
        absent, then the fan (or fans) monitored by this test 
        point is not present. If an instance of this object has
        the value unknown, then the test point is unable to
        monitor the fan (or fans)."
    ::= { rbnFanStatusEntry 4 }

rbnPowerStatusTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF RbnPowerStatusEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "This table contains one row per power test point.
        Note that there is not necessarily a one-to-one
        relationship between power test points and power
        supply assemblies; a single test point may be used
        to monitor the status of multiple power supplies."
    ::= { rbnEnvMonMIBObjects 2 }

rbnPowerStatusEntry OBJECT-TYPE
    SYNTAX        RbnPowerStatusEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "Information about a particular power test point"
    INDEX    { rbnPowerIndex }
    ::= { rbnPowerStatusTable 1 }

RbnPowerStatusEntry ::= SEQUENCE {
    rbnPowerIndex    Integer32,
    rbnPowerDescr    DisplayString,
    rbnPowerFail    TruthValue,
    rbnPowerStatus    INTEGER
}

rbnPowerIndex OBJECT-TYPE
    SYNTAX        Integer32(1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "The index of a power test point."
    ::= { rbnPowerStatusEntry 1 }

rbnPowerDescr OBJECT-TYPE
    SYNTAX        DisplayString(SIZE(0..32))
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The description of a power supply test point.  If an
        instance of this object is associated with a single
        power supply assembly, then the value of this object
        should be the same as the name by which the assembly
        is normally referenced.  If an instance is associated
        with multiple power supply assemblies, then the value
        of this object should contain the names of all of the
        power supply assemblies being monitored."
    ::= { rbnPowerStatusEntry 2 }

rbnPowerFail OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS  read-only
    STATUS        deprecated 
    DESCRIPTION
        "The status of a power test point.  If an instance of
        this object has the value true, then a power supply
        monitored by the test point has failed.  If an instance
        of this object has the value false, then the power
        supply (or supplies) monitored by the test point are
        operational."
    ::= { rbnPowerStatusEntry 3 }

rbnPowerStatus OBJECT-TYPE
    SYNTAX        INTEGER {
            normal(1),
            failed(2),
            absent(3),
            unknown(4)
            }
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The status of a power test point.  If an instance of
        this object has the value normal, then the power 
        supply (or supplies) monitored by the test point is 
        operational.  If an instance of this object has the 
        value failed, then the power supply (or supplies)
        monitored by the test point has failed. If an instance
        of this object has the value absent, then the power
        supply (or supplies) monitored by this test point is 
        not present. If an instance of this object has
        the value unknown, then the test point is unable to
        monitor the power supply (or supplies)."
    ::= { rbnPowerStatusEntry 4 }

rbnVoltageSensorTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF RbnVoltageSensorEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "This table contains one row per voltage test point.
         Each physical entity (e.g. cards) in the system may
         contain zero or more voltage test points."
    ::= { rbnEnvMonMIBObjects 3 }

rbnVoltageSensorEntry OBJECT-TYPE
    SYNTAX    RbnVoltageSensorEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "Information about a particular voltage test point."
    INDEX    { entPhysicalIndex, rbnVoltageIndex }
    ::= { rbnVoltageSensorTable 1 }

RbnVoltageSensorEntry ::= SEQUENCE {
    rbnVoltageIndex   Integer32,
    rbnVoltageDescr   DisplayString,
    rbnVoltageDesired RbnVoltage,
    rbnVoltageCurrent RbnVoltage
}

rbnVoltageIndex OBJECT-TYPE
    SYNTAX      Integer32(1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "An arbitrary value which uniquely identifies a
         voltage test point on a particular physical entity.
         Index values for different test points are not
         necessarily contiguous."
    ::= { rbnVoltageSensorEntry 1 }

rbnVoltageDescr OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..48))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The description of a voltage test point. Typically
         an instance of this object will hold a user-friendly
         description of the physical entity and the level of
         voltage being monitored by this test point."
    ::= { rbnVoltageSensorEntry 2 }

rbnVoltageDesired OBJECT-TYPE
    SYNTAX      RbnVoltage
    UNITS        "millivolts"
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The desired voltage level for this test point. If
         the monitored voltage level (rbnVoltageCurrent) is
         equal to this value, then the system is performing
         as designed."
    ::= { rbnVoltageSensorEntry 3 }

rbnVoltageCurrent OBJECT-TYPE
    SYNTAX      RbnVoltage
    UNITS        "millivolts"
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The current voltage level at this test point."
    ::= { rbnVoltageSensorEntry 4 }

rbnCpuTempSensorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RbnCpuTempSensorEntry
    MAX-ACCESS  not-accessible
    STATUS        deprecated 
    DESCRIPTION
        "This table contains one row per CPU temperature
         sensor. Each physical entity in the system may have
         zero or more CPUs. Each of those CPUs that has a
         temperature sensor will show up here."
    ::= { rbnEnvMonMIBObjects 4 }

rbnCpuTempSensorEntry OBJECT-TYPE
    SYNTAX      RbnCpuTempSensorEntry
    MAX-ACCESS  not-accessible
    STATUS        deprecated 
    DESCRIPTION
        "Information about a particular CPU temperature test
         point."
    INDEX   { entPhysicalIndex, rbnCpuTempIndex }
    ::= { rbnCpuTempSensorTable 1 }

RbnCpuTempSensorEntry ::= SEQUENCE {
    rbnCpuTempIndex   Integer32,
    rbnCpuTempDescr   DisplayString,
    rbnCpuTempCurrent RbnTemperature
}

rbnCpuTempIndex OBJECT-TYPE
    SYNTAX      Integer32(1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS        deprecated
    DESCRIPTION
        "An arbitrary value which uniquely identifies a CPU on
         a particular physical entity.  Index values for
         different CPUs are not necessarily contiguous."
    ::= { rbnCpuTempSensorEntry 1 }

rbnCpuTempDescr OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..48))
    MAX-ACCESS  read-only
    STATUS        deprecated
    DESCRIPTION
        "The description of a CPU temperature test
         point. Typically an instance of this object will hold
         a user-friendly description of the physical entity
         and a description of the CPU being monitored by this
         test point."
    ::= { rbnCpuTempSensorEntry 2 }

rbnCpuTempCurrent OBJECT-TYPE
    SYNTAX      RbnTemperature
    UNITS        "degrees"
    MAX-ACCESS  read-only
    STATUS        deprecated
    DESCRIPTION
        "The current temperature of this CPU."
    ::= { rbnCpuTempSensorEntry 3 }

rbnFanSpeedTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF RbnFanSpeedEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "This table contains one row per fan unit within a fan
        test point."
    ::= { rbnEnvMonMIBObjects 5 }

rbnFanSpeedEntry OBJECT-TYPE
    SYNTAX        RbnFanSpeedEntry
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "Information about a particular fan unit within a fan
                test point."
    INDEX    { rbnFanIndex, rbnFanUnitID }
    ::= { rbnFanSpeedTable 1 }

RbnFanSpeedEntry ::= SEQUENCE {
    rbnFanUnitID        Integer32,
    rbnFanUnitDescr        DisplayString,
    rbnFanSpeedCurrent  RbnFanSpeed
}

rbnFanUnitID OBJECT-TYPE
    SYNTAX        Integer32(1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS        current
    DESCRIPTION
        "This is the fan identification number that describes the
        specific location of the fan unit within a fan test point."
    ::= { rbnFanSpeedEntry 1 }

rbnFanUnitDescr OBJECT-TYPE
    SYNTAX        DisplayString(SIZE(0..32))
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The description of the fan unit within a fan test point."
    ::= { rbnFanSpeedEntry 2 }

rbnFanSpeedCurrent OBJECT-TYPE
    SYNTAX        RbnFanSpeed
    MAX-ACCESS  read-only
    STATUS        current
    DESCRIPTION
        "The current speed of this fan unit."
    ::= { rbnFanSpeedEntry 3 }

rbnEntityTempSensorTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF RbnEntityTempSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "This table contains one row per temperature
                 sensor on the physical entity."
        ::= { rbnEnvMonMIBObjects 6 }

rbnEntityTempSensorEntry OBJECT-TYPE
        SYNTAX      RbnEntityTempSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Information about a particular temperature test
                 point."
        INDEX   { entPhysicalIndex, rbnEntityTempIndex }
        ::= { rbnEntityTempSensorTable 1 }

RbnEntityTempSensorEntry ::= SEQUENCE {
        rbnEntityTempIndex   Integer32,
        rbnEntityTempDescr   DisplayString,
        rbnEntityTempCurrent RbnTemperature
}

rbnEntityTempIndex OBJECT-TYPE
        SYNTAX      Integer32(1..2147483647)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "An arbitrary value which uniquely identifies a
                 particular physical entity.  Index values are 
                 not necessarily contiguous."
        ::= { rbnEntityTempSensorEntry 1 }

rbnEntityTempDescr OBJECT-TYPE
        SYNTAX      DisplayString (SIZE (0..48))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The description of a temperature test
                 point. Typically an instance of this object will hold
                 a user-friendly description of the physical entity
                 being monitored by this test point."
        ::= { rbnEntityTempSensorEntry 2 }

rbnEntityTempCurrent OBJECT-TYPE
        SYNTAX      RbnTemperature
        UNITS       "degrees Celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The current temperature of this entity in degrees Celsius."
        ::= { rbnEntityTempSensorEntry 3 }

-- Notifications

rbnFanFailChange NOTIFICATION-TYPE
    OBJECTS        { rbnFanFail }
    STATUS        deprecated 
    DESCRIPTION
        "A rbnFanFailChange notification signifies
        that the value of an instance of rbnFanFail
        has changed."
    ::= { rbnEnvMonMIBNotifications 1 }

rbnPowerFailChange NOTIFICATION-TYPE
    OBJECTS        { rbnPowerFail }
    STATUS        deprecated 
    DESCRIPTION
        "A rbnPowerFailChange notification signifies
        that the value of an instance of rbnPowerFail
        has changed"
    ::= { rbnEnvMonMIBNotifications 2 }

rbnFanStatusChange NOTIFICATION-TYPE
    OBJECTS        { rbnFanStatus }
    STATUS        current
    DESCRIPTION
        "A rbnFanStatusChange notification signifies
        that the value of an instance of rbnFanStatus
        has changed."
    ::= { rbnEnvMonMIBNotifications 3 }

rbnPowerStatusChange NOTIFICATION-TYPE
    OBJECTS        { rbnPowerStatus }
    STATUS        current
    DESCRIPTION
        "A rbnPowerStatusChange notification signifies
        that the value of an instance of rbnPowerStatus
        has changed"
    ::= { rbnEnvMonMIBNotifications 4 }

-- Conformance Statements

rbnEnvMonMIBGroups OBJECT IDENTIFIER
    ::= { rbnEnvMonMIBConformance 1 }

rbnEnvMonMIBCompliances OBJECT IDENTIFIER
    ::= { rbnEnvMonMIBConformance 2 }

rbnEnvMonMIBObjectGroup OBJECT-GROUP
    OBJECTS        {    rbnFanDescr, rbnFanFail,
            rbnPowerDescr, rbnPowerFail
            }
    STATUS        deprecated 
    DESCRIPTION
        "A collection of objects providing
        environmental monitor information."
    ::= { rbnEnvMonMIBGroups 1 }

rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS {    rbnFanFailChange,
            rbnPowerFailChange
            }
    STATUS        deprecated 
    DESCRIPTION
        "A collection of notifications providing
        fan and power environmental monitor information."
    ::= { rbnEnvMonMIBGroups 2 }

rbnEnvMonVoltageObjectGroup OBJECT-GROUP
    OBJECTS        {    rbnVoltageDescr, rbnVoltageDesired,
            rbnVoltageCurrent
            }
    STATUS        current
    DESCRIPTION
        "A collection of objects providing voltage
        environmental monitor information."
    ::= { rbnEnvMonMIBGroups 3 }

rbnEnvMonTempObjectGroup OBJECT-GROUP
    OBJECTS        {    rbnCpuTempDescr, rbnCpuTempCurrent
            }
    STATUS       deprecated   
    DESCRIPTION
        "A collection of objects providing temperature
        environmental monitor information."
    ::= { rbnEnvMonMIBGroups 4 }

rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP
    OBJECTS        {    rbnFanDescr, rbnFanStatus,
            rbnPowerDescr, rbnPowerStatus
            }
    STATUS        current
    DESCRIPTION
        "A collection of objects providing
        environmental monitor information."
    ::= { rbnEnvMonMIBGroups 5 }

rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
    NOTIFICATIONS {    rbnFanStatusChange,
            rbnPowerStatusChange
            }
    STATUS        current
    DESCRIPTION
        "A collection of notifications providing
        fan and power environmental monitor information."
    ::= { rbnEnvMonMIBGroups 6 }

rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP
    OBJECTS        {    rbnFanUnitDescr, rbnFanSpeedCurrent
            }
    STATUS        current
    DESCRIPTION
        "A collection of objects providing fan speed
        environmental monitor information."
    ::= { rbnEnvMonMIBGroups 7 }

rbnEnvMonEntityObjectGroup OBJECT-GROUP
        OBJECTS     {   rbnEntityTempDescr, rbnEntityTempCurrent
                    }
        STATUS      current
        DESCRIPTION
                "A collection of objects providing fan speed
                environmental monitor information."
        ::= { rbnEnvMonMIBGroups 8 }

rbnEnvMonMIBCompliance MODULE-COMPLIANCE
    STATUS        obsolete
    DESCRIPTION
        "The compliance statement for the EnvMon MIB"
    MODULE        -- this module
    GROUP        rbnEnvMonMIBObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonMIBNotificationGroup
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    ::= { rbnEnvMonMIBCompliances 1 }

rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE
    STATUS        deprecated 
    DESCRIPTION
        "The compliance statement for the EnvMon MIB"

    MODULE        -- this module
    GROUP        rbnEnvMonMIBObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonMIBNotificationGroup
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonVoltageObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system voltages."
    GROUP        rbnEnvMonTempObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system temperatures."
    ::= { rbnEnvMonMIBCompliances 2 }

rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE
    STATUS        deprecated 
    DESCRIPTION
        "The compliance statement for the EnvMon MIB"
    MODULE        -- this module
    GROUP        rbnEnvMonMIBObjectGroupV2
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonMIBNotificationGroupV2
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonVoltageObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system voltages."
    GROUP        rbnEnvMonTempObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system temperatures."
    ::= { rbnEnvMonMIBCompliances 3 }

rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE
    STATUS        deprecated 
    DESCRIPTION
        "The compliance statement for the EnvMon MIB"
    MODULE        -- this module
    GROUP        rbnEnvMonMIBObjectGroupV2
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonMIBNotificationGroupV2
    DESCRIPTION
        "This group is mandatory for devices which contain
        Environmental Monitoring capabilities"
    GROUP        rbnEnvMonVoltageObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system voltages."
    GROUP        rbnEnvMonTempObjectGroup
    DESCRIPTION
        "This group is mandatory for devices which are capable
         of sensing system temperatures."
    GROUP        rbnEnvMonFanSpeedObjectGroup
    DESCRIPTION
        "This group is mandatory for SNMP entities which are
                capable of sensing fan speeds."
    ::= { rbnEnvMonMIBCompliances 4 }


rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE
        STATUS      current
        DESCRIPTION
                "The compliance statement for the EnvMon MIB"
        MODULE      -- this module
        GROUP       rbnEnvMonMIBObjectGroupV2
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities"
        GROUP       rbnEnvMonMIBNotificationGroupV2
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities"
        GROUP       rbnEnvMonVoltageObjectGroup
        DESCRIPTION
                "This group is mandatory for devices which are capable
                 of sensing system voltages."
        GROUP       rbnEnvMonFanSpeedObjectGroup
        DESCRIPTION
                "This group is mandatory for SNMP entities which are
                capable of sensing fan speeds."
        GROUP       rbnEnvMonEntityObjectGroup
        DESCRIPTION
                "This group is mandatory for devices which contain
                Environmental Monitoring capabilities, also applicable to SSE
                card and disks"

        ::= { rbnEnvMonMIBCompliances 5 }

END