librenms/librenms

View on GitHub
mibs/huawei/HUAWEI-MPLSLSR-EXT-MIB

Summary

Maintainability
Test Coverage
-- ===================================================================
-- Copyright (C) 2013 by HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This MIB provides management of MPLS basic configurations.
--              It is an extension of MPLS-LSR-STD-MIB.
-- Reference:
-- Version: V2.01
-- History:
-- V2.01 ZhangAiFen, 2013-09-24, revision
-- ===================================================================
-- ==================================================================
-- 
-- Variables and types be imported
-- 
-- ==================================================================

    HUAWEI-MPLSLSR-EXT-MIB DEFINITIONS ::= BEGIN
 
        IMPORTS
            hwDatacomm            
                FROM HUAWEI-MIB            
            InterfaceIndex            
                FROM IF-MIB            
            OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE            
                FROM SNMPv2-CONF            
            MplsLabel
                FROM MPLS-TC-STD-MIB                               -- [RFC3811]
            EnabledStatus
                FROM P-BRIDGE-MIB            
            DisplayString, RowStatus                        
                FROM SNMPv2-TC
            Integer32, IpAddress, OBJECT-TYPE, Unsigned32, 
            MODULE-IDENTITY, NOTIFICATION-TYPE            
                FROM SNMPv2-SMI;
    
         hwMplsLsrExtMIB MODULE-IDENTITY 
            LAST-UPDATED "201309241655Z"        -- Sep 24, 2013 at 16:55 GMT
            ORGANIZATION 
                "Huawei Technologies Co.,Ltd."
            CONTACT-INFO 
                "Huawei Industrial Base
                  Bantian, Longgang
                   Shenzhen 518129
                   People's Republic of China 
                   Website: http://www.huawei.com
                   Email: support@huawei.com
                  "
            DESCRIPTION 
                "This MIB provides management of MPLS basic configurations. 
                It is an extension of MPLS-LSR-STD-MIB."                

-- Revision history
         REVISION    "201309241655Z"  
         DESCRIPTION "V2.01, added six nodes about MPLS BGP BFD configuration management."

         REVISION    "201107301100Z"  
         DESCRIPTION "V2.00, delete Delval clause in these nodes: hwMplsLabelAdvertise, hwLdpVirtualStatus."
 
         REVISION    "201011221600Z"  
         DESCRIPTION "V1.03, modified the description."
     
         REVISION    "201008111600Z"  
         DESCRIPTION "V1.02, modified the description."
                
         REVISION    "201007121600Z"  
         DESCRIPTION "V1.01, added the object hwMplsStaticLspTable and modified the description."
                   
         REVISION    "200903101600Z"  
         DESCRIPTION "V1.00, initial version for the configuration of MPLS capabilities."
         ::= { hwDatacomm 182 }

--
-- Node definitions
--
    
        hwMplsLsrExtObject OBJECT IDENTIFIER ::= { hwMplsLsrExtMIB 1 }

             
        hwMplsLsrId OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the configuration of the MPLS LSR ID. 
                 Before the MPLS capability is enabled, the MPLS LSR ID must be configured. 
                 After the MPLS capability is enabled, the MPLS LSR ID cannot be modified or deleted. 
                 If the MPLS LSR ID is set as 0.0.0.0, it indicates that the MPLS LSR ID is deleted.
                 The MPLS LSR ID and the MPLS capability cannot be configured together."
            ::= { hwMplsLsrExtObject 1 }
            
        hwMplsCapabilityConfig OBJECT-TYPE
            SYNTAX EnabledStatus
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the configuration or deletion of the MPLS capability. 
                 Before the MPLS capability is enabled, the MPLS LSR ID must be configured."
            ::= { hwMplsLsrExtObject 2 }
            
        hwMplsLabelAdvertise OBJECT-TYPE
            SYNTAX INTEGER
            {
                explicitNull(1),
                implicitNull(2),
                nonNull(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the way to configure label advertisement policy. 
                 By default, the label advertisement policy is implicitnull. 
                 Before the label advertisement policy is configured, MPLS capability must be enabled.
                 Options:
                 1. explicitNull(1) -indicates that the label advertisement policy is explicitNull.
                 2. implicitNull(2) -indicates that the label advertisement policy is implicitNull.
                 3. nonNull(3)      -indicates that the label advertisement policy is nonNull.
                 Default: implicitNull(2)
                "
            ::= { hwMplsLsrExtObject 3 }
        hwMplsStatisticsIntervalTimer OBJECT-TYPE
            SYNTAX Integer32 (0..65535)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the value of the MPLS statistics timer.
                 Range: 30-65535
                 Default: 0
                 Unit: seconds
                "
            ::= { hwMplsLsrExtObject 4 }
        hwMplsBfdCapabilityConfig OBJECT-TYPE
            SYNTAX EnabledStatus
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the configuration or deletion of the MPLS BFD capability. 
                 Before the MPLS BFD function is enabled, you must enable the MPLS capability and BFD capability."
            ::= { hwMplsLsrExtObject 5 }
            
        hwMplsBfdMinTx OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the minimum forwarding period. 
                 If the minimum forwarding period is set as 0 seconds, 
                 it indicates that the minimum forwarding period returns to the default value."
            ::= { hwMplsLsrExtObject 6 }
            
        hwMplsBfdMinRx OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the minimum receiving period. 
                 If the minimum receiving period is set as 0 seconds, 
                 it indicates that the minimum receiving period returns to the default value."
            ::= { hwMplsLsrExtObject 7 }
            
        hwMplsBfdDetectMultiplier OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the value of the detect multiplier. 
                 If the value of the detect multiplier is set as 0, 
                 it indicates that the value returns to the default value."
            ::= { hwMplsLsrExtObject 8 }

        hwMplsFecListName OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the name of the FEC LIST. 
                 The name of the FEC LIST is globally unique, with a valid length from 1 to 31 characters. 
                 If the character length is 0, it indicates that the FEC LIST is deleted. 
                 Furthermore, the FEC LIST cannot be modified, and you can only delete the FEC LIST and then create a new one. 
                 If the FEC LIST is used by others, you need to cancel the usage and then delete the FEC LIST.
                 Range: 1-31
                "
            ::= { hwMplsLsrExtObject 9 }

        hwMplsBfdTrigger OBJECT-TYPE
            SYNTAX INTEGER
            {
                triggerHost(1),
                triggerFeclist(2),
                disabled(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the MPLS BFD triggering policy. 
                 By using this object, you can also specify the next hop and the outgoing interface. 
                 To configure the MPLS BFD triggering policy, you must enable MPLS and BFD in advance. 
                 In addition, this MPLS BFD triggering policy cannot be modified, 
                 and you can only delete the policy and then create a new one.
                 Options:
                 1. triggerHost(1)    -indicates that the MPLS BFD triggering policy was configured as host.
                 2. triggerFeclist(2) -indicates that the MPLS BFD triggering policy was configured as FEC list.
                 3. disabled(3)       -indicates that the MPLS BFD triggering policy was not configured.
                 Default: triggerHost(1)
                "
            ::= { hwMplsLsrExtObject 10 }
            
        hwMplsBfdTriggerNextHop OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the next hop when the MPLS BFD trigger policy is configured as host. 
                 The next hop and the outgoing interface can be specified at the same time."
            ::= { hwMplsLsrExtObject 11 }
            
        hwMplsBfdTriggerInterface OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the outgoing interface when the MPLS BFD trigger policy is configured as host. 
                 The next hop and the outgoing interface can be specified at the same time. 
                 In addition, you can get the correct interface index based on the ifIndex of ifTable."
            ::= { hwMplsLsrExtObject 12 }
            
        hwMplsBfdTriggerFecListName OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the FEC list when the MPLS BFD trigger policy is configured. 
                 The valid length of the FEC list ranges from 1 to 31 characters. 
                 If the specified FEC list does not exist, or the specified FEC list contains no FEC node, no LSP can be triggered.
                 Range: 1-31
                "
            ::= { hwMplsLsrExtObject 13 }

        hwLdpVirtualTunnelFEC OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS accessible-for-notify
            STATUS current
            DESCRIPTION
                "This object indicates the LDP virtual tunnel FEC."
            ::= { hwMplsLsrExtObject 14 }
              hwMplsBgpBfdCapabilityConfig OBJECT-TYPE
            SYNTAX EnabledStatus
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the configuration or deletion of the MPLS BGP BFD capability. 
                 Before the MPLS BGP BFD function is enabled, you must enable the MPLS capability and BFD capability."
            ::= { hwMplsLsrExtObject 15 }
            
        hwMplsBgpBfdMinTx OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the minimum forwarding period. 
                 If the minimum forwarding period is set as 0 seconds, 
                 it indicates that the minimum forwarding period returns to the default value."
            ::= { hwMplsLsrExtObject 16 }
            
        hwMplsBgpBfdMinRx OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the minimum receiving period. 
                 If the minimum receiving period is set as 0 seconds, 
                 it indicates that the minimum receiving period returns to the default value."
            ::= { hwMplsLsrExtObject 17 }
            
        hwMplsBgpBfdDetectMultiplier OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the value of the detect multiplier. 
                 If the value of the detect multiplier is set as 0, 
                 it indicates that the value returns to the default value."
            ::= { hwMplsLsrExtObject 18 }
            
        hwMplsBgpBfdTriggerTunnel OBJECT-TYPE
            SYNTAX INTEGER
            {
                triggerHost(1),
                triggerIpPrefix(2),
                disabled(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the MPLS BGP BFD triggering policy. 
                 To configure the MPLS BGP BFD triggering policy, you must enable MPLS and BFD in advance. 
                 Options:
                 1. triggerHost(1)    -indicates that the MPLS BGP BFD triggering policy was configured as host.
                 2. triggerIpPrefix(2) -indicates that the MPLS BGP BFD triggering policy was configured as Ip Prefix.
                 3. disabled(3)       -indicates that the MPLS BGP BFD triggering policy was not configured.
                 Default: disabled(3)
                "
            ::= { hwMplsLsrExtObject 19 }

        hwMplsBgpBfdTriggerTunnelIpprefix OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This object indicates the IP Prefix name when the MPLS BGP BFD trigger policy is configured. 
                 The valid length of the IP prefix name ranges from 1 to 169 characters. 
                 Range: 1-169
                "
            ::= { hwMplsLsrExtObject 20 }

-- Mpls Fec List Table

        hwMplsFecListTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwMplsFecListEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to configure or delete MPLS FEC Node.
                 The indexes of this table are hwMplsFecNodeIpAddress, hwMplsFecNodeInterface, and hwMplsFecNodeNextHop.
                "
            ::= { hwMplsLsrExtObject 50 }

        hwMplsFecListEntry OBJECT-TYPE
            SYNTAX HwMplsFecListEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An FEC node entry of FEC list table. It can be created, or deleted.
                 The indexes of this entry are hwMplsFecNodeIpAddress, hwMplsFecNodeInterface, and hwMplsFecNodeNextHop.
                "
            INDEX { hwMplsFecNodeIpAddress, hwMplsFecNodeInterface, hwMplsFecNodeNextHop }
            ::= { hwMplsFecListTable 1 }

        
        HwMplsFecListEntry ::=
            SEQUENCE { 
                hwMplsFecNodeIpAddress
                    IpAddress,
                hwMplsFecNodeInterface
                    Unsigned32,
                hwMplsFecNodeNextHop
                    IpAddress,
                hwMplsFecListRowStatus
                    RowStatus
             }
        hwMplsFecNodeIpAddress OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the IP address of the specified FEC node."
            ::= { hwMplsFecListEntry 2 }
            
        hwMplsFecNodeInterface OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the outgoing interface of the FEC node. 
                 You can get the correct interface index based on the ifIndex of ifTable."
            ::= { hwMplsFecListEntry 3 }
            
        hwMplsFecNodeNextHop OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the next hop of the FEC node."
            ::= { hwMplsFecListEntry 4 }
            
        hwMplsFecListRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates whether one entry of FEC list table is created or destroyed. 
                 The value of the object can be CreatAndGo or Destroy. 
                 If the value is set as CreatAndGo, and the entry is created in hwFecListTable, the status of the object will change into active."
            ::= { hwMplsFecListEntry 51 }
 
-- Mpls interface Table
 
         hwMplsInterfaceTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwMplsInterfaceEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to configure or delete the MPLS capability on the interface.
                 The index of this table is hwMplsInterfaceIndex.
                "
            ::= { hwMplsLsrExtObject 51 }

        hwMplsInterfaceEntry OBJECT-TYPE
            SYNTAX HwMplsInterfaceEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An entry of the MPLS interface table, used to display and configure features on the MPLS-supporting interface.
                 The index of this entry is hwMplsInterfaceIndex.
                "
            INDEX {hwMplsInterfaceIndex }
            ::= { hwMplsInterfaceTable 1 }

        
        HwMplsInterfaceEntry ::=
            SEQUENCE { 
                hwMplsInterfaceIndex
                    InterfaceIndex,
                hwMplsMtu
                    Integer32,
                hwMplsInterfaceRowStatus
                    RowStatus
             }
             
        hwMplsInterfaceIndex OBJECT-TYPE
            SYNTAX InterfaceIndex
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the interface index. 
                 You can get the correct interface index based on the ifIndex of ifTable."
            ::= { hwMplsInterfaceEntry 1 }
            

        hwMplsMtu OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the MPLS MTU of an interface. 
                 If the value of the MPLS MTU is set as 0, it indicates that the MPLS MTU is deleted."
            ::= { hwMplsInterfaceEntry 11 }

            
        hwMplsInterfaceRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates whether one entry is created or deleted in hwMplsInterfaceTable. 
                 The value of the object can be CreatAndGo and Destroy. 
                 When the value is set as CreatAndGo, and the entry is created, the status of the object will change into active."
            ::= { hwMplsInterfaceEntry 51 }
            
-- Ldp Static FRR interface Table

         hwLdpStaticFrrInterfaceTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwLdpStaticFrrInterfaceEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to configure or delete static LDP FRR entries on the interface.
                 The indexes of this table are hwMplsInterfaceIndex and hwLdpStaticFrrPriority.
                "
            ::= { hwMplsLsrExtObject 52 }

        hwLdpStaticFrrInterfaceEntry OBJECT-TYPE
            SYNTAX HwLdpStaticFrrInterfaceEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This entry is used to display and configure the FRR-supporting interface.
                 The indexes of this entry are hwMplsInterfaceIndex and hwLdpStaticFrrPriority.
                "
            INDEX {hwMplsInterfaceIndex,
                             hwLdpStaticFrrPriority }
            ::= { hwLdpStaticFrrInterfaceTable 1 }

        
        HwLdpStaticFrrInterfaceEntry ::=
            SEQUENCE { 
                hwLdpStaticFrrPriority
                    Integer32,
                hwLdpStaticFrrNextHop
                    IpAddress,
                hwLdpStaticFrrIpPrefix
                    DisplayString,
                hwLdpStaticFrrInterfaceRowStatus
                    RowStatus
             }
            
        hwLdpStaticFrrPriority OBJECT-TYPE
            SYNTAX Integer32 (1..65535)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the priority of a static FRR entry."
            ::= { hwLdpStaticFrrInterfaceEntry 1 }

        hwLdpStaticFrrNextHop OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the next hop of the static FRR."
            ::= { hwLdpStaticFrrInterfaceEntry 11 }
           
        hwLdpStaticFrrIpPrefix OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the IP prefix policy. 
                 The valid prefix length ranges from 1 to 169 characters. 
                 When the length is 0, it indicates that the policy is deleted.
                 Range: 1-169
                "
            ::= { hwLdpStaticFrrInterfaceEntry 12 }
            
        hwLdpStaticFrrInterfaceRowStatus OBJECT-TYPE
            SYNTAX RowStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates whether one entry is created or deleted in hwLdpStaticFrrInterfaceTable. 
                 The value of the object can be CreatAndGo or Destroy. 
                 When the value is set as CreatAndGo, and the entry is created, the status of the object will change into active."
            ::= { hwLdpStaticFrrInterfaceEntry 51 }           

-- Ldp Virtual Tunnel interface Table

        hwLdpVirtualTunnelTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwLdpVirtualTunnelEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table specifies LDP virtual tunnel information.
                 The index of this table is hwLdpVirtualTunnelIndex.
                "
            ::= { hwMplsLsrExtObject 53 }

        hwLdpVirtualTunnelEntry OBJECT-TYPE
            SYNTAX HwLdpVirtualTunnelEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An entry of the virtual tunnel table, used to display the features associated with the virtual tunnel.
                 The index of this entry is hwLdpVirtualTunnelIndex.
                "
            INDEX { hwLdpVirtualTunnelIndex }
            ::= { hwLdpVirtualTunnelTable 1 }

        HwLdpVirtualTunnelEntry ::=
            SEQUENCE { 
                hwLdpVirtualTunnelIndex    Unsigned32,
                hwLdpVirtualStatus    INTEGER,
                hwLdpXcIndexArray   OCTET STRING,
                hwLdpOutSegmentIndexArray   OCTET STRING
             }
             
        hwLdpVirtualTunnelIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the LDP virtual tunnel index."
            ::= { hwLdpVirtualTunnelEntry 1 }

        hwLdpVirtualStatus OBJECT-TYPE
            SYNTAX INTEGER
            {
                up(1),     
                down(2),
                testing(3) -- in some test mode
            }
            MAX-ACCESS    read-only
            STATUS         current
            DESCRIPTION
                "The status of this LDP virtual tunnel. 
                 Options:
                 1. up(1)      -indicates that the status of this LDP virtual tunnel is Up.
                 2. down(2)    -indicates that the status of this LDP virtual tunnel is Down.
                 3. testing(3) -indicates that the status of this LDP virtual tunnel is testing, this is, in some test mode.
                 Default: up(1)
                "
            ::= { hwLdpVirtualTunnelEntry 2 }

        hwLdpXcIndexArray OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the xc index of the members of the LDP virtual tunnel."
            ::= { hwLdpVirtualTunnelEntry 3 }

        hwLdpOutSegmentIndexArray OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the outsegment index of the members of the LDP virtual tunnel."
            ::= { hwLdpVirtualTunnelEntry 4 }
            
        hwLdpVirtualTunnelTrap OBJECT IDENTIFIER ::= { hwMplsLsrExtObject 54 }

        hwMplsLdpVirtualTunnelUp NOTIFICATION-TYPE
            OBJECTS { hwLdpVirtualTunnelFEC }
            STATUS current
            DESCRIPTION 
                "A trap is sent when an LDP virtual tunnel goes Up."
            ::= { hwLdpVirtualTunnelTrap 1 }

        hwMplsLdpVirtualTunnelDown NOTIFICATION-TYPE
            OBJECTS { hwLdpVirtualTunnelFEC }
            STATUS current
            DESCRIPTION 
                "A trap is sent when an LDP virtual tunnel goes Down."
            ::= { hwLdpVirtualTunnelTrap 2 }

-- Static LSP Table

         hwMplsStaticLspTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwMplsStaticLspEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table is used to create or delete static LSP configurations.
                 The index of this table is hwMplsStaticLspName.
                "
            ::= { hwMplsLsrExtObject 55 }

        hwMplsStaticLspEntry OBJECT-TYPE
            SYNTAX HwMplsStaticLspEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The entry is used to show or configure static LSP.
                 The index of this entry is hwMplsStaticLspName.
                "
            INDEX {hwMplsStaticLspName }
            ::= { hwMplsStaticLspTable 1 }
        
        HwMplsStaticLspEntry ::=
            SEQUENCE { 
                hwMplsStaticLspName
                    DisplayString,
                hwMplsStaticLspType
                    INTEGER,
                hwMplsStaticLspInIntfIndex
                    Unsigned32,
                hwMplsStaticLspInLabel
                    MplsLabel,
                hwMplsStaticLspLsrId
                    IpAddress,
                hwMplsStaticLspTunnelID
                    Unsigned32,
                hwMplsStaticLspNextHop
                    IpAddress,
                hwMplsStaticLspOutIntfIndex
                    Unsigned32,
                hwMplsStaticLspOutLabel
                    MplsLabel,
                hwMplsStaticLspDestAddr
                    IpAddress,
                hwMplsStaticLspMaskLen
                    Unsigned32,
                hwMplsStaticLspRowStatus
                    RowStatus
             } 

        hwMplsStaticLspName OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This object indicates the name of static LSP."
            ::= { hwMplsStaticLspEntry 1 }

        hwMplsStaticLspType OBJECT-TYPE
            SYNTAX INTEGER 
            {
                ingress(1),
                transit(2),
                egress(3),
                ingressBindTunnel(4)
            }
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object is used to identify the type of static LSP.
                 Options:
                 1. ingress(1)             -indicates that the type of the static LSP is ingress.
                 2. transit(2)             -indicates that the type of the static LSP is transit.
                 3. egress(3)              -indicates that the type of the static LSP is egress.
                 4. ingressBindTunnel(4)   -indicates that the type of the static LSP is ingress-bind-tunnel.
                "
            ::= { hwMplsStaticLspEntry 11 }

        hwMplsStaticLspInIntfIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "This object indicates the incoming-interface index."
            ::= { hwMplsStaticLspEntry 12 }

        hwMplsStaticLspInLabel OBJECT-TYPE
            SYNTAX        MplsLabel
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the in-label."
            ::= { hwMplsStaticLspEntry 13 }
            
        hwMplsStaticLspLsrId OBJECT-TYPE
            SYNTAX        IpAddress
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the LSR ID of ingress static LSP."
            ::= { hwMplsStaticLspEntry 14 }
            
        hwMplsStaticLspTunnelID OBJECT-TYPE
            SYNTAX        Unsigned32
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the Tunnel ID of ingress static LSP." 
            ::= { hwMplsStaticLspEntry 15 }
            
        hwMplsStaticLspNextHop OBJECT-TYPE
            SYNTAX        IpAddress
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the nexthop of static LSP." 
            ::= { hwMplsStaticLspEntry 16 }
            
        hwMplsStaticLspOutIntfIndex OBJECT-TYPE
            SYNTAX        Unsigned32
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the outgoing-interface index."             
            ::= { hwMplsStaticLspEntry 17 }
            
        hwMplsStaticLspOutLabel OBJECT-TYPE
            SYNTAX        MplsLabel
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the out-label."                                 
            ::= { hwMplsStaticLspEntry 18 }
            
        hwMplsStaticLspDestAddr OBJECT-TYPE
            SYNTAX        IpAddress
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the destination."                                     
            ::= { hwMplsStaticLspEntry 19 }

        hwMplsStaticLspMaskLen OBJECT-TYPE
            SYNTAX        Unsigned32
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates the mask length."   
            ::= { hwMplsStaticLspEntry 20 } 
            
        hwMplsStaticLspRowStatus OBJECT-TYPE
            SYNTAX        RowStatus
            MAX-ACCESS    read-create
            STATUS        current
            DESCRIPTION
                "This object indicates whether one entry is created or deleted in hwMplsStaticLspTable. 
                 The value of the object can be CreateAndGo or Destroy. 
                 When the value is set as CreateAndGo, and the entry is created, the status of the object will change into active."                
            ::= { hwMplsStaticLspEntry 51 }

        hwMplsLsrExtConformance OBJECT IDENTIFIER ::= { hwMplsLsrExtMIB 2 }
        
        hwMplsLsrExtCompliances OBJECT IDENTIFIER ::= { hwMplsLsrExtConformance 1 }
        
        hwMplsModuleCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION
                "hwMplsModuleCompliance"
            MODULE HUAWEI-MPLSLSR-EXT-MIB
                MANDATORY-GROUPS { hwMplsBasicGroup, hwMplsInterfaceGroup }
                ::= { hwMplsLsrExtCompliances 1 }
            
            hwMplsLsrExtGroup OBJECT IDENTIFIER ::= { hwMplsLsrExtConformance 2 }
            
            hwMplsBasicGroup OBJECT-GROUP
                OBJECTS { hwMplsLsrId, hwMplsCapabilityConfig, hwMplsLabelAdvertise, hwMplsStatisticsIntervalTimer
                }
                STATUS current
                DESCRIPTION
                    "Objects required for MPLS basic configuration management."
                ::= { hwMplsLsrExtGroup 1 }
            hwMplsBfdGroup OBJECT-GROUP
                OBJECTS { hwMplsBfdCapabilityConfig, hwMplsBfdMinTx, hwMplsBfdMinRx, hwMplsBfdDetectMultiplier, hwMplsFecListName, 
                hwMplsBfdTrigger, hwMplsBfdTriggerNextHop, hwMplsBfdTriggerInterface, hwMplsBfdTriggerFecListName, 
                hwMplsFecListRowStatus }
                STATUS current
                DESCRIPTION
                    "Objects required for MPLS BFD configuration management."
                ::= { hwMplsLsrExtGroup 2 }

            hwLdpStaticFrrGroup OBJECT-GROUP
                OBJECTS { hwLdpStaticFrrNextHop, hwLdpStaticFrrIpPrefix, hwLdpStaticFrrInterfaceRowStatus }
                STATUS current
                DESCRIPTION
                    "Objects required for LDP static FRR configuration management."
                ::= { hwMplsLsrExtGroup 3 }
             
            hwMplsInterfaceGroup OBJECT-GROUP
                OBJECTS { hwMplsMtu, hwMplsInterfaceRowStatus }
                STATUS current
                DESCRIPTION
                    "Objects required for MPLS configuration management on interface."
                ::= { hwMplsLsrExtGroup 4 }
                
            hwMplsLdpVirtualTunnelGroup OBJECT-GROUP
                OBJECTS { hwLdpVirtualTunnelFEC, hwLdpVirtualStatus, hwLdpXcIndexArray, hwLdpOutSegmentIndexArray }
                STATUS current
                DESCRIPTION
                    "Objects required for LDP virtual tunnel management."
                ::= { hwMplsLsrExtGroup 5 }
              
            hwMplsLdpVirtualTunnelNotificationGroup NOTIFICATION-GROUP
                NOTIFICATIONS { hwMplsLdpVirtualTunnelUp, hwMplsLdpVirtualTunnelDown }
                STATUS current
                DESCRIPTION
                    "Notification information about LDP virtual tunnel."
                ::= { hwMplsLsrExtGroup 6 }

            hwMplsStaticLspGroup OBJECT-GROUP
                OBJECTS { hwMplsStaticLspType, hwMplsStaticLspInIntfIndex, hwMplsStaticLspInLabel, hwMplsStaticLspLsrId, hwMplsStaticLspTunnelID, 
                hwMplsStaticLspNextHop, hwMplsStaticLspOutIntfIndex, hwMplsStaticLspOutLabel, hwMplsStaticLspDestAddr, hwMplsStaticLspMaskLen, hwMplsStaticLspRowStatus }
                STATUS current
                DESCRIPTION
                    "Objects required for static LSP configuration management."
                ::= { hwMplsLsrExtGroup 7 }   
     
          hwMplsBgpBfdGroup OBJECT-GROUP
                OBJECTS { hwMplsBgpBfdCapabilityConfig, hwMplsBgpBfdMinTx, hwMplsBgpBfdMinRx, hwMplsBgpBfdDetectMultiplier,
                hwMplsBgpBfdTriggerTunnel, hwMplsBgpBfdTriggerTunnelIpprefix }
                STATUS current
                DESCRIPTION
                    "Objects required for MPLS BGP BFD configuration management."
                ::= { hwMplsLsrExtGroup 8 }     

    END

--
-- HUAWEI-MPLSLSR-EXT-MIB.mib
--