-- Juniper Enterprise Specific MIB: Alarm MIB
-- 
-- Copyright (c) 2001-2003, Juniper Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--

JUNIPER-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Gauge32
        FROM SNMPv2-SMI
    TimeStamp
        FROM SNMPv2-TC
    jnxMibs
        FROM JUNIPER-SMI;

jnxAlarms MODULE-IDENTITY
    LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:46 2003 UTC
    ORGANIZATION "Juniper Networks, Inc."
    CONTACT-INFO
            "        Juniper Technical Assistance Center
                     Juniper Networks, Inc.
                     1133 Innovation Way
                     Sunnyvale, CA 94089
                     E-mail: support@juniper.net"

    DESCRIPTION
            "This is Juniper Networks' implementation of enterprise
         specific MIB for alarms from the router chassis box."
    ::= { jnxMibs 4 }




--  ::= { jnxAlarms 1 }            This OID is obsolete.


--
-- Craft Alarms
--

    jnxCraftAlarms       OBJECT IDENTIFIER ::= { jnxAlarms 2 }


    jnxAlarmRelayMode OBJECT-TYPE
    SYNTAX        INTEGER {
        other(1),    -- other or unknown
        passOn(2),    -- alarms being passed on
        cutOff(3)    -- alarms being cut off
    }        
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The alarm relay mode of the craft interface
        panel for both yellow and red alarms.

        Both yellow and red alarms could be cut off 
        by a front panel Alarm Cutoff / Lamp Test 
        (ACO/LT) button.

        In the pass-on mode, the alarm relay will be 
        activated to pass on the yellow or red alarms.
        In the cut-off mode, both yellow and red alarms
        will be cut off from the alarm relays which are 
        normally connected to audible sirens or visual 
        flashing devices."


    ::= { jnxCraftAlarms 1 }


    jnxYellowAlarms       OBJECT IDENTIFIER ::= { jnxCraftAlarms 2 }

    jnxYellowAlarmState OBJECT-TYPE
    SYNTAX        INTEGER {
            other(1),    -- alarm state is unknown
            off(2),        -- alarm is off
            on(3)        -- alarm is on
    }
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The yellow alarm state on the craft interface 
        panel.

        The yellow alarm is on when there is some 
        system warning such as maintenance alert or 
        significant temperature increase.

        This yellow alarm state could be turned off 
        by the ACO/LT (Alarm Cut Off / Lamp Test) button
        on the front panel module."


    ::= { jnxYellowAlarms 1 }

    jnxYellowAlarmCount OBJECT-TYPE
    SYNTAX        Gauge32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The number of currently active and non-silent 
        yellow alarms.

        This object is independent of the ACO/LT (Alarm
        Cut Off / Lamp Test) button."


    ::= { jnxYellowAlarms 2 }


    jnxYellowAlarmLastChange OBJECT-TYPE
    SYNTAX        TimeStamp
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The value of sysUpTime when the yellow alarm
        last changed - either from off to on or vice
        versa.     Zero if unknown or never changed since
        the agent was up."


    ::= { jnxYellowAlarms 3 }


    jnxRedAlarms       OBJECT IDENTIFIER ::= { jnxCraftAlarms 3 }

    jnxRedAlarmState OBJECT-TYPE
    SYNTAX        INTEGER {
            other(1),    -- alarm state is unknown
            off(2),        -- alarm is off
            on(3)        -- alarm is on
    }
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The red alarm indication on the craft interface 
        panel.

        The red alarm is on when there is some system 
        failure or power supply failure or the system 
        is experiencing a hardware malfunction or some 
        threshold is being exceeded.

        This red alarm state could be turned off by the
        ACO/LT (Alarm Cut Off / Lamp Test) button on the
        front panel module."


    ::= { jnxRedAlarms 1 }


    jnxRedAlarmCount OBJECT-TYPE
    SYNTAX        Gauge32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The number of currently active and non-silent 
        red alarms.

        This object is independent of the ACO/LT (Alarm
        Cut Off / Lamp Test) button."


    ::= { jnxRedAlarms 2 }


    jnxRedAlarmLastChange OBJECT-TYPE
    SYNTAX        TimeStamp
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The value of sysUpTime when the red alarm
        last changed - either from off to on or vice
        versa.     Zero if unknown or never changed since
        the agent was up."


    ::= { jnxRedAlarms 3 }


END