librenms/librenms

View on GitHub
mibs/ericsson/RBN-TC

Summary

Maintainability
Test Coverage
-- %DNP% $Id: RBN-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/RBN-TC.my,v $
-- *****************************************************************
-- RBN-TC    Textual Convention MIB
--
-- Copyright (c) 2000, 2002-2009, 2011 Ericsson AB
-- All rights reserved.
-- 
-- *****************************************************************

RBN-TC DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    Integer32, Unsigned32
            FROM SNMPv2-SMI

    TEXTUAL-CONVENTION
            FROM SNMPv2-TC

    rbnModules
            FROM RBN-SMI;


rbnTC MODULE-IDENTITY
    LAST-UPDATED    "201101191800Z" -- Jan 19, 2011
    ORGANIZATION    "Ericsson AB."
    CONTACT-INFO
            "       Ericsson AB.

            Postal: 100 Headquarters Dr
                    San Jose, CA  95134
                    USA

             Phone: +1 408 750 5000
               Fax: +1 408 750 5599
            "
    DESCRIPTION
        "Defines common textual conventions used in RBN mib
        modules."

    REVISION        "201101191800Z" -- Jan 19, 2011
    DESCRIPTION
            "Update CONTACT-INFO & ORGANIZATION. "

    REVISION      "200910201700Z" -- Oct 20, 2009
    DESCRIPTION
        "Added new textual convention: RbnUnsigned64 for read-write
        capable 64 bit integer value."

    REVISION      "200406191700Z" -- June 19, 2004
    DESCRIPTION
        "Added new textual convention: RbnPortMediumType. Correct 
        warnings given by smilint."

    REVISION      "200303171700Z" -- March 17, 2003
    DESCRIPTION
        "Added new textual convention: RbnVidOrUntagged."

    REVISION      "200211110000Z" -- November 11, 2002
    DESCRIPTION
        "Moved definitions of RbnSlot and RbnPort from RBN-PVC-MIB.
        Updated range on RbnSlot and RbnPort."

    REVISION      "200206260000Z" -- June 26, 2002
    DESCRIPTION
        "Updated CONTACT-INFO. Added new textual conventions:
        RbnKBytes and RbnPercentage."

    REVISION      "200007140000Z" -- July 14, 2000
    DESCRIPTION
        "Initial version."
    ::= { rbnModules 2 }


RbnCircuitHandle ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "1d:1d:2x-2x-2x"
    STATUS current
    DESCRIPTION
        "A unique identifier for individual circuits. The string is
        composed of the following:
        
            Octet 1     slot
                  2     port
                  3-8   circuit identifier
        
        slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
        0..n but SE CLI numbers slots/ports 1..n. For example: When the 
        SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
        slot/port 0/1   
        "
    SYNTAX  OCTET STRING (SIZE (8))
    
RbnKBytes ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS current
    DESCRIPTION
        "Storage size, expressed in units of 1024 bytes."
    SYNTAX Integer32 (0..2147483647)

RbnPercentage ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d%"
    STATUS current
    DESCRIPTION
        "This Textual Convention describes an object that stores 
        a whole integer percentage value."
    SYNTAX Integer32 (0..100)    

RbnSlot ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "The chassis slot number.  This is the physical slot
        number as reported in the CLI command 'show hardware'
        on SMS and the CLI command 'show port' on SE."
    SYNTAX  Unsigned32 (0..255)

RbnPort ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "The chassis port number.  This is the physical port
        number as reported in the CLI command 'show hardware'
        on SMS and the CLI command 'show port' on SE."
    SYNTAX  Unsigned32 (0..255)

RbnVidOrUntagged ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION 
        "The twelve-bit VLAN Identifer (VID) used to uniquely
        identify the VLAN to which the frame belongs.  The VID is
        encoded as an unsigned binary number.  An untagged frame
        does not carry any identification of the VLAN to which it
        belongs and is designated with a value of 4096."
    SYNTAX    Integer32 (1..4096) 

RbnPortMediumType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION 
        "Medium type of NAS port."
    SYNTAX    INTEGER {
                    unknown(0),
                    dsl(11),
                    cable(12),
                    wireless(13),
                    satellite(14)
                }

RbnUnsigned64 ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "8d"
    STATUS       current
    DESCRIPTION 
        "Unsigned 64 bit integer value is represented as an
         OCTET STRING.  This allows an unsigned integer value in
         the range 0..18446744073709551615.  

         The octets are ordered with the first octet containing
         the highest ordered bits of the integer and the 8th octet
         containing the lowest ordered bits, corresponding to
         network byte order."
    SYNTAX OCTET STRING (SIZE(8))
    
END