librenms/librenms

View on GitHub
mibs/huawei/HUAWEI-MODULE-INFO-MIB

Summary

Maintainability
Test Coverage
--  ====================================================================
-- Copyright (C) 2005 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- 
-- Description: Huawei Module information MIB Definition
-- Reference:   
-- Version:     V1.0
-- History:
--              huruoheng create first version v1.0
-- =====================================================================

HUAWEI-MODULE-INFO-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        hwDatacomm            
            FROM HUAWEI-MIB            
        OBJECT-TYPE,  MODULE-IDENTITY            
            FROM SNMPv2-SMI            
        DateAndTime, TEXTUAL-CONVENTION
            FROM SNMPv2-TC            
        SnmpAdminString
            FROM SNMP-FRAMEWORK-MIB;

    hwModuleInfo MODULE-IDENTITY 
        LAST-UPDATED "200506301600Z"        
        ORGANIZATION 
            "Huawei Technologies Co., Ltd."
        CONTACT-INFO 
            "R&D BeiJing, Huawei Technologies co.,Ltd.
            Huawei Bld.,NO.3 Xinxi Rd., 
            Shang-Di Information Industry Base,
            Hai-Dian District Beijing P.R. China
            Zip:100085 
            Http://www.huawei.com                                       
            E-mail:support@huawei.com"
        DESCRIPTION 
            "
            The HUAWEI-MODULE-INFO-MIB contains objects to describe
            the module information.Such as module BOM description string.
            "
        ::= { hwDatacomm 43 }

    hwModuleInfoObjects OBJECT IDENTIFIER ::= { hwModuleInfo 1 }

    hwModuleInfoTable OBJECT-TYPE
        SYNTAX SEQUENCE OF HwModuleInfoEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "This table contains the Module Information about slot and subslot."
        ::= { hwModuleInfoObjects 1 }
    
    hwModuleInfoEntry OBJECT-TYPE
        SYNTAX HwModuleInfoEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "An entry in this table."
        INDEX { hwModuleIndex, hwSubModuleIndex }
        ::= { hwModuleInfoTable 1 }
    
    HwModuleInfoEntry ::=
        SEQUENCE { 
            hwModuleIndex
                INTEGER,
            hwSubModuleIndex
                INTEGER,                
            hwModuleBomId
                SnmpAdminString,
            hwModuleBomEnDesc
                SnmpAdminString,
            hwModuleBomLocalDesc
                SnmpAdminString,
            hwModuleManufacturedDate
                DateAndTime,
            hwModuleManufactureCode
                INTEGER,
            hwModuleCLEICode
                SnmpAdminString,
            hwModuleUpdateLog
                SnmpAdminString,
            hwModuleArchivesInfoVersion
                SnmpAdminString,
            hwModuleSerialNum
                SnmpAdminString
         }
         
         
    hwModuleIndex OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "
            Object to index the table.It can be integer up from 1.
            For example: 3 means the entry is a module from No.3 slot
            and it can be slot or subslot.
            "
        ::= { hwModuleInfoEntry 1 }
        
    hwSubModuleIndex OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "
            Sub Object to index the table.It can be integer up from 1.
            
            For example: 
            
            hwModuleIndex=1    hwSubModuleIndex=5
            That means this entry is the fifth subslot on slot No.1
            
            hwModuleIndex=2    hwSubModuleIndex=0
            That means this entry is the second slot,and not a subslot.
            "
        ::= { hwModuleInfoEntry 2 }
         
    hwModuleBomId OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The identity of the Bill of Material about this replaceable 
            unit which coded by vendor. This node is mapping to 'ITEM' 
            in the information file.
            "
        ::= { hwModuleInfoEntry 3 }
        
    hwModuleBomEnDesc OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The English description of the Bill of Material about this 
            replaceable unit.
            "
        ::= { hwModuleInfoEntry 4 }
        
    hwModuleBomLocalDesc OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The local description of the Bill of Material about this 
            replaceable unit.
            "
        ::= { hwModuleInfoEntry 5 }        
        
    hwModuleManufacturedDate OBJECT-TYPE
        SYNTAX DateAndTime
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The date when this physical entity is Manufactured.
            "
        ::= { hwModuleInfoEntry 6 }        
        
    hwModuleManufactureCode OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The code of the place where this physical entity is Manufactured.
            "
        ::= { hwModuleInfoEntry 7 }        
        
    hwModuleCLEICode OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The string code of CLEI which was granted by America.
            "
        ::= { hwModuleInfoEntry 8 }        
        
    hwModuleUpdateLog OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The maintenance log of this replaceable unit.
            "
        ::= { hwModuleInfoEntry 9 }         
        
    hwModuleArchivesInfoVersion OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The Version of Archives Information.
            "
        ::= { hwModuleInfoEntry 10 }        
        
    hwModuleSerialNum OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The Serial number of this replaceable unit.
            "
        ::= { hwModuleInfoEntry 11 }                
            
         
         
END