librenms/librenms

View on GitHub
mibs/huawei/HUAWEI-ALARM-MIB

Summary

Maintainability
Test Coverage
-- ==================================================================
-- Copyright (C) 2019 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- 
-- Description: HUAWEI ALARM MIB
-- Reference:
-- Version: V2.17
-- History: 
--  V1.0      2009-03-20   publish
-- ==================================================================

    HUAWEI-ALARM-MIB DEFINITIONS ::= BEGIN
 
        IMPORTS
            hwDatacomm            
                FROM HUAWEI-MIB            
            OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP            
                FROM SNMPv2-CONF            
            Integer32, Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY, 
            NOTIFICATION-TYPE            
                FROM SNMPv2-SMI            
            RowStatus, DateAndTime            
                FROM SNMPv2-TC;
    
    
        hwAlarmMIB MODULE-IDENTITY 
            LAST-UPDATED "201905211501Z"        -- May 21, 2019 at 15:01 GMT
            ORGANIZATION "Huawei Technologies Co.,Ltd."
            CONTACT-INFO 
                "Huawei Industrial Base
                  Bantian, Longgang
                   Shenzhen 518129
                   People's Republic of China
                   Website: http://www.huawei.com
                   Email: support@huawei.com"
            DESCRIPTION 
                "The MIB module for creating and deleting bulk files of
                SNMP data for file transfer." 
            REVISION "201905211501Z"        -- May 21, 2019 at 15:01 GMT
            DESCRIPTION
                "Add hwApName  node."
            REVISION "201804111550Z"        -- April 11, 2018 at 15:50 GMT
            DESCRIPTION
                "Modified hwSnmpTargetAddrExtIndex node."
            REVISION "201709200950Z"        -- September 20, 2017 at 9:50 GMT
            DESCRIPTION
                "Add hwAlarmVNFCName for trap."
            REVISION "201707141136Z"        -- July 14, 2017 at 11:36 GMT
            DESCRIPTION
                "Revert to the revision 2.10."
            REVISION "201702160943Z"        -- February 16, 2017 at 9:43 GMT
            DESCRIPTION
                "Revert to the revision 2.10."
            REVISION "201310280943Z"        -- October 28, 2013 at 9:43 GMT
            DESCRIPTION
                "Revert to the revision 2.10."
            REVISION "201310181643Z"        -- October 18, 2013 at 16:43 GMT
            DESCRIPTION
                "Add history alarm MIB."
            REVISION "200912051150Z"        -- December 05, 2009 at 11:50 GMT
            DESCRIPTION
                "The initial revision of this MIB module ."
            ::= { hwDatacomm 180 }  
    
--
-- Node definitions
--
        hwAlarmObjects OBJECT IDENTIFIER ::= { hwAlarmMIB 1 }
        
        hwSnmpTargetAddrExtTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwSnmpTargetAddrExtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Define snmp target Address extend table."
            ::= { hwAlarmObjects 1 }
        
        hwSnmpTargetAddrExtEntry OBJECT-TYPE
            SYNTAX HwSnmpTargetAddrExtEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of the extended snmp target address table."
            INDEX { IMPLIED hwSnmpTargetAddrExtIndex }
            ::= { hwSnmpTargetAddrExtTable 1 }
        
        HwSnmpTargetAddrExtEntry ::=
            SEQUENCE { 
                hwSnmpTargetAddrExtIndex
                    OCTET STRING,
                hwSnmpTargetSlaveAddressList
                    OCTET STRING,
                hwSnmpTargetAddrReliability
                    INTEGER,
                hwSnmpTargetAddrAlarmReliability
                    INTEGER,
                hwSnmpTargetAddrEventReliability
                    INTEGER,
                hwSnmpTargetAddrExtRowStatus 
                    RowStatus
             }

        hwSnmpTargetAddrExtIndex OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..128))
            MAX-ACCESS accessible-for-notify
            STATUS current
            DESCRIPTION
                "the extended target address table index."
            ::= { hwSnmpTargetAddrExtEntry 1 }
        
        hwSnmpTargetSlaveAddressList OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..255))
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Address of slave target host."
            ::= { hwSnmpTargetAddrExtEntry 2 }
        
        hwSnmpTargetAddrReliability OBJECT-TYPE
            SYNTAX INTEGER
                {
                enable(1),
                disable(2)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "If enable, then the extend VBs will be added to the alarm parameters. "
            DEFVAL { enable }
            ::= { hwSnmpTargetAddrExtEntry 3 }
        
        hwSnmpTargetAddrAlarmReliability OBJECT-TYPE
            SYNTAX INTEGER
                {
                enable(1),
                disable(2)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Alarm reliability function enable flag."
            DEFVAL { enable }
            ::= { hwSnmpTargetAddrExtEntry 4 }
        
        hwSnmpTargetAddrEventReliability OBJECT-TYPE
            SYNTAX INTEGER
                {
                enable(1),
                disable(2)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Event reliability function enable flag. "
            DEFVAL { enable }
            ::= { hwSnmpTargetAddrExtEntry 5 }
            
        hwSnmpTargetAddrExtRowStatus OBJECT-TYPE
           SYNTAX RowStatus
           MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "The row status of the target extend table."
            ::= { hwSnmpTargetAddrExtEntry 6 }
            
        hwMinAlarmSyncIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The minimal index value for alarm synchronization."
            ::= { hwAlarmObjects 2 }
        
        hwMaxAlarmSyncIndex OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The maximal index value for alarm synchronization. "
            ::= { hwAlarmObjects 3 }
        hwAlarmSyncTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmSyncEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Alarm synchronization table. "
            ::= { hwAlarmObjects 4 }
        
        hwAlarmSyncEntry OBJECT-TYPE
            SYNTAX HwAlarmSyncEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Alarm synchronization table entry."
            INDEX { hwSnmpTargetAddrExtIndex, hwAlarmSyncIndex }
            ::= { hwAlarmSyncTable 1 }
        
        HwAlarmSyncEntry ::=
            SEQUENCE { 
                hwAlarmSyncIndex
                    Unsigned32,
                hwAlarmSyncId
                    Counter64,
                hwAlarmSyncPara
                    OCTET STRING
             }

        hwAlarmSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Alarm synchronization index."
            ::= { hwAlarmSyncEntry 1 }
        
        hwAlarmSyncId OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Alarm id "
            ::= { hwAlarmSyncEntry 2 }
        
        hwAlarmSyncPara OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..4096))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the information contained 
                in the binding variable list of the alarm message."
            ::= { hwAlarmSyncEntry 3 }
        
        hwMinEventSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The minimal index value for event synchronization."
            ::= { hwAlarmObjects 5 }
        
        hwMaxEventSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The maximal index value for event synchronization. "
            ::= { hwAlarmObjects 6 }
        
        hwEventSyncTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventSyncEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event synchronization table."
            ::= { hwAlarmObjects 7 }
        
        hwEventSyncEntry OBJECT-TYPE
            SYNTAX HwEventSyncEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event synchronization table entry."
            INDEX { hwSnmpTargetAddrExtIndex, hwEventSyncIndex }
            ::= { hwEventSyncTable 1 }
        
        HwEventSyncEntry ::=
            SEQUENCE { 
                hwEventSyncIndex
                    Unsigned32,
                hwEventSyncId
                    Counter64,
                hwEventSyncPara
                    OCTET STRING
             }

        hwEventSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event synchronization index value."
            ::= { hwEventSyncEntry 1 }
        
        hwEventSyncId OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The event id."
            ::= { hwEventSyncEntry 2 }
        
        hwEventSyncPara OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..4096))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the information contained 
                in the binding variable list of an event."
            ::= { hwEventSyncEntry 3 }
        
        hwAlarmActiveTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmActiveEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The active alarm table."
            ::= { hwAlarmObjects 8 }
        
        hwAlarmActiveEntry OBJECT-TYPE
            SYNTAX HwAlarmActiveEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entries appear in this table when alarms are raised.  They
                are removed when the alarm is cleared."
            INDEX { hwSnmpTargetAddrExtIndex, hwActiveAlarmIndex }
            ::= { hwAlarmActiveTable 1 }
        
        HwAlarmActiveEntry ::=
            SEQUENCE { 
                hwActiveAlarmIndex
                    Unsigned32,
                hwActiveAlarmId
                    Counter64,
                hwActiveAlarmPara
                    OCTET STRING,
                hwActiveAlarmRowStatus
                    RowStatus
             }

        hwActiveAlarmIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A strictly monotonically increasing integer which acts as the index of all alarms and events. 
                It wraps back to 1 after it reaches its maximum value."
            ::= { hwAlarmActiveEntry 1 }
        
        hwActiveAlarmId OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The id of an alarm."
            ::= { hwAlarmActiveEntry 2 }
        
        hwActiveAlarmPara OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..4096))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the parameters of an active alarm."
            ::= { hwAlarmActiveEntry 3 }
        
        hwActiveAlarmRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the row status."
            ::= { hwAlarmActiveEntry 4 }
        
        hwEventTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event table. "
            ::= { hwAlarmObjects 9 }
        
        hwEventEntry OBJECT-TYPE
            SYNTAX HwEventEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entries appear in this table when events are raised."
            INDEX { hwSnmpTargetAddrExtIndex, hwEventIndex }
            ::= { hwEventTable 1 }
        
        HwEventEntry ::=
            SEQUENCE { 
                hwEventIndex
                    Unsigned32,
                hwEventId
                    Counter64,
                hwEventPara
                    OCTET STRING,
                hwEventRowStatus
                    RowStatus
             }

        hwEventIndex OBJECT-TYPE
            SYNTAX Unsigned32 (1..2147483647)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A strictly monotonically increasing integer 
                which acts as the index of all alarms and events. 
                It wraps back to 1 after it reaches its maximum value."
            ::= { hwEventEntry 1 }
        
        hwEventId OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the OID of an event."
            ::= { hwEventEntry 2 }
        
        hwEventPara OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..4096))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the parameter information of an event."
            ::= { hwEventEntry 3 }
        
        hwEventRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the row status."
            ::= { hwEventEntry 4 }
        
        hwAlarmDateAndTime OBJECT-TYPE
            SYNTAX DateAndTime
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the time when an alarm is generated or cleared."
            ::= { hwAlarmObjects 18 }
        
        hwAlarmOrEventFlag OBJECT-TYPE
            SYNTAX INTEGER
                {
                alarm(1),
                event(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Indicates the type of alarm messages.
                1: Alarm
                2: Event
                "
            ::= { hwAlarmObjects 19 }
        
        hwAlarmReasonInfo OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..255))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The reason for the alarm."
            ::= { hwAlarmObjects 20 }
        
        hwAlarmSeverity OBJECT-TYPE
            SYNTAX INTEGER
                {
                critical(1),
                major(2),
                minor(3),
                warning(4),
                indeterminate(5),
                cleared(6)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Alarm severity."
            ::= { hwAlarmObjects 25 }        
 
        hwAlarmVNFCName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " Alarm VNFC name."
            ::= { hwAlarmObjects 26 }

        hwSnmpTargetSyncIndexTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwSnmpTargetSyncIndexEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The synchronization index of snmp targets table."
            ::= { hwAlarmObjects 28 }
        
        hwSnmpTargetSyncIndexEntry OBJECT-TYPE
            SYNTAX HwSnmpTargetSyncIndexEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of the synchronization index table."
            INDEX { hwSnmpTargetAddrExtIndex }
            ::= { hwSnmpTargetSyncIndexTable 1 }
        
        HwSnmpTargetSyncIndexEntry ::=
            SEQUENCE { 
                hwMinAlmSyncIndex
                    Unsigned32,
                hwMaxAlmSyncIndex
                    Unsigned32,
                hwMinEvtSyncIndex
                    Unsigned32,
                hwMaxEvtSyncIndex
                    Unsigned32
             }

        hwMinAlmSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The minimal index value for alarm synchronization."
            ::= { hwSnmpTargetSyncIndexEntry 1 }
        
        hwMaxAlmSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The maximal index value for alarm synchronization. "
            ::= { hwSnmpTargetSyncIndexEntry 2 }
        
        hwMinEvtSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The minimal index value for event synchronization."
            ::= { hwSnmpTargetSyncIndexEntry 3 }
        
        hwMaxEvtSyncIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The maximal index value for event synchronization. "
            ::= { hwSnmpTargetSyncIndexEntry 4 }
        
        hwAlarmActiveVsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmActiveVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The active alarm management table for LSVS support version. "
            ::= { hwAlarmObjects 31 }
        
        hwAlarmActiveVsEntry OBJECT-TYPE
            SYNTAX HwAlarmActiveVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The active alarm table for VS support version. "
            AUGMENTS { hwAlarmActiveEntry }
            ::= { hwAlarmActiveVsTable 1 }
        
        HwAlarmActiveVsEntry ::=
            SEQUENCE { 
                hwAlarmActiveVsId
                    Unsigned32
             }

        hwAlarmActiveVsId OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The VS id of the alarm. "
            ::= { hwAlarmActiveVsEntry 9 }
        
        hwEventVsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event table for LSVS support version. "
            ::= { hwAlarmObjects 33 }
        
        hwEventVsEntry OBJECT-TYPE
            SYNTAX HwEventVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event entry."
            AUGMENTS { hwEventEntry }
            ::= { hwEventVsTable 1 }
        
        HwEventVsEntry ::=
            SEQUENCE { 
                hwEventVsId
                    Unsigned32
             }

        hwEventVsId OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The VS id of the event. "
            ::= { hwEventVsEntry 9 }
        
        hwAlarmSyncVsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmSyncVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Alarm synchronization table. "
            ::= { hwAlarmObjects 36 }
        
        hwAlarmSyncVsEntry OBJECT-TYPE
            SYNTAX HwAlarmSyncVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Alarm synchronization table entry."
            AUGMENTS { hwAlarmSyncEntry }
            ::= { hwAlarmSyncVsTable 1 }
        
        HwAlarmSyncVsEntry ::=
            SEQUENCE { 
                hwAlarmSyncVsId
                    Unsigned32
             }

        hwAlarmSyncVsId OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Alarm VS id."
            ::= { hwAlarmSyncVsEntry 3 }
        
        hwEventSyncVsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventSyncVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event synchronization table."
            ::= { hwAlarmObjects 39 }
        
        hwEventSyncVsEntry OBJECT-TYPE
            SYNTAX HwEventSyncVsEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The event synchronization table entry."
            AUGMENTS { hwEventSyncEntry }
            ::= { hwEventSyncVsTable 1 }
        
        HwEventSyncVsEntry ::=
            SEQUENCE { 
                hwEvevtSyncVsId
                    Unsigned32
             }

        hwEvevtSyncVsId OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The VS id of the event."
            ::= { hwEventSyncVsEntry 3 }

        hwApName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..246))
            MAX-ACCESS accessible-for-notify
            STATUS current
            DESCRIPTION
                "Alarm AP name."
           ::= { hwAlarmObjects 40 }
                
        hwAlarmNotifications OBJECT IDENTIFIER ::= { hwAlarmMIB 2 }
        
        hwAlarmTargetHostDel NOTIFICATION-TYPE
            OBJECTS { hwSnmpTargetAddrExtIndex }
            STATUS current
            DESCRIPTION 
                "The notification for the deletion of the target host. "
            ::= { hwAlarmNotifications 1 }
        
        hwAlarmStorm NOTIFICATION-TYPE
            STATUS current
            DESCRIPTION 
                "The alarm storm notification."
            ::= { hwAlarmNotifications 2 }
        hwAlarmConformance OBJECT IDENTIFIER ::= { hwAlarmMIB 3 }
        
        hwAlarmCompliances OBJECT IDENTIFIER ::= { hwAlarmConformance 1 }
        
        hwAlarmCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION 
                "The compliance statement for entities which 
                implement the Huawei Alarm mib."
            MODULE -- this module
                MANDATORY-GROUPS { hwAlarmReliabilityGroup }
            ::= { hwAlarmCompliances 1 }
        
        hwAlarmGroups OBJECT IDENTIFIER ::= { hwAlarmConformance 2 }
        
        hwAlarmReliabilityGroup OBJECT-GROUP
            OBJECTS { hwSnmpTargetSlaveAddressList, hwSnmpTargetAddrEventReliability, hwSnmpTargetAddrAlarmReliability, hwSnmpTargetAddrReliability, hwSnmpTargetAddrExtRowStatus
                 }
            STATUS current
            DESCRIPTION 
                "The objects for alarm reliability and snmp target address list."
            ::= { hwAlarmGroups 1 }
        
        hwActiveInfoGroup OBJECT-GROUP
            OBJECTS { hwActiveAlarmId, hwActiveAlarmPara, hwEventRowStatus, hwActiveAlarmRowStatus, hwEventId, 
                hwEventPara }
            STATUS current
            DESCRIPTION 
                "The nodes for querying the  active alarm information."
            ::= { hwAlarmGroups 7 }
        
        hwTrapInfoSyncGroup OBJECT-GROUP
            OBJECTS { hwMinAlarmSyncIndex, hwMaxAlarmSyncIndex, hwAlarmSyncId, hwAlarmSyncPara, hwMinEventSyncIndex, 
                hwMaxEventSyncIndex, hwEventSyncId, hwEventSyncPara, hwAlarmDateAndTime, hwAlarmCorrAnalyzeSuppressionRootCauseIndication,
                hwAlarmCorrAnalyzeSuppressionParentSequence, hwAlarmReasonInfo, hwAlarmSeverity, hwAlarmOrEventFlag }
            STATUS current
            DESCRIPTION 
                "All information of trap synchronization."
            ::= { hwAlarmGroups 8 }
        
        hwActiveInfoVsGroup OBJECT-GROUP
            OBJECTS { hwAlarmActiveVsId, hwEventVsId }
            STATUS current
            DESCRIPTION 
                "The VS id of the active alarm or event."
            ::= { hwAlarmGroups 9 }
        
        hwTrapSyncVsGroup OBJECT-GROUP
            OBJECTS { hwAlarmSyncVsId, hwEvevtSyncVsId, hwMinAlmSyncIndex, hwMaxAlmSyncIndex, hwMinEvtSyncIndex, 
                hwMaxEvtSyncIndex }
            STATUS current
            DESCRIPTION 
                "The VS id and the synchronization sequence number nodes."
            ::= { hwAlarmGroups 10 }
        
        hwAlarmTrapInfoGroup NOTIFICATION-GROUP
            NOTIFICATIONS { hwAlarmTargetHostDel, hwAlarmStorm }
            STATUS current
            DESCRIPTION 
                "Alarm trap nodes."
            ::= { hwAlarmGroups 11 }
            
        hwTrapSuppressionGroup OBJECT-GROUP
            OBJECTS { hwAlarmDelaySuppressionEnable, hwAlarmDelaySuppressionCausePersistPeriod, hwAlarmDelaySuppressionClearPersistPeriod,
            hwAlarmCorrAnalyzeSuppressionEnable, hwAlarmCorrAnalyzeSuppressionStatus, hwEventDelaySuppressionEnable, hwEventDelaySuppressionCausePersistPeriod }
            STATUS current
            DESCRIPTION 
                "The trap suppression nodes."
            ::= { hwAlarmGroups 12 }
        
        hwTrapInfoGroup OBJECT-GROUP
            OBJECTS { hwAlarmAttrSeverity, hwEventAttrSeverity }
            STATUS current
            DESCRIPTION 
                "The basal information of trap nodes."
            ::= { hwAlarmGroups 13 }
        
        hwAlarmConfig OBJECT IDENTIFIER ::= { hwAlarmMIB 5 }
        
        hwAlarmAttr OBJECT IDENTIFIER ::= { hwAlarmConfig 1 }
        
        hwAlarmAttrTable OBJECT-TYPE
          SYNTAX SEQUENCE OF HwAlarmAttrEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "This table contains attribute of alarms."
          ::= {hwAlarmAttr 1}

        hwAlarmAttrEntry OBJECT-TYPE
          SYNTAX HwAlarmAttrEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "Entry of hwAlarmAttrTable."
          INDEX {hwAlarmName}
          ::= {hwAlarmAttrTable 1}

        HwAlarmAttrEntry::=
          SEQUENCE {                  
                  hwAlarmName  
                  OCTET STRING,
                  hwAlarmAttrSeverity  
                  INTEGER
               }  
          
        hwAlarmName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..64))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The name of registered alarms."
            ::= { hwAlarmAttrEntry 1 }  
      
        hwAlarmAttrSeverity OBJECT-TYPE
            SYNTAX INTEGER
                     { 
                      critical(1),
                      major(2),
                      minor(3),
                      warning(4),
                      indeterminate(5),
                      cleared(6)
                     } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The severity of alarms."
            ::= { hwAlarmAttrEntry 2 }
            
            
        hwAlarmMask  OBJECT IDENTIFIER ::= { hwAlarmConfig 3 }
        
        hwAlarmMaskBasedOnIfnameTable OBJECT-TYPE
          SYNTAX SEQUENCE OF HwAlarmMaskBasedOnIfnameEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "Define alarm mask table, which is based on interface."
          ::= {hwAlarmMask 1}

        hwAlarmMaskBasedOnIfnameEntry OBJECT-TYPE
          SYNTAX HwAlarmMaskBasedOnIfnameEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "Entry of hwAlarmMaskBasedOnIfnameTable."
          INDEX {hwAlarmMaskIfName}
          ::= {hwAlarmMaskBasedOnIfnameTable 1}
          
        HwAlarmMaskBasedOnIfnameEntry::=        
            SEQUENCE {   
                     hwAlarmMaskIfName  
                           OCTET STRING,
                     hwAlarmMaskBasedOnIfnameRowStatus  
                           RowStatus
                  }
                  
        hwAlarmMaskIfName OBJECT-TYPE
            SYNTAX OCTET STRING  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The interface name for alarm mask."
            ::= { hwAlarmMaskBasedOnIfnameEntry 1 }
          
        hwAlarmMaskBasedOnIfnameRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "The row status of the alarm mask based on interface table."
            ::= { hwAlarmMaskBasedOnIfnameEntry 51 } 
        
        hwAlarmMaskBasedOnEntityTable OBJECT-TYPE
          SYNTAX SEQUENCE OF HwAlarmMaskBasedOnEntityEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "Define alarm mask table, which is based on entity index."
          ::= {hwAlarmMask 2}

        hwAlarmMaskBasedOnEntityEntry OBJECT-TYPE
          SYNTAX HwAlarmMaskBasedOnEntityEntry
          MAX-ACCESS not-accessible
          STATUS current
          DESCRIPTION
              "Entry of hwAlarmMaskBasedOnEntityTable."
          INDEX {hwAlarmMaskEntPhysicalIndex}
          ::= {hwAlarmMaskBasedOnEntityTable 1}
          
        HwAlarmMaskBasedOnEntityEntry::=        
            SEQUENCE {   
                     hwAlarmMaskEntPhysicalIndex  
                           Integer32,
                     hwAlarmMaskEntPhysicalName  
                           OCTET STRING,
                     hwAlarmMaskBasedOnEntityRowStatus  
                           RowStatus
                  }
                  
        hwAlarmMaskEntPhysicalIndex OBJECT-TYPE
            SYNTAX Integer32  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The physical index of entity for alarm mask."
            ::= { hwAlarmMaskBasedOnEntityEntry 1 }
            
        hwAlarmMaskEntPhysicalName OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The physical name of entity for alarm mask."
            ::= { hwAlarmMaskBasedOnEntityEntry 2 }
          
        hwAlarmMaskBasedOnEntityRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "The row status of the alarm mask based on entity table."
            ::= { hwAlarmMaskBasedOnEntityEntry 51 }  
               
        hwAlarmDelay OBJECT IDENTIFIER ::= { hwAlarmConfig 4 } 
        
        hwAlarmDelaySuppressionEnable OBJECT-TYPE
            SYNTAX INTEGER
            {
                enable(1),
                disable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The switch of alarm delay suppression."
            DEFVAL { enable }
            ::= { hwAlarmDelay 1 }

        
        hwAlarmDelaySuppressionTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmDelaySuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Define alarm delay suppression table."
            ::= { hwAlarmDelay 2 }
        
        hwAlarmDelaySuppressionEntry OBJECT-TYPE
            SYNTAX HwAlarmDelaySuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of the alarm delay suppression table."
            INDEX { hwAlarmName }
            ::= { hwAlarmDelaySuppressionTable 1 }   
        
        HwAlarmDelaySuppressionEntry::=
            SEQUENCE {                  
                  hwAlarmDelaySuppressionCausePersistPeriod
                  Integer32,   
                  hwAlarmDelaySuppressionClearPersistPeriod
                  Integer32
               }  
            
        hwAlarmDelaySuppressionCausePersistPeriod OBJECT-TYPE
            SYNTAX Integer32 (0..600)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The cause persist period of alarm delay suppression."
            ::= { hwAlarmDelaySuppressionEntry 1 }
        
        hwAlarmDelaySuppressionClearPersistPeriod OBJECT-TYPE
            SYNTAX Integer32 (0..600)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The clear persist period of alarm delay suppression."
            ::= { hwAlarmDelaySuppressionEntry 2 }        
        
        hwAlarmCorrAnalyze OBJECT IDENTIFIER ::= { hwAlarmConfig 5 } 
        
        hwAlarmCorrAnalyzeSuppressionEnable OBJECT-TYPE
            SYNTAX INTEGER
            {
                enable(1),
                disable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The switch of alarm correlation analyze suppression."
            DEFVAL { disable }
            ::= { hwAlarmCorrAnalyze 1 }
        
         
         hwAlarmCorrAnalyzeSuppressionRootCauseIndication OBJECT-TYPE
            SYNTAX INTEGER
                {
                    independent(0),
                    rootcause(1),
                    nonrootcause(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "If alarm has passed correaltion analysis, this indication is 
                 rootcause or nonrootcause, default is independent."
            ::= { hwAlarmCorrAnalyze 2 }
        
        hwAlarmCorrAnalyzeSuppressionParentSequence OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The parent sequence of alarm, whose indication is nonrootcause."
            ::= { hwAlarmCorrAnalyze 3 }
       
        hwAlarmCorrAnalyzeSuppressionTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwAlarmCorrAnalyzeSuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Define alarm correlation analyze suppression table."
            ::= { hwAlarmCorrAnalyze 4 }
        
        hwAlarmCorrAnalyzeSuppressionEntry OBJECT-TYPE
            SYNTAX HwAlarmCorrAnalyzeSuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of alarm correlation analyze suppression table."
            INDEX { hwSnmpTargetAddrExtIndex }
            ::= { hwAlarmCorrAnalyzeSuppressionTable 1 }           
            
        HwAlarmCorrAnalyzeSuppressionEntry ::=
            SEQUENCE { 
                hwAlarmCorrAnalyzeSuppressionStatus  
                INTEGER                                     
                     }   
            
        hwAlarmCorrAnalyzeSuppressionStatus OBJECT-TYPE
            SYNTAX INTEGER 
              {               
                  enable(1),
                  disable(2)
              } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The status of alarm correlation suppression for each target host."
            ::= { hwAlarmCorrAnalyzeSuppressionEntry 1 }  
        
        hwEventConfig OBJECT IDENTIFIER ::= { hwAlarmMIB 6 }
        
        hwEventAttr OBJECT IDENTIFIER ::= { hwEventConfig 1 }
        
        hwEventAttrTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventAttrEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "This table contains attribute of events."
            ::= {hwEventAttr 1}
    
        hwEventAttrEntry OBJECT-TYPE
            SYNTAX HwEventAttrEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Entry of hwEventAttrTable."
            INDEX {hwEventName}
            ::= {hwEventAttrTable 1}

        HwEventAttrEntry::=
            SEQUENCE {                  
                  hwEventName  OCTET STRING,   
                  hwEventAttrSeverity INTEGER
               }  
          
        hwEventName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (1..64))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The name of registered events."
            ::= { hwEventAttrEntry 1 }  
                 
        hwEventAttrSeverity OBJECT-TYPE
            SYNTAX INTEGER
                     {
                      critical(1),
                      major(2),
                      minor(3),
                      warning(4),
                      indeterminate(5),
                      cleared(6)
                     } 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The severity of evens."
            ::= { hwEventAttrEntry 2 }
                
        hwEventDelay OBJECT IDENTIFIER ::= { hwEventConfig 4 }  
        
        hwEventDelaySuppressionEnable OBJECT-TYPE
            SYNTAX INTEGER
            {
                enable(1),
                disable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The switch of event delay suppression."
            DEFVAL { enable }
            ::= { hwEventDelay 1 }
        
        
        hwEventDelaySuppressionTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEventDelaySuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Define event delay suppression table."
            ::= { hwEventDelay 2 }
        
        hwEventDelaySuppressionEntry OBJECT-TYPE
            SYNTAX HwEventDelaySuppressionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry of event delay suppression table."
            INDEX { hwEventName }
            ::= { hwEventDelaySuppressionTable 1 }
            
        HwEventDelaySuppressionEntry::=
            SEQUENCE {                  
                         hwEventDelaySuppressionCausePersistPeriod 
                         Integer32  
                     }  
            
        hwEventDelaySuppressionCausePersistPeriod OBJECT-TYPE
            SYNTAX Integer32 (0..600)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The cause persist period of event delay suppression."
            ::= { hwEventDelaySuppressionEntry 1 }
    END

--
-- HUAWEI-ALARM-MIB.mib
--