librenms/librenms

View on GitHub
mibs/hp/HP-ICF-TRANSCEIVER-MIB

Summary

Maintainability
Test Coverage
HP-ICF-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32, TimeTicks 
            FROM SNMPv2-SMI
        SnmpAdminString
            FROM SNMP-FRAMEWORK-MIB
        MODULE-COMPLIANCE, OBJECT-GROUP
            FROM SNMPv2-CONF
        TruthValue
            FROM SNMPv2-TC
        hpSwitch
            FROM HP-ICF-OID
        ifIndex
            FROM IF-MIB;

    hpicfTransceiverMIB MODULE-IDENTITY
         LAST-UPDATED "201107250000Z" -- July 25, 2011
         ORGANIZATION "HP Networking"
         CONTACT-INFO "Hewlett Packard Company
                       8000 Foothills Blvd.
                       Roseville, CA 95747"
         DESCRIPTION  "This MIB module describes HP transceiver
                       information."
         REVISION     "201107250000Z" -- July 25, 2011
         DESCRIPTION  "Deprecated hpicfXcvrDiagnosticsTimeStamp, add
                       hpicfXcvrDiagnosticsTimeTicks."
         REVISION     "201106080000Z" -- June 8, 2011
         DESCRIPTION  "Add objects for reporting phy and cable 
                       diagnostics information."
         REVISION     "201103140000Z" -- March 14, 2011
         DESCRIPTION  "Change hpicfXcvrInfoEntry INDEX to ifIndex and
                      hpicfXcvrPortIndex to Integer32 and read-only."
         REVISION     "201103020000Z" -- March 2, 2011
         DESCRIPTION  "Management Infromation Base module for transceiver
                       information and statistics."

         ::= { hpSwitch 82 }

-- *******************************************************************
-- Textual Conventions
-- *******************************************************************

-- *******************************************************************
-- Transceiver Objects
-- *******************************************************************

    hpicfXcvrObjects               OBJECT IDENTIFIER
          ::= { hpicfTransceiverMIB 1 }

    hpicfXcvrInfo                  OBJECT IDENTIFIER 
          ::= { hpicfXcvrObjects 1 }

-- *******************************************************************
-- Transceiver Info
-- *******************************************************************

    hpicfXcvrInfoTable OBJECT-TYPE
          SYNTAX      SEQUENCE OF HpicfXcvrInfoEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                 "A table of objects that display transceiver
                  characteristics." 
          ::= { hpicfXcvrInfo 1 }

    hpicfXcvrInfoEntry OBJECT-TYPE
          SYNTAX      HpicfXcvrInfoEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                 "A set of objects that displays information of
                  a transceiver."
          INDEX { ifIndex }
          ::= { hpicfXcvrInfoTable 1 }

    HpicfXcvrInfoEntry ::=
          SEQUENCE {
             hpicfXcvrPortIndex      Integer32,
             hpicfXcvrPortDesc       SnmpAdminString,
             hpicfXcvrModel          SnmpAdminString,
             hpicfXcvrSerial         SnmpAdminString,
             hpicfXcvrType           SnmpAdminString,
             hpicfXcvrConnectorType  SnmpAdminString,
             hpicfXcvrWavelength     SnmpAdminString,
             hpicfXcvrTxDist         SnmpAdminString,
             hpicfXcvrDiagnostics    INTEGER,
             hpicfXcvrDiagnosticsUpdate TruthValue,
             hpicfXcvrTemp           Integer32,
             hpicfXcvrVoltage        Unsigned32,
             hpicfXcvrBias           Unsigned32,
             hpicfXcvrTxPower        Integer32,
             hpicfXcvrRxPower        Integer32,
             hpicfXcvrAlarms         BITS,
             hpicfXcvrErrors         BITS,
             hpicfXcvrTempHiAlarm    Integer32,
             hpicfXcvrTempLoAlarm    Integer32,
             hpicfXcvrTempHiWarn     Integer32,
             hpicfXcvrTempLoWarn     Integer32,
             hpicfXcvrVccHiAlarm     Unsigned32, 
             hpicfXcvrVccLoAlarm     Unsigned32, 
             hpicfXcvrVccHiWarn      Unsigned32, 
             hpicfXcvrVccLoWarn      Unsigned32, 
             hpicfXcvrBiasHiAlarm    Unsigned32,
             hpicfXcvrBiasLoAlarm    Unsigned32,
             hpicfXcvrBiasHiWarn     Unsigned32,
             hpicfXcvrBiasLoWarn     Unsigned32,
             hpicfXcvrPwrOutHiAlarm  Unsigned32,
             hpicfXcvrPwrOutLoAlarm  Unsigned32,
             hpicfXcvrPwrOutHiWarn   Unsigned32,
             hpicfXcvrPwrOutLoWarn   Unsigned32,
             hpicfXcvrRcvPwrHiAlarm  Unsigned32,
             hpicfXcvrRcvPwrLoAlarm  Unsigned32,
             hpicfXcvrRcvPwrHiWarn   Unsigned32,
             hpicfXcvrRcvPwrLoWarn   Unsigned32,
             hpicfXcvrDiagnosticsTimeStamp SnmpAdminString,
             hpicfXcvrPhyLinkStatus  INTEGER,
             hpicfXcvrPhySpeed       Unsigned32,
             hpicfXcvrPhyDuplex      INTEGER,
             hpicfXcvrMdiPairACableStatus INTEGER,
             hpicfXcvrMdiPairACableLength Unsigned32,
             hpicfXcvrMdiPairADistanceToFault Unsigned32,
             hpicfXcvrMdiPairAPolaritySwap INTEGER,
             hpicfXcvrMdiPairASkew Unsigned32,
             hpicfXcvrMdiPairBCableStatus INTEGER,
             hpicfXcvrMdiPairBCableLength Unsigned32,
             hpicfXcvrMdiPairBDistanceToFault Unsigned32,
             hpicfXcvrMdiPairBPolaritySwap INTEGER,
             hpicfXcvrMdiPairBSkew Unsigned32,
             hpicfXcvrMdiPairCCableStatus INTEGER,
             hpicfXcvrMdiPairCCableLength Unsigned32,
             hpicfXcvrMdiPairCDistanceToFault Unsigned32,
             hpicfXcvrMdiPairCPolaritySwap INTEGER,
             hpicfXcvrMdiPairCSkew Unsigned32,
             hpicfXcvrMdiPairDCableStatus INTEGER,
             hpicfXcvrMdiPairDCableLength Unsigned32,
             hpicfXcvrMdiPairDDistanceToFault Unsigned32,
             hpicfXcvrMdiPairDPolaritySwap INTEGER,
             hpicfXcvrMdiPairDSkew Unsigned32,
             hpicfXcvrMdiPairABSwap INTEGER,
             hpicfXcvrMdiPairCDSwap INTEGER,
             hpicfXcvrDiagnosticsTimeTicks TimeTicks
          }

    hpicfXcvrPortIndex OBJECT-TYPE
          SYNTAX      Integer32(1..2147483647)
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "The interface number for this entry."
          ::= { hpicfXcvrInfoEntry 1 }

    hpicfXcvrPortDesc OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..8))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the interface."
          ::= { hpicfXcvrInfoEntry 2 }

    hpicfXcvrModel OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..32))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the transceiver
                  model number."
          ::= { hpicfXcvrInfoEntry 3 }

    hpicfXcvrSerial OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..32))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the transceiver
                  serial number."
          ::= { hpicfXcvrInfoEntry 4 }

    hpicfXcvrType OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..32))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the transceiver type."
          ::= { hpicfXcvrInfoEntry 5 }

    hpicfXcvrConnectorType OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..64))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the transceiver
                  connector type."
          ::= { hpicfXcvrInfoEntry 6 }

    hpicfXcvrWavelength OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..96))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the central optical
                  wavelength.

                  n/a will be reported for copper transceivers." 
          ::= { hpicfXcvrInfoEntry 7 }

    hpicfXcvrTxDist OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..64))
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "A textual description of the link length
                  supported by the transceiver."
          ::= { hpicfXcvrInfoEntry 8 }

    hpicfXcvrDiagnostics OBJECT-TYPE
          SYNTAX      INTEGER {
                              none(0),
                              dom(1),
                              vct(2),
                              other(3)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates transceiver diagnostic support.
                  May be one of Virtual Cable Test (VCT), Diagnostic 
                  Optical Monitoring (DOM), other or none."
          ::= { hpicfXcvrInfoEntry 9 }

    hpicfXcvrDiagnosticsUpdate OBJECT-TYPE
          SYNTAX      TruthValue
          MAX-ACCESS  read-write
          STATUS      current
          DESCRIPTION
                 "This object will cause specific actions
                  depending on the diagnostic support of the
                  transceiver.

                  Transceiver Diagnostic support:

                  None  : No action taken.
                  DOM   : Will update diagnostic information
                          for the transceiver.
                  VCT   : Will update diagnostic information
                          for the transceiver.
                  Other : Vendor specific.

                  The value of the object will be reset after
                  the completion of the update.

                  Please note: VCT and other (cable-diagnostics)
                  may cause a loss of link and take a few second
                  to run for each interface."
          ::= { hpicfXcvrInfoEntry 10 }

    hpicfXcvrTemp OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of degrees Celsius"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This is transceiver internal temperature
                  in thousandths of degrees Celsius.

                  As an example: 49120 is 49.120 degrees Celsius.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 11 }

    hpicfXcvrVoltage OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "hundreds of microvolts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This is transceiver supply voltage
                  in hundreds of microvolts.

                  As an example: 32928 is 3.2928 volts.

                  Will be zero if the transceiver does not report
                  this object.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 12 }

    hpicfXcvrBias OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "microamps"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This is Tx bias current in microamps.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 13 }

    hpicfXcvrTxPower OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of dBm"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This is transmit output power
                  in thousandths of dBm.

                  As an example: -5840 is -5.840dBm.

                  -in dBm (0 microwatts) will be reported as -99999999.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 14 }

    hpicfXcvrRxPower OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of dBm"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This is received optical power
                  in thousandths of dBm.

                  As an example: -5840 is -5.840dBm.

                  -in dBm (0 microwatts) will be reported as -99999999.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 15 }

    hpicfXcvrAlarms OBJECT-TYPE
          SYNTAX      BITS {
                           rxPowerLowWarning(0),
                           rxPowerHighWarning(1),
                           txPowerLowWarning(2),
                           txPowerHighWarning(3),
                           txBiasLowWarning(4),
                           txBiasHighWarning(5),
                           vccLowWarning(6),
                           vccHighWarning(7),
                           tempLowWarning(8),
                           tempHighWarning(9),
                           rxPowerLowAlarm(10),
                           rxPowerHighAlarm(11),
                           txPowerLowAlarm(12),
                           txPowerHighAlarm(13),
                           txBiasLowAlarm(14),
                           txBiasHighAlarm(15),
                           vccLowAlarm(16),
                           vccHighAlarm(17),
                           tempLowAlarm(18),
                           tempHighAlarm(19)
                           }
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
                 "Bitmask indicating transceiver alarms,
                  Rx power low warning(0)
                  Rx power high warning(1)
                  Tx power low warning(2)
                  Tx power high warning(3)
                  Tx bias low warning(4)
                  Tx bias high warning(5)
                  Vcc low warning(6)
                  Vcc high warning(7)
                  Temp low warning(8)
                  Temp high warning(9)
                  Rx power low alarm(10)
                  Rx power high alarm(11)
                  Tx power low alarm(12)
                  Tx power high alarm(13)
                  Tx bias low alarm(14)
                  Tx bias high alarm(15)
                  Vcc low alarm(16)
                  Vcc high alarm(17)
                  Temp low alarm(18)
                  Temp high alarm(19) 

                  Unused(20-31)

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 16 }

    hpicfXcvrErrors OBJECT-TYPE
          SYNTAX      BITS {
                           xcvrIOError(0),
                           xcvrChecksum(1),
                           xcvrTypeAndPortConfigMismatch(2),
                           xcvrTypeNotSupported(3),
                           wisLocalFault(4),
                           rcvOpticalPowerFault(5),
                           pmapmdReceiverLocalFault(6),
                           pcsReceiveLocalFault(7),
                           phyXSReceiveLocalFault(8),
                           laserBiasCurrentFault(9),
                           laserTemperatureFault(10),
                           laserOutputPowerFault(11),
                           txFault(12),
                           pmapmdTransmitterLocalFault(13),
                           pcsTransmitLocalFault(14),
                           phyXSTransmitLocalFault(15),
                           rxLossOfSignal(16)
                           }
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
                 "Bitmask indicating transceiver errors.
                  Transceiver information I/O error(0)
                  Transceiver information checksum error(1)
                  Transceiver type and port configuration mismatch(2)
                  Transceiver type not supported by port hardware(3)
                  WIS local fault(4)
                  Receive optical power fault(5)
                  PMA/PMD receiver local fault(6)
                  PCS receive local fault(7)
                  PHY XS receive local fault(8)
                  Laser bias current fault(9)
                  Laser temperature fault(10)
                  Laser output power fault(11)
                  TX fault(12)
                  PMA/PMD transmitter local fault(13)
                  PCS transmit local fault(14)
                  PHY XS Transmit Local Fault(15)
                  RX loss of signal(16)

                  Unused(17-31)

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 17 }

    hpicfXcvrTempHiAlarm OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of degrees Celsius"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver temperature high alarm
                  threshold limit in thousandths of degrees Celsius.

                  As an example: 49120 is 49.120 degrees Celsius.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 18 }

    hpicfXcvrTempLoAlarm OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of degrees Celsius"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver temperature low alarm
                  threshold limit in thousandths of degrees Celsius.

                  As an example: 49120 is 49.120 degrees Celsius.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 19 }

    hpicfXcvrTempHiWarn OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of degrees Celsius"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver temperature high warning
                  threshold limit in thousandths of degrees Celsius.

                  As an example: 49120 is 49.120 degrees Celsius.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 20 }

    hpicfXcvrTempLoWarn OBJECT-TYPE
          SYNTAX      Integer32
          UNITS       "thousandths of degrees Celsius"
          MAX-ACCESS  read-only
          STATUS        current
          DESCRIPTION
                 "Transceiver temperature low warning
                  threshold limit in thousandths of degrees Celsius.

                  As an example: 49120 is 49.120 degrees Celsius.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 21 }

    hpicfXcvrVccHiAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "hundreds of microvolts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver VCC high alarm
                  threshold limit in hundreds of microvolts.

                  As an example: 32928 is 3.2928 volts.

                  Returns zero if not supported on the transceiver.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 22 }

    hpicfXcvrVccLoAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "hundreds of microvolts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver VCC low alarm
                  threshold limit in hundreds of microvolts.

                  As an example: 32928 is 3.2928 volts.

                  Returns zero if not supported on the transceiver.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 23 }

    hpicfXcvrVccHiWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "hundreds of microvolts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver VCC high warning
                  threshold limit in hundreds of microvolts.

                  As an example: 32928 is 3.2928 volts.

                  Returns zero if not supported on the transceiver.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 24 }

    hpicfXcvrVccLoWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "hundreds of microvolts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver VCC low warning
                  threshold limit in hundreds of microvolts.

                  As an example: 32928 is 3.2928 volts.

                  Returns zero if not supported on the transceiver.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 25 }

    hpicfXcvrBiasHiAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "microamps"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver bias high alarm
                  threshold limit in microamps.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 26 }

    hpicfXcvrBiasLoAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "microamps"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver bias low alarm
                  threshold limit in microamps.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 27 }

    hpicfXcvrBiasHiWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "microamps"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver bias high warning
                  threshold limit in microamps.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 28 }

    hpicfXcvrBiasLoWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "microamps"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver bias low warning
                  threshold limit in microamps.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 29 }

    hpicfXcvrPwrOutHiAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver transmit power high alarm
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 30 }

    hpicfXcvrPwrOutLoAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver transmit power low alarm
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 31 }

    hpicfXcvrPwrOutHiWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver transmit power high warning
                  threshold limit in tenths of microwatts

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 32 }

    hpicfXcvrPwrOutLoWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver transmit power low warning
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 33 }

    hpicfXcvrRcvPwrHiAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver receive power high alarm
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 34 }

    hpicfXcvrRcvPwrLoAlarm OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver receive power low alarm
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 35 }

    hpicfXcvrRcvPwrHiWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver receive power high warning
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 36 }

    hpicfXcvrRcvPwrLoWarn OBJECT-TYPE
          SYNTAX      Unsigned32 (0..65535)
          UNITS       "tenths of microwatts"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "Transceiver receive power low warning
                  threshold limit in tenths of microwatts.

                  As an example: 10000 is 1 milliwatt.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is DOM."
          ::= { hpicfXcvrInfoEntry 37 }

    hpicfXcvrDiagnosticsTimeStamp OBJECT-TYPE
          SYNTAX      SnmpAdminString (SIZE(1..64))
          MAX-ACCESS  read-only
          STATUS      deprecated
          DESCRIPTION
                 "********* THIS OBJECT IS DEPRECATED *********

                  A textual description of the diagnostics
                  information updated for the last time in the
                  transceiver.

                  This object has been deprecated. Its functionality
                  has been replaced by hpicfXcvrDiagnosticsTimeticks."
          ::= { hpicfXcvrInfoEntry 38 }

    hpicfXcvrPhyLinkStatus  OBJECT-TYPE
          SYNTAX      INTEGER {
                              down(0),
                              up(1)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the link status as reported
                  by the physical entity.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 39 }

    hpicfXcvrPhySpeed  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "megabits per second"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the speed in Mbps as reported
                  by the physical entity. 

                  Will be zero if speed and duplex are unresolved.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 40 }

    hpicfXcvrPhyDuplex  OBJECT-TYPE
          SYNTAX      INTEGER {
                              half(0),
                              full(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the duplex as reported by
                  the physical entity.

                  Will be unspecified if speed and duplex are unresolved.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 41 }

    hpicfXcvrMdiPairACableStatus  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              short(1),
                              open(2),
                              failed(3),
                              impedanceMismatch(4),
                              unspecified(5)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the diagnostics
                  test status on the cable pair.

                  Normal = No cable fault detected.
                  Open = Lack of continuity between ends.
                  Short = Short detected.
                  Impedance mismatch =
                         - Cable pair is not connected properly or
                         - Cable pair is damaged or
                         - Connector is faulty.
                  Failed = TDR test failed on cable pair.
                  Unspecified : This object is unavailable or not reported.
 
                  As reported through cable diagnostics.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 42 }

    hpicfXcvrMdiPairACableLength  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable pair length in
                  meters as reported by cable diagnostics.

                  A gigabit link must be present for this object
                  to be non zero.
 
                  Will be zero if not available or the transceiver
                  does not report this object.

                  Accuracy is +/- 10 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 43 }

    hpicfXcvrMdiPairADistanceToFault  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the distance in meters to
                  a fault in the cable pair as reported through cable
                  diagnostics.

                  Will be zero if no fault or the transceiver does not
                  report this object. 

                  Accuracy is +/- 2 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 44 }

    hpicfXcvrMdiPairAPolaritySwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              reversed(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates if the cable pair connected
                  to the phy is inverted as reported through cable
                  diagnostics.

                  Will be unspecified if the this object is unavailable
                  or not reported.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 45 }

    hpicfXcvrMdiPairASkew    OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "nanoseconds"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the delay skew in nanoseconds 
                  of this cable pair and the fastest cable pair as
                  reported through cable diagnostics.

                  Will be zero if the lowest of the pairs or if the
                  transceiver does not report this object.  

                  Accuracy is +/- 8 ns.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 46 }

    hpicfXcvrMdiPairBCableStatus  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              short(1),
                              open(2),
                              failed(3),
                              impedanceMismatch(4),
                              unspecified(5) 
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable diagnostics
                  test status on the cable pair.

                  Normal = No cable fault detected.
                  Open = Lack of continuity between ends.
                  Short = Short detected.
                  Impedance mismatch =
                         - Cable pair is not connected properly or
                         - Cable pair is damaged or
                         - Connector is faulty.
                  Failed = TDR test failed on cable pair.
                  Unspecified : This object is unavailable or not 
                                reported. 
 
                  As reported through cable diagnostics.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 47 }

    hpicfXcvrMdiPairBCableLength  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                  "This object indicates the cable pair length in 
                  meters as reported by cable diagnostics.

                  A gigabit link must be present for this object
                  to be non zero.
 
                  Will be zero if not available or the transceiver
                  does not report this object. 

                  Accuracy is +/- 10 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 48 }

    hpicfXcvrMdiPairBDistanceToFault  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the distance in meters to
                  a fault in the cable pair as reported through cable
                  diagnostics.

                  Will be zero if no fault or the transceiver does not
                  report this object. 

                  Accuracy is +/- 2 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 49 }

    hpicfXcvrMdiPairBPolaritySwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              reversed(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates if the cable pair connected
                  to the phy were inverted as reported through cable
                  diagnostics.

                  Will be unspecified if the this object is unavailable
                  or not reported.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 50 }

    hpicfXcvrMdiPairBSkew    OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "nanoseconds"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the delay skew in nanoseconds 
                  of this cable pair and the fastest cable pair as
                  reported through cable diagnostics.

                  Will be zero if the lowest of the pairs or if the
                  transceiver does not report this object.   

                  Accuracy is +/- 8 ns.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 51 }

    hpicfXcvrMdiPairCCableStatus  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              short(1),
                              open(2),
                              failed(3),
                              impedanceMismatch(4),
                              unspecified(5) 
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable diagnostics
                  test status on the cable pair.

                  Normal = No cable fault detected.
                  Open = Lack of continuity between ends.
                  Short = Short detected.
                  Impedance Mismatch =
                         - Cable pair is not connected properly or
                         - Cable pair is damaged or
                         - Connector is faulty.
                  Failed = TDR test failed on cable pair.
                  Unspecified : This object is unavailable or not reported. 
 
                  As reported through cable diagnostics.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 52 }

    hpicfXcvrMdiPairCCableLength  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable length in meters 
                  of the cable pair as reported through cable
                  diagnostics.

                  A gigabit link must be present for this object
                  to be non zero.
 
                  Will be zero if not available or the transceiver
                  does not report this object.  

                  Accuracy is +/- 10 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 53 }

    hpicfXcvrMdiPairCDistanceToFault  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the distance in meters to
                  a fault in the cable pair as reported through cable
                  diagnostics. 

                  Will be zero if there is no fault or the
                  transceiver does not report this object. 
                 
                  Accuracy is +/- 2 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 54 }

    hpicfXcvrMdiPairCPolaritySwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              reversed(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates if the cable pair connected
                  to the phy were inverted as reported through cable
                  diagnostics.

                  Will be unspecified if the this object is unavailable
                  or not reported.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 55 }

    hpicfXcvrMdiPairCSkew    OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "nanoseconds"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the delay skew in nanoseconds 
                  of this cable pair and the fastest cable pair as
                  reported through cable diagnostics.

                  Will be zero if the lowest of the pairs or if the
                  transceiver does not report this object.   

                  Accuracy is +/- 8 ns.
            
                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 56 }

    hpicfXcvrMdiPairDCableStatus  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              short(1),
                              open(2),
                              failed(3),
                              impedanceMismatch(4),
                              unspecified(5) 
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable diagnostics
                  test status on the cable pair.

                  Normal = No cable fault detected.
                  Open = Lack of continuity between ends.
                  Short = Short detected.
                  Impedance Mismatch =
                         - Cable pair is not connected properly or
                         - Cable pair is damaged or
                         - Connector is faulty.
                  Failed = TDR test failed on cable pair.
                  Unspecified : This object is unavailable or not 
                                reported. 
 
                  As reported through cable diagnostics.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 57 }

    hpicfXcvrMdiPairDCableLength  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the cable length in meters 
                  of the cable pair as reported through cable
                  diagnostics.

                  A gigabit link must be present for this object
                  to be non zero.
 
                  Will be zero if not available or the transceiver
                  does not report this object.  

                  Accuracy is +/- 10 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 58 }

    hpicfXcvrMdiPairDDistanceToFault  OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "meters"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the distance in meters to
                  a fault in the cable pair as reported through cable
                  diagnostics.

                  Will be zero if no fault or the transceiver does not
                  report this object. 

                  Accuracy is +/- 2 meters.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 59 }

    hpicfXcvrMdiPairDPolaritySwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              normal(0),
                              reversed(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates if the cable pair connected
                  to the phy were inverted as reported through cable
                  diagnostics.

                  Will be unspecified if the this object is unavailable
                  or not reported.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 60 }

    hpicfXcvrMdiPairDSkew    OBJECT-TYPE
          SYNTAX      Unsigned32(0..4294967295)
          UNITS       "nanoseconds"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the delay skew in nanoseconds 
                  of this cable pair and the fastest cable pair as
                  reported through cable diagnostics.

                  Will be zero if the lowest of the pairs or if the
                  transceiver does not report this object.   

                  Accuracy is +/- 8 ns.

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 61 }

    hpicfXcvrMdiPairABSwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              mdi(0),
                              mdix(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates the if the channels are
                  swapped for channels A and B as reported through
                  cable diagnostics.

                  MDI  : Channel A received on MDI[1], Channel B on MDI[0]
                  MDIX : Channel A received on MDI[0], Channel B on MDI[1]
                  Unspecified : This object is unavailable or not reported. 

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 62 }

    hpicfXcvrMdiPairCDSwap  OBJECT-TYPE
          SYNTAX      INTEGER {
                              mdi(0),
                              mdix(1),
                              unspecified(2)
                              }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "This object indicates if the channels are
                  swapped for channels C and D as reported through
                  cable diagnostics.

                  MDI  : Channel C received on MDI[3], Channel D on MDI[2]
                  MDIX : Channel C received on MDI[2], Channel D on MDI[3].
                  Unspecified : This object is unavailable or not reported. 

                  The value of this object is valid when the value of 
                  the hpicfXcvrDiagnostics object is VCT or other."
          ::= { hpicfXcvrInfoEntry 63 }

    hpicfXcvrDiagnosticsTimeTicks OBJECT-TYPE
          SYNTAX      TimeTicks
          UNITS       "centi-seconds"
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION
                 "The value of sysUpTime of when this diagnostic
                  information was last updated. If this diagnostic
                  information was never updated, then this object
                  will contain a zero value."
          ::= { hpicfXcvrInfoEntry 64 }

-- *******************************************************************
-- Conformance Section
-- *******************************************************************

    hpicfXcvrConformance  OBJECT IDENTIFIER
          ::= { hpicfTransceiverMIB 2 }

    hpicfXcvrGroups       OBJECT IDENTIFIER
          ::= { hpicfXcvrConformance 1 }

    hpicfXcvrInfoGroup OBJECT-GROUP
          OBJECTS {
             hpicfXcvrPortIndex,
             hpicfXcvrPortDesc,
             hpicfXcvrModel,
             hpicfXcvrSerial,
             hpicfXcvrType,
             hpicfXcvrConnectorType,
             hpicfXcvrWavelength,
             hpicfXcvrTxDist,
             hpicfXcvrDiagnostics,
             hpicfXcvrDiagnosticsUpdate,
             hpicfXcvrTemp,
             hpicfXcvrVoltage,
             hpicfXcvrBias,
             hpicfXcvrRxPower,
             hpicfXcvrTxPower,
             hpicfXcvrAlarms,
             hpicfXcvrErrors,
             hpicfXcvrTempHiAlarm,
             hpicfXcvrTempLoAlarm,
             hpicfXcvrTempHiWarn,
             hpicfXcvrTempLoWarn,
             hpicfXcvrVccHiAlarm, 
             hpicfXcvrVccLoAlarm, 
             hpicfXcvrVccHiWarn, 
             hpicfXcvrVccLoWarn, 
             hpicfXcvrBiasHiAlarm,
             hpicfXcvrBiasLoAlarm,
             hpicfXcvrBiasHiWarn,
             hpicfXcvrBiasLoWarn,
             hpicfXcvrPwrOutHiAlarm,
             hpicfXcvrPwrOutLoAlarm,
             hpicfXcvrPwrOutHiWarn,
             hpicfXcvrPwrOutLoWarn,
             hpicfXcvrRcvPwrHiAlarm,
             hpicfXcvrRcvPwrLoAlarm,
             hpicfXcvrRcvPwrHiWarn,
             hpicfXcvrRcvPwrLoWarn,
             hpicfXcvrDiagnosticsTimeStamp,
             hpicfXcvrPhyLinkStatus,
             hpicfXcvrPhySpeed,
             hpicfXcvrPhyDuplex,
             hpicfXcvrMdiPairACableStatus,
             hpicfXcvrMdiPairACableLength,
             hpicfXcvrMdiPairADistanceToFault,
             hpicfXcvrMdiPairAPolaritySwap,
             hpicfXcvrMdiPairASkew,
             hpicfXcvrMdiPairBCableStatus,
             hpicfXcvrMdiPairBCableLength,
             hpicfXcvrMdiPairBDistanceToFault,
             hpicfXcvrMdiPairBPolaritySwap,
             hpicfXcvrMdiPairBSkew,
             hpicfXcvrMdiPairCCableStatus,
             hpicfXcvrMdiPairCCableLength,
             hpicfXcvrMdiPairCDistanceToFault,
             hpicfXcvrMdiPairCPolaritySwap,
             hpicfXcvrMdiPairCSkew,
             hpicfXcvrMdiPairDCableStatus,
             hpicfXcvrMdiPairDCableLength,
             hpicfXcvrMdiPairDDistanceToFault,
             hpicfXcvrMdiPairDPolaritySwap,
             hpicfXcvrMdiPairDSkew,
             hpicfXcvrMdiPairABSwap,
             hpicfXcvrMdiPairCDSwap
          }
    STATUS  deprecated
    DESCRIPTION
           "********* THIS GROUP IS DEPRECATED *********

            A collection of objects representing transceiver 
            information.

            This object has been deprecated and replaced with
            hpicfXcvrInfoGroup1."
          ::= { hpicfXcvrGroups 1 }

    hpicfXcvrInfoGroup1 OBJECT-GROUP
          OBJECTS {
             hpicfXcvrPortIndex,
             hpicfXcvrPortDesc,
             hpicfXcvrModel,
             hpicfXcvrSerial,
             hpicfXcvrType,
             hpicfXcvrConnectorType,
             hpicfXcvrWavelength,
             hpicfXcvrTxDist,
             hpicfXcvrDiagnostics,
             hpicfXcvrDiagnosticsUpdate,
             hpicfXcvrTemp,
             hpicfXcvrVoltage,
             hpicfXcvrBias,
             hpicfXcvrRxPower,
             hpicfXcvrTxPower,
             hpicfXcvrAlarms,
             hpicfXcvrErrors,
             hpicfXcvrTempHiAlarm,
             hpicfXcvrTempLoAlarm,
             hpicfXcvrTempHiWarn,
             hpicfXcvrTempLoWarn,
             hpicfXcvrVccHiAlarm, 
             hpicfXcvrVccLoAlarm, 
             hpicfXcvrVccHiWarn, 
             hpicfXcvrVccLoWarn, 
             hpicfXcvrBiasHiAlarm,
             hpicfXcvrBiasLoAlarm,
             hpicfXcvrBiasHiWarn,
             hpicfXcvrBiasLoWarn,
             hpicfXcvrPwrOutHiAlarm,
             hpicfXcvrPwrOutLoAlarm,
             hpicfXcvrPwrOutHiWarn,
             hpicfXcvrPwrOutLoWarn,
             hpicfXcvrRcvPwrHiAlarm,
             hpicfXcvrRcvPwrLoAlarm,
             hpicfXcvrRcvPwrHiWarn,
             hpicfXcvrRcvPwrLoWarn,
             hpicfXcvrPhyLinkStatus,
             hpicfXcvrPhySpeed,
             hpicfXcvrPhyDuplex,
             hpicfXcvrMdiPairACableStatus,
             hpicfXcvrMdiPairACableLength,
             hpicfXcvrMdiPairADistanceToFault,
             hpicfXcvrMdiPairAPolaritySwap,
             hpicfXcvrMdiPairASkew,
             hpicfXcvrMdiPairBCableStatus,
             hpicfXcvrMdiPairBCableLength,
             hpicfXcvrMdiPairBDistanceToFault,
             hpicfXcvrMdiPairBPolaritySwap,
             hpicfXcvrMdiPairBSkew,
             hpicfXcvrMdiPairCCableStatus,
             hpicfXcvrMdiPairCCableLength,
             hpicfXcvrMdiPairCDistanceToFault,
             hpicfXcvrMdiPairCPolaritySwap,
             hpicfXcvrMdiPairCSkew,
             hpicfXcvrMdiPairDCableStatus,
             hpicfXcvrMdiPairDCableLength,  
             hpicfXcvrMdiPairDDistanceToFault,  
             hpicfXcvrMdiPairDPolaritySwap, 
             hpicfXcvrMdiPairDSkew,    
             hpicfXcvrMdiPairABSwap,  
             hpicfXcvrMdiPairCDSwap,
             hpicfXcvrDiagnosticsTimeTicks
          }
    STATUS  current
    DESCRIPTION
           "A collection of objects representing transceiver 
            information."
          ::= { hpicfXcvrGroups 2 }

    hpicfXcvrCompliances OBJECT IDENTIFIER ::=
        { hpicfXcvrConformance 2 }

    hpicfXcvrCompliance  MODULE-COMPLIANCE
          STATUS  deprecated
          DESCRIPTION
                "********* THIS COMPLIANCE IS DEPRECATED *********

                Describes the requirements for conformance to the
                transceiver MIB.

                This compliance section has been deprecated and
                replaced with hpicfXcvrCompliance1."
    MODULE  -- this module
          MANDATORY-GROUPS { hpicfXcvrInfoGroup }
          ::= { hpicfXcvrCompliances 1 }

    hpicfXcvrCompliance1  MODULE-COMPLIANCE
          STATUS  current
          DESCRIPTION
                "Describes the requirements for conformance to the
                transceiver MIB."
    MODULE  -- this module
          MANDATORY-GROUPS { hpicfXcvrInfoGroup1 }
          ::= { hpicfXcvrCompliances 2 }
END