librenms/librenms

View on GitHub
mibs/fortinet/MERU-VOICE-STATISTICS-MIB

Summary

Maintainability
Test Coverage
-- *****************************************************************
-- Meru Networks Enterprise Specific MIB
--
-- Copyright (c) 2005 by Meru Networks
-- All rights reserved
--
-- *****************************************************************

MERU-VOICE-STATISTICS-MIB  DEFINITIONS ::= BEGIN

IMPORTS
    NOTIFICATION-TYPE, 
    OBJECT-TYPE, 
    MODULE-IDENTITY, 
    OBJECT-IDENTITY,
    enterprises, 
    Counter32, 
    Counter64, 
    Gauge32, 
    TimeTicks, 
    IpAddress, 
    Integer32
        FROM SNMPv2-SMI
    Ipv6Address
        FROM IPV6-TC
    TEXTUAL-CONVENTION, 
    TimeInterval, 
    TimeStamp,
    DateAndTime, 
    TruthValue, 
    DisplayString, 
    MacAddress, 
    RowStatus
        FROM SNMPv2-TC
    mwStatistics
        FROM MERU-SMI
    MwlNetProtocol,
    MwlDeviceType,
    MwlOnOffSwitch,
    MwlQosProtocol,
    MwlQosCallState
        FROM MERU-TC;

  mwVoiceStatistics  MODULE-IDENTITY
    LAST-UPDATED "200506050000Z"
    ORGANIZATION "Meru Networks"
    CONTACT-INFO "support@merunetworks.com"
    DESCRIPTION
        "This MIB defines all the managed objects used to manage the Meru WLAN 
         Voice Statistics infrastructure"
    ::= { mwStatistics 3 } 
  
    
  
  mwPhoneTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF MwPhoneEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Phone Table "
    ::= { mwVoiceStatistics 1 }

  mwPhoneEntry  OBJECT-TYPE
    SYNTAX MwPhoneEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Phone Table "
    INDEX {  mwPhoneTableIndex  }
    ::= { mwPhoneTable 1 }

  MwPhoneEntry  ::=  SEQUENCE { 
       mwPhoneTableIndex                                           Integer32, 
       mwPhoneIp                                                   IpAddress,
       mwPhoneAp                                                   Integer32,
       mwPhoneMac                                                  MacAddress,
       mwPhoneType                                                 MwlQosProtocol,
       mwPhoneApName                                               DisplayString,
       mwPhoneServer                                               DisplayString,
       mwPhoneUsername                                             DisplayString,
       mwPhoneTransport                                            MwlNetProtocol,
       mwPhoneDeviceType                                           MwlDeviceType 
  }
   
   
  mwPhoneTableIndex  OBJECT-TYPE
    SYNTAX Integer32 
    MAX-ACCESS not-accessible 
    STATUS     current
    DESCRIPTION
         "The index value of the  table "
    ::= { mwPhoneEntry 1 }

  mwPhoneIp  OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes IP Address"
    ::= { mwPhoneEntry    2 }

  mwPhoneAp  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes AP ID"
    ::= { mwPhoneEntry    3 }

  mwPhoneMac  OBJECT-TYPE
    SYNTAX MacAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes MAC Address"
    ::= { mwPhoneEntry    4 }

  mwPhoneType  OBJECT-TYPE
    SYNTAX MwlQosProtocol
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Protocol Type"
    ::= { mwPhoneEntry    5 }

  mwPhoneApName  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes AP Name"
    ::= { mwPhoneEntry    6 }

  mwPhoneServer  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Server"
    ::= { mwPhoneEntry    7 }

  mwPhoneUsername  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Username"
    ::= { mwPhoneEntry    8 }

  mwPhoneTransport  OBJECT-TYPE
    SYNTAX MwlNetProtocol
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Transport"
    ::= { mwPhoneEntry    9 }

  mwPhoneDeviceType  OBJECT-TYPE
    SYNTAX MwlDeviceType
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Station Type"
    ::= { mwPhoneEntry   10 }

  mwPhoneCallTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF MwPhoneCallEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Phone Call Table "
    ::= { mwVoiceStatistics 2 }

  mwPhoneCallEntry  OBJECT-TYPE
    SYNTAX MwPhoneCallEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Phone Call Table "
    INDEX {  mwPhoneCallTableIndex  }
    ::= { mwPhoneCallTable 1 }

  MwPhoneCallEntry  ::=  SEQUENCE { 
       mwPhoneCallTableIndex                                       Integer32, 
       mwPhoneCallToIp                                             IpAddress,
       mwPhoneCallToAp                                             Integer32,
       mwPhoneCallType                                             MwlQosProtocol,
       mwPhoneCallToMac                                            MacAddress,
       mwPhoneCallState                                            MwlQosCallState,
       mwPhoneCallFromIp                                           IpAddress,
       mwPhoneCallFromAp                                           Integer32,
       mwPhoneCallFromMac                                          MacAddress,
       mwPhoneCallToApName                                         DisplayString,
       mwPhoneCallToFlowtag                                        Integer32,
       mwPhoneCallToPending                                        MwlOnOffSwitch,
       mwPhoneCallFromApName                                       DisplayString,
       mwPhoneCallToUsername                                       DisplayString,
       mwPhoneCallFromFlowtag                                      Integer32,
       mwPhoneCallFromPending                                      MwlOnOffSwitch,
       mwPhoneCallFromUsername                                     DisplayString 
  }
   
   
  mwPhoneCallTableIndex  OBJECT-TYPE
    SYNTAX Integer32 
    MAX-ACCESS not-accessible 
    STATUS     current
    DESCRIPTION
         "The index value of the  table "
    ::= { mwPhoneCallEntry 1 }

  mwPhoneCallToIp  OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To IP Address"
    ::= { mwPhoneCallEntry    2 }

  mwPhoneCallToAp  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To AP ID"
    ::= { mwPhoneCallEntry    3 }

  mwPhoneCallType  OBJECT-TYPE
    SYNTAX MwlQosProtocol
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Protocol Type"
    ::= { mwPhoneCallEntry    4 }

  mwPhoneCallToMac  OBJECT-TYPE
    SYNTAX MacAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To MAC Address"
    ::= { mwPhoneCallEntry    5 }

  mwPhoneCallState  OBJECT-TYPE
    SYNTAX MwlQosCallState
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Call state"
    ::= { mwPhoneCallEntry    6 }

  mwPhoneCallFromIp  OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From IP Address"
    ::= { mwPhoneCallEntry    7 }

  mwPhoneCallFromAp  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From AP ID"
    ::= { mwPhoneCallEntry    8 }

  mwPhoneCallFromMac  OBJECT-TYPE
    SYNTAX MacAddress
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From MAC Address"
    ::= { mwPhoneCallEntry    9 }

  mwPhoneCallToApName  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To AP Name"
    ::= { mwPhoneCallEntry   10 }

  mwPhoneCallToFlowtag  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To Flow Tag"
    ::= { mwPhoneCallEntry   11 }

  mwPhoneCallToPending  OBJECT-TYPE
    SYNTAX MwlOnOffSwitch
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To Qos Pending"
    ::= { mwPhoneCallEntry   12 }

  mwPhoneCallFromApName  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From AP Name"
    ::= { mwPhoneCallEntry   13 }

  mwPhoneCallToUsername  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes To Username"
    ::= { mwPhoneCallEntry   14 }

  mwPhoneCallFromFlowtag  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From Flow Tag"
    ::= { mwPhoneCallEntry   15 }

  mwPhoneCallFromPending  OBJECT-TYPE
    SYNTAX MwlOnOffSwitch
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From Qos Pending"
    ::= { mwPhoneCallEntry   16 }

  mwPhoneCallFromUsername  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes From Username"
    ::= { mwPhoneCallEntry   17 }

  mwVoiceStatusTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF MwVoiceStatusEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Voice Status Table "
    ::= { mwVoiceStatistics 3 }

  mwVoiceStatusEntry  OBJECT-TYPE
    SYNTAX MwVoiceStatusEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This object describes Voice Status Table "
    INDEX {  mwVoiceStatusTableIndex  }
    ::= { mwVoiceStatusTable 1 }

  MwVoiceStatusEntry  ::=  SEQUENCE { 
       mwVoiceStatusTableIndex                                     Integer32, 
       mwVoiceStatusAp                                             Integer32,
       mwVoiceStatusApName                                         DisplayString,
       mwVoiceStatusPhoneCount                                     Unsigned32,
       mwVoiceStatusRejectCount                                    Counter64,
       mwVoiceStatusActiveCallCount                                Unsigned32,
       mwVoiceStatusPendingCallCount                               Unsigned32 
  }
   
   
  mwVoiceStatusTableIndex  OBJECT-TYPE
    SYNTAX Integer32 
    MAX-ACCESS not-accessible 
    STATUS     current
    DESCRIPTION
         "The index value of the  table "
    ::= { mwVoiceStatusEntry 1 }

  mwVoiceStatusAp  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes AP ID"
    ::= { mwVoiceStatusEntry    2 }

  mwVoiceStatusApName  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes AP Name"
    ::= { mwVoiceStatusEntry    3 }

  mwVoiceStatusPhoneCount  OBJECT-TYPE
    SYNTAX Unsigned32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Phone Count"
    ::= { mwVoiceStatusEntry    4 }

  mwVoiceStatusRejectCount  OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Call Rejected Count"
    ::= { mwVoiceStatusEntry    5 }

  mwVoiceStatusActiveCallCount  OBJECT-TYPE
    SYNTAX Unsigned32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Active Call Count"
    ::= { mwVoiceStatusEntry    6 }

  mwVoiceStatusPendingCallCount  OBJECT-TYPE
    SYNTAX Unsigned32
    MAX-ACCESS  read-only 
    STATUS     current
    DESCRIPTION
         "This object describes Qos Pending Call Count"
    ::= { mwVoiceStatusEntry    7 }

  
END