NBS-OTNPM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Integer32, Unsigned32, Counter32, Counter64, OBJECT-TYPE,
    MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE
        FROM SNMPv2-SMI

    TEXTUAL-CONVENTION
        FROM SNMPv2-TC

    ifAlias, InterfaceIndex
        FROM IF-MIB

    nbs, WritableU64
        FROM NBS-MIB;

nbsOtnpmMib  MODULE-IDENTITY
    LAST-UPDATED "201610190000Z" -- October 19, 2016
    ORGANIZATION "NBS"
    CONTACT-INFO
       "For technical support, please contact your service channel"
    DESCRIPTION
       "OTN Performance Monitoring and user-controlled statistics"
    ::= { nbs 222 }

-- *******************************************************************
-- NBS-OTNPM-MIB local defines
-- *******************************************************************

nbsOtnpmThresholdsGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "Maximum considered safe by user"
    ::= { nbsOtnpmMib 1 }

nbsOtnpmCurrentGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "Subtotals and statistics for sample now underway"
    ::= { nbsOtnpmMib 2 }

nbsOtnpmHistoricGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "Totals and final statistics for a previous sample"
    ::= { nbsOtnpmMib 3 }

nbsOtnpmRunningGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "Totals and statistics since (boot-up) protocol configuration"
    ::= { nbsOtnpmMib 4 }

nbsOtnAlarmsGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "OTN alarms"
    ::= { nbsOtnpmMib 80 }

nbsOtnStatsGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "User-controlled OTN alarms and statistics"
    ::= { nbsOtnpmMib 90 }

nbsOtnpmEventsGrp  OBJECT-IDENTITY
    STATUS    current
    DESCRIPTION
       "Threshold crossing events"
    ::= { nbsOtnpmMib 100 }

nbsOtnpmTraps  OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
       "Threshold crossing Traps or Notifications"
    ::= { nbsOtnpmEventsGrp 0 }

-- *******************************************************************

NbsOtnAlarmId  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "OTN alarm id, also used to identify a mask bit"
    SYNTAX      INTEGER {
        aLOS        (1),  -- Loss of Signal
        aLOF        (2),  -- Loss of Frame
        aOOF        (3),  -- Out of Frame
        aLOM        (4),  -- Loss of Multiframe
        aOOM        (5),  -- Out of Multiframe

        aRxLOL      (6),  -- Loss of lock on receive
        aTxLOL      (7),  -- Loss of lock on transmit

        aOtuAIS     (8),  -- Alarm Indication Signal at OTU level
        aSectBDI    (9),  -- Backward Defect Indication (OTU SM)
        aSectBIAE   (10), -- Backward Incoming Alignment Error (OTU SM)
        aSectIAE    (11), -- Incoming Alignment Error (OTU SM)
        aSectTIM    (12), -- Trace Identifier Mismatch (OTU SM)

        aOduAIS     (13), -- Alarm Indication Signal (ODU PM STAT=111)
        aOduOCI     (14), -- Open Connection Indication (ODU PM STAT=110)
        aOduLCK     (15), -- Locked connection (ODU PM STAT=101)
        aPathBDI    (16), -- Backward Defect Indication (ODU PM)
        aPathTIM    (17), -- Trace Identifier Mismatch (ODU PM)

        aTcm1BDI    (18), -- Backward Defect Indication (ODU TCM1)
        aTcm2BDI    (19), -- Backward Defect Indication (ODU TCM2)
        aTcm3BDI    (20), -- Backward Defect Indication (ODU TCM3)
        aTcm4BDI    (21), -- Backward Defect Indication (ODU TCM4)
        aTcm5BDI    (22), -- Backward Defect Indication (ODU TCM5)
        aTcm6BDI    (23), -- Backward Defect Indication (ODU TCM6)

        aTcm1BIAE   (24), -- Backward Incoming Alignment Error (ODU TCM1)
        aTcm2BIAE   (25), -- Backward Incoming Alignment Error (ODU TCM2)
        aTcm3BIAE   (26), -- Backward Incoming Alignment Error (ODU TCM3)
        aTcm4BIAE   (27), -- Backward Incoming Alignment Error (ODU TCM4)
        aTcm5BIAE   (28), -- Backward Incoming Alignment Error (ODU TCM5)
        aTcm6BIAE   (29), -- Backward Incoming Alignment Error (ODU TCM6)

        aTcm1IAE    (30), -- Incoming Alignment Error (ODU TCM1 STAT=010)
        aTcm2IAE    (31), -- Incoming Alignment Error (ODU TCM2 STAT=010)
        aTcm3IAE    (32), -- Incoming Alignment Error (ODU TCM3 STAT=010)
        aTcm4IAE    (33), -- Incoming Alignment Error (ODU TCM4 STAT=010)
        aTcm5IAE    (34), -- Incoming Alignment Error (ODU TCM5 STAT=010)
        aTcm6IAE    (35), -- Incoming Alignment Error (ODU TCM6 STAT=010)

        aTcm1LTC    (36), -- Loss of Tandem Connection (ODU TCM1 STAT=000)
        aTcm2LTC    (37), -- Loss of Tandem Connection (ODU TCM2 STAT=000)
        aTcm3LTC    (38), -- Loss of Tandem Connection (ODU TCM3 STAT=000)
        aTcm4LTC    (39), -- Loss of Tandem Connection (ODU TCM4 STAT=000)
        aTcm5LTC    (40), -- Loss of Tandem Connection (ODU TCM5 STAT=000)
        aTcm6LTC    (41), -- Loss of Tandem Connection (ODU TCM6 STAT=000)

        aTcm1TIM    (42), -- Trace Identifier Mismatch (ODU TCM1)
        aTcm2TIM    (43), -- Trace Identifier Mismatch (ODU TCM2)
        aTcm3TIM    (44), -- Trace Identifier Mismatch (ODU TCM3)
        aTcm4TIM    (45), -- Trace Identifier Mismatch (ODU TCM4)
        aTcm5TIM    (46), -- Trace Identifier Mismatch (ODU TCM5)
        aTcm6TIM    (47), -- Trace Identifier Mismatch (ODU TCM6)

        aFwdSF      (48), -- Forward Signal Fail (ODU FTFL)
        aFwdSD      (49), -- Forward Signal Degrade (ODU FTFL)
        aBwdSF      (50), -- Backward Signal Fail (ODU FTFL)
        aBwdSD      (51), -- Backward Signal Degrade (ODU FTFL)

        aPTM        (52), -- Payload Type Mismatch (OPU PSI)
        aCSF        (53)  -- Client Signal Fail (OPU PSI)
    }

NbsOtnAlarmMask  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "OTN alarm mask, encoded within an octet string. The bit assigned
        to a particular alarm (id from NbsOtnAlarmId) is calculated by:
            index = id/8; bit = id%8;
        where the leftmost bit (msb) is deemed as bit 0.
        The mask length is either full-size or zero if not supported."
    SYNTAX      OCTET STRING (SIZE(0..7))


-- *******************************************************************
--
-- the nbsOtnpmThresholdsGrp
--
-- *******************************************************************

nbsOtnpmThresholdsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnpmThresholdsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN Performance Monitoring thresholds"
    ::= { nbsOtnpmThresholdsGrp 1 }

nbsOtnpmThresholdsEntry OBJECT-TYPE
    SYNTAX          NbsOtnpmThresholdsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "Performance monitoring thresholds for a particular interface"
    INDEX {
        nbsOtnpmThresholdsIfIndex,
        nbsOtnpmThresholdsInterval,
        nbsOtnpmThresholdsScope
    }
    ::= { nbsOtnpmThresholdsTable 1 }

NbsOtnpmThresholdsEntry ::= SEQUENCE {
    nbsOtnpmThresholdsIfIndex    InterfaceIndex,
    nbsOtnpmThresholdsInterval   INTEGER,
    nbsOtnpmThresholdsScope      INTEGER,
    nbsOtnpmThresholdsEs         Unsigned32,
    nbsOtnpmThresholdsEsrSig     INTEGER,
    nbsOtnpmThresholdsEsrExp     Integer32,
    nbsOtnpmThresholdsSes        Unsigned32,
    nbsOtnpmThresholdsSesrSig    INTEGER,
    nbsOtnpmThresholdsSesrExp    Integer32,
    nbsOtnpmThresholdsBbe        WritableU64,
    nbsOtnpmThresholdsBberSig    INTEGER,
    nbsOtnpmThresholdsBberExp    Integer32,
    nbsOtnpmThresholdsUas        Unsigned32,
    nbsOtnpmThresholdsFc         WritableU64
}

nbsOtnpmThresholdsIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnpmThresholdsEntry 1 }

nbsOtnpmThresholdsInterval OBJECT-TYPE
    SYNTAX          INTEGER {
        quarterHour    (1),
        twentyfourHour (2)
    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "Indicates the sampling period to which these thresholds apply"
    ::= { nbsOtnpmThresholdsEntry 2 }

nbsOtnpmThresholdsScope OBJECT-TYPE
    SYNTAX          INTEGER {
        tcm1    (1),
        tcm2    (2),
        tcm3    (3),
        tcm4    (4),
        tcm5    (5),
        tcm6    (6),
        section (7),
        path    (8)
    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "This object specifies the network segment to which these
        thresholds apply."
    ::= { nbsOtnpmThresholdsEntry 3 }

nbsOtnpmThresholdsEs OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The number of Errored Seconds (ES) which, if met
        or exceeded at the end of the nbsOtnpmThresholdsInterval
        period, should trigger the nbsOtnpmTrapsEs event notification.

        The reserved value 0 disables notifications for this event."
--  DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 10 }

nbsOtnpmThresholdsEsrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The significand of the Errored Seconds Ratio (ESR)
        threshold, which is calculated by:
           nbsOtnpmThresholdsEsrSig x 10^nbsOtnpmThresholdsEsrExp

        An ESR that meets or exceeds this threshold at the end of the
        nbsOtnpmThresholdsInterval period triggers the nbsOtnpmTrapsEsr
        event notification.

        The reserved value 0 disables notifications for this event."
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 11 }

nbsOtnpmThresholdsEsrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The exponent of the Errored Seconds Ratio (ESR)
        threshold; see nbsOtnpmThresholdsEsrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 12 }

nbsOtnpmThresholdsSes  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The number of Severely Errored Seconds (SES)
        which, if met or exceeded at the end of the
        nbsOtnpmThresholdsInterval period, should trigger the
        nbsOtnpmTrapsSes event notification.

        The reserved value 0 disables notifications for this event."
--  DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 13 }

nbsOtnpmThresholdsSesrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The significand of the Severely Errored Seconds
        Ratio (SESR) threshold, which is calculated by:
           nbsOtnpmThresholdsSesrSig x 10^nbsOtnpmThresholdsSesrExp

        A SESR that meets or exceeds this threshold at the end of the
        nbsOtnpmThresholdsInterval period triggers the nbsOtnpmTrapsSesr
        notification.

        The reserved value 0 disables notifications for this event."
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 14 }

nbsOtnpmThresholdsSesrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The exponent of the Severely Errored Seconds
        Ratio (SESR) threshold; see nbsOtnpmThresholdsSesrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 15 }

nbsOtnpmThresholdsBbe   OBJECT-TYPE
    SYNTAX          WritableU64
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The number of Background Block Errors (BBE) which,
        if met or exceeded at the end of the nbsOtnpmThresholdsInterval
        period, should trigger the nbsOtnpmTrapsBbe event notification.

        The reserved value 0 disables notifications for this event."
--  DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 16 }

nbsOtnpmThresholdsBberSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The significand of the Background Block Errors
        Ratio (BBER) threshold, which is calculated by:
           nbsOtnpmThresholdsBberSig x 10^nbsOtnpmThresholdsBberExp

        A BBER that meets or exceeds this threshold at the end of the
        nbsOtnpmThresholdsInterval period triggers the nbsOtnpmTrapsBber
        notification.

        The reserved value 0 disables notifications for this event."
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 17 }

nbsOtnpmThresholdsBberExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The exponent of the Background Block Errors
        Ratio (BBER) threshold; see nbsOtnpmThresholdsBberSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 18 }

nbsOtnpmThresholdsUas  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The number of Unavailable Seconds (UAS) which,
        if met or exceeded at the end of the nbsOtnpmThresholdsInterval
        period, should trigger the nbsOtnpmTrapsUas event notification.

        The reserved value 0 disables notifications for this event."
--  DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 19 }

nbsOtnpmThresholdsFc   OBJECT-TYPE
    SYNTAX          WritableU64
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
       "Persistent.  The number of Failure Counts (FC) which, if met or
        exceeded at the end of the nbsOtnpmThresholdsInterval period,
        should trigger the nbsOtnpmTrapsFc event notification.

        The reserved value 0 disables notifications for this event."
--  DEFVAL { 0 }
    ::= { nbsOtnpmThresholdsEntry 20 }


-- *******************************************************************
--
-- the nbsOtnpmCurrentGroup
--
-- *******************************************************************

nbsOtnpmCurrentTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnpmCurrentEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "All OTN Performance Monitoring statistics for the
        nbsOtnpmCurrentInterval now underway."
    ::= { nbsOtnpmCurrentGrp 3 }

nbsOtnpmCurrentEntry OBJECT-TYPE
    SYNTAX          NbsOtnpmCurrentEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN Performance Monitoring statistics for a specific port/
        interface and nbsOtnpmCurrentInterval."
    INDEX {
        nbsOtnpmCurrentIfIndex,
        nbsOtnpmCurrentInterval,
        nbsOtnpmCurrentScope
    }
    ::= { nbsOtnpmCurrentTable 1 }

NbsOtnpmCurrentEntry ::= SEQUENCE {
    nbsOtnpmCurrentIfIndex          InterfaceIndex,
    nbsOtnpmCurrentInterval         INTEGER,
    nbsOtnpmCurrentScope            INTEGER,
    nbsOtnpmCurrentDate             INTEGER,
    nbsOtnpmCurrentTime             INTEGER,
    nbsOtnpmCurrentEs               Unsigned32,
    nbsOtnpmCurrentEsrSig           INTEGER,
    nbsOtnpmCurrentEsrExp           Integer32,
    nbsOtnpmCurrentSes              Unsigned32,
    nbsOtnpmCurrentSesrSig          INTEGER,
    nbsOtnpmCurrentSesrExp          Integer32,
    nbsOtnpmCurrentBbe              Counter64,
    nbsOtnpmCurrentBberSig          INTEGER,
    nbsOtnpmCurrentBberExp          Integer32,
    nbsOtnpmCurrentUas              Unsigned32,
    nbsOtnpmCurrentFc               Counter64,
    nbsOtnpmCurrentAlarmsSupported  NbsOtnAlarmMask,
    nbsOtnpmCurrentAlarmsRaised     NbsOtnAlarmMask,
    nbsOtnpmCurrentAlarmsChanged    NbsOtnAlarmMask
}

nbsOtnpmCurrentIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnpmCurrentEntry 1 }

nbsOtnpmCurrentInterval OBJECT-TYPE
    SYNTAX          INTEGER {
        quarterHour    (1),
        twentyfourHour (2)
    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "Indicates the sampling period of statistic"
    ::= { nbsOtnpmCurrentEntry 2 }

nbsOtnpmCurrentScope OBJECT-TYPE
    SYNTAX          INTEGER {
        tcm1    (1),
        tcm2    (2),
        tcm3    (3),
        tcm4    (4),
        tcm5    (5),
        tcm6    (6),
        section (7),
        path    (8)
    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "Indicates statistic's network segment"
    ::= { nbsOtnpmCurrentEntry 3 }

nbsOtnpmCurrentDate OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The date (UTC) this interval began, represented by an eight
        digit decimal number: yyyymmdd"
    ::= { nbsOtnpmCurrentEntry 5 }

nbsOtnpmCurrentTime OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The time (UTC) this interval began, represented by a six
        digit decimal number: hhmmss"
    ::= { nbsOtnpmCurrentEntry 6 }

nbsOtnpmCurrentEs OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Errored Seconds (ES) in this interval so far."
--  DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 10 }

nbsOtnpmCurrentEsrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the current Errored Seconds Ratio (ESR),
        which is calculated by:
           nbsOtnpmCurrentEsrSig x 10^nbsOtnpmCurrentEsrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 11 }

nbsOtnpmCurrentEsrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the current Errored Seconds Ratio (ESR);
        see nbsOtnpmCurrentEsrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 12 }

nbsOtnpmCurrentSes  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Severely Errored Seconds (SES) in this interval
        so far"
--  DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 13 }

nbsOtnpmCurrentSesrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the current Severely Errored Seconds
        Ratio (SESR), which is calculated by:
           nbsOtnpmCurrentSesrSig x 10^nbsOtnpmCurrentSesrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 14 }

nbsOtnpmCurrentSesrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the current Severely Errored Seconds
        Ratio (SESR); see nbsOtnpmCurrentSesrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 15 }

nbsOtnpmCurrentBbe   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Background Block Errors (BBE) so far,
        i.e. the count of Bit Interleave Parity (BIP8) errors."
--  DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 16 }

nbsOtnpmCurrentBberSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the current Background Block Errors (BBER),
        which is calculated by:
           nbsOtnpmCurrentBberSig x 10^nbsOtnpmCurrentBberExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 17 }

nbsOtnpmCurrentBberExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the current Background Block Errors Ratio (BBER);
        see nbsOtnpmCurrentBberSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 18 }

nbsOtnpmCurrentUas  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Unavailable Seconds (UAS) so far"
--  DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 19 }

nbsOtnpmCurrentFc   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Failure Counts (FC) so far, i.e. the count of
        Backward Error Indication (BEI) errors."
--  DEFVAL { 0 }
    ::= { nbsOtnpmCurrentEntry 20 }

nbsOtnpmCurrentAlarmsSupported OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are supported."
    ::= { nbsOtnpmCurrentEntry 100 }

nbsOtnpmCurrentAlarmsRaised OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are currently raised."
    ::= { nbsOtnpmCurrentEntry 101 }

nbsOtnpmCurrentAlarmsChanged OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that have changed so far, i.e. alarms that
        have transitioned at least once from clear to raised or from
        raised to clear."
    ::= { nbsOtnpmCurrentEntry 102 }


-- *******************************************************************
--
-- the nbsOtnpmHistoricGrp
--
-- *******************************************************************

nbsOtnpmHistoricTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnpmHistoricEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "All OTN Performance Monitoring statistics for past
        nbsOtnpmHistoricInterval periods."
    ::= { nbsOtnpmHistoricGrp 3 }

nbsOtnpmHistoricEntry OBJECT-TYPE
    SYNTAX          NbsOtnpmHistoricEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN Performance Monitoring statistics for a specific port/
        interface and nbsOtnpmHistoricInterval."
    INDEX {
        nbsOtnpmHistoricIfIndex,
        nbsOtnpmHistoricInterval,
        nbsOtnpmHistoricScope,
        nbsOtnpmHistoricSample
    }
    ::= { nbsOtnpmHistoricTable 1 }

NbsOtnpmHistoricEntry ::= SEQUENCE {
    nbsOtnpmHistoricIfIndex         InterfaceIndex,
    nbsOtnpmHistoricInterval        INTEGER,
    nbsOtnpmHistoricScope           INTEGER,
    nbsOtnpmHistoricSample          INTEGER,
    nbsOtnpmHistoricDate            INTEGER,
    nbsOtnpmHistoricTime            INTEGER,
    nbsOtnpmHistoricEs              Unsigned32,
    nbsOtnpmHistoricEsrSig          INTEGER,
    nbsOtnpmHistoricEsrExp          Integer32,
    nbsOtnpmHistoricSes             Unsigned32,
    nbsOtnpmHistoricSesrSig         INTEGER,
    nbsOtnpmHistoricSesrExp         Integer32,
    nbsOtnpmHistoricBbe             Counter64,
    nbsOtnpmHistoricBberSig         INTEGER,
    nbsOtnpmHistoricBberExp         Integer32,
    nbsOtnpmHistoricUas             Unsigned32,
    nbsOtnpmHistoricFc              Counter64,
    nbsOtnpmHistoricAlarmsSupported NbsOtnAlarmMask,
    nbsOtnpmHistoricAlarmsRaised    NbsOtnAlarmMask,
    nbsOtnpmHistoricAlarmsChanged   NbsOtnAlarmMask
}

nbsOtnpmHistoricIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnpmHistoricEntry 1 }

nbsOtnpmHistoricInterval OBJECT-TYPE
    SYNTAX          INTEGER {
        quarterHour    (1),
        twentyfourHour (2)
    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "Indicates the sampling period of statistic"
    ::= { nbsOtnpmHistoricEntry 2 }

nbsOtnpmHistoricScope OBJECT-TYPE
    SYNTAX          INTEGER {
        tcm1    (1),
        tcm2    (2),
        tcm3    (3),
        tcm4    (4),
        tcm5    (5),
        tcm6    (6),
        section (7),
        path    (8)
    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "Indicates statistic's network segment"
    ::= { nbsOtnpmHistoricEntry 3 }

nbsOtnpmHistoricSample OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "Indicates the sample number of this statistic.  The most
        recent sample is numbered 1, the next previous 2, and so on
        until the oldest sample."
    ::= { nbsOtnpmHistoricEntry 4 }

nbsOtnpmHistoricDate OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The date (UTC) the interval began, represented by an eight
        digit decimal number: yyyymmdd"
    ::= { nbsOtnpmHistoricEntry 5 }

nbsOtnpmHistoricTime OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The time (UTC) the interval began, represented by a six
        digit decimal number: hhmmss"
    ::= { nbsOtnpmHistoricEntry 6 }

nbsOtnpmHistoricEs OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The final count of Errored Seconds (ES) for this interval"
--  DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 10 }

nbsOtnpmHistoricEsrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the final Errored Seconds Ratio (ESR)
        for this interval, which is calculated by:
           nbsOtnpmHistoricEsrSig x 10^nbsOtnpmHistoricEsrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 11 }

nbsOtnpmHistoricEsrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the final Errored Seconds Ratio (ESR)
        for this interval; see nbsOtnpmHistoricEsrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 12 }

nbsOtnpmHistoricSes  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The final count of Severely Errored Seconds (SES) in this interval"
--  DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 13 }

nbsOtnpmHistoricSesrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the final Severely Errored Seconds
        Ratio (SESR) for this interval, which is calculated by:
           nbsOtnpmHistoricSesrSig x 10^nbsOtnpmHistoricSesrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 14 }

nbsOtnpmHistoricSesrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the final Severely Errored Seconds
        Ratio (SESR) for this interval; see nbsOtnpmHistoricSesrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 15 }

nbsOtnpmHistoricBbe   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The final count of Background Block Errors (BBE),
        i.e. the count of Bit Interleave Parity (BIP8) errors."
--  DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 16 }

nbsOtnpmHistoricBberSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the final Background Block Errors
        Ratio (BBER) for this interval, which is calculated by:
        nbsOtnpmHistoricBberSig x 10^nbsOtnpmHistoricBberExp)"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 17 }

nbsOtnpmHistoricBberExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the final Background Block Errors
        Ratio (BBER) for this interval; see nbsOtnpmHistoricBberSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 18 }

nbsOtnpmHistoricUas  OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The final count of Unavailable Seconds (UAS)"
--  DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 19 }

nbsOtnpmHistoricFc   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The final number of Failure Counts (FC), i.e. the count of
        Backward Error Indication (BEI) errors."
--  DEFVAL { 0 }
    ::= { nbsOtnpmHistoricEntry 20 }

nbsOtnpmHistoricAlarmsSupported OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that were supported."
    ::= { nbsOtnpmHistoricEntry 100 }

nbsOtnpmHistoricAlarmsRaised OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that were raised at the end of this interval."
    ::= { nbsOtnpmHistoricEntry 101 }

nbsOtnpmHistoricAlarmsChanged OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that changed in this interval, i.e. alarms
        that transitioned at least once from clear to raised or from
        raised to clear."
    ::= { nbsOtnpmHistoricEntry 102 }


-- *******************************************************************
--
-- the nbsOtnpmRunningGroup
--
-- *******************************************************************

nbsOtnpmRunningTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnpmRunningEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "All OTN Performance Monitoring statistics since (boot-up) protocol
        configuration."
    ::= { nbsOtnpmRunningGrp 3 }

nbsOtnpmRunningEntry OBJECT-TYPE
    SYNTAX          NbsOtnpmRunningEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN Performance Monitoring statistics for a specific port/
        interface."
    INDEX {
        nbsOtnpmRunningIfIndex,
        nbsOtnpmRunningScope
    }
    ::= { nbsOtnpmRunningTable 1 }

NbsOtnpmRunningEntry ::= SEQUENCE {
    nbsOtnpmRunningIfIndex          InterfaceIndex,
    nbsOtnpmRunningScope            INTEGER,
    nbsOtnpmRunningDate             INTEGER,
    nbsOtnpmRunningTime             INTEGER,
    nbsOtnpmRunningEs               Counter32,
    nbsOtnpmRunningEsrSig           INTEGER,
    nbsOtnpmRunningEsrExp           Integer32,
    nbsOtnpmRunningSes              Counter32,
    nbsOtnpmRunningSesrSig          INTEGER,
    nbsOtnpmRunningSesrExp          Integer32,
    nbsOtnpmRunningBbe              Counter64,
    nbsOtnpmRunningBberSig          INTEGER,
    nbsOtnpmRunningBberExp          Integer32,
    nbsOtnpmRunningUas              Counter32,
    nbsOtnpmRunningFc               Counter64,
    nbsOtnpmRunningAlarmsSupported  NbsOtnAlarmMask,
    nbsOtnpmRunningAlarmsRaised     NbsOtnAlarmMask,
    nbsOtnpmRunningAlarmsChanged    NbsOtnAlarmMask
}

nbsOtnpmRunningIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnpmRunningEntry 1 }

nbsOtnpmRunningScope OBJECT-TYPE
    SYNTAX          INTEGER {
        tcm1    (1),
        tcm2    (2),
        tcm3    (3),
        tcm4    (4),
        tcm5    (5),
        tcm6    (6),
        section (7),
        path    (8)
    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "Indicates statistic's network segment"
    ::= { nbsOtnpmRunningEntry 3 }

nbsOtnpmRunningDate OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The date (UTC) of protocol configuration, represented by an
        eight digit decimal number: yyyymmdd"
    ::= { nbsOtnpmRunningEntry 5 }

nbsOtnpmRunningTime OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The time (UTC) of protocol configuration, represented by a
        six digit decimal number: hhmmss"
    ::= { nbsOtnpmRunningEntry 6 }

nbsOtnpmRunningEs OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Errored Seconds (ES) since protocol configuration."
    ::= { nbsOtnpmRunningEntry 10 }

nbsOtnpmRunningEsrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the running Errored Seconds Ratio (ESR),
        which is calculated by:
           nbsOtnpmRunningEsrSig x 10^nbsOtnpmRunningEsrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 11 }

nbsOtnpmRunningEsrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the running Errored Seconds Ratio (ESR);
        see nbsOtnpmRunningEsrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 12 }

nbsOtnpmRunningSes  OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Severely Errored Seconds (SES) since protocol configuration"
    ::= { nbsOtnpmRunningEntry 13 }

nbsOtnpmRunningSesrSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the running Severely Errored Seconds
        Ratio (SESR), which is calculated by:
           nbsOtnpmRunningSesrSig x 10^nbsOtnpmRunningSesrExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 14 }

nbsOtnpmRunningSesrExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the running Severely Errored Seconds
        Ratio (SESR); see nbsOtnpmRunningSesrSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 15 }

nbsOtnpmRunningBbe   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Background Block Errors (BBE) since protocol configuration,
        i.e. the count of Bit Interleave Parity (BIP8) errors."
    ::= { nbsOtnpmRunningEntry 16 }

nbsOtnpmRunningBberSig OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The significand of the running Background Block Errors (BBER),
        which is calculated by:
           nbsOtnpmRunningBberSig x 10^nbsOtnpmRunningBberExp"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 17 }

nbsOtnpmRunningBberExp OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The exponent of the running Background Block Errors Ratio (BBER);
        see nbsOtnpmRunningBberSig.

        Not supported value: 0x80000000"
    DEFVAL { 0 }
    ::= { nbsOtnpmRunningEntry 18 }

nbsOtnpmRunningUas  OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Unavailable Seconds (UAS) since protocol configuration"
    ::= { nbsOtnpmRunningEntry 19 }

nbsOtnpmRunningFc   OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The number of Failure Counts (FC) since protocol configuration,
        i.e. the count of Backward Error Indication (BEI) errors."
    ::= { nbsOtnpmRunningEntry 20 }

nbsOtnpmRunningAlarmsSupported OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are supported."
    ::= { nbsOtnpmRunningEntry 100 }

nbsOtnpmRunningAlarmsRaised OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are currently raised."
    ::= { nbsOtnpmRunningEntry 101 }

nbsOtnpmRunningAlarmsChanged OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that changed since protocol configuration,
        i.e. alarms that transitioned at least once from clear to raised or
        from raised to clear."
    ::= { nbsOtnpmRunningEntry 102 }


-- *******************************************************************
--
-- the nbsOtnAlarmsGroup
--
-- *******************************************************************

nbsOtnAlarmsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnAlarmsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN alarm monitoring scoreboard, showing for each possible alarm
        if it is currently raised and if it has changed since monitoring
        began (or was cleared). The latter indicator may be cleared at
        anytime without affecting normal performance monitoring activity."
    ::= { nbsOtnAlarmsGrp 3 }

nbsOtnAlarmsEntry OBJECT-TYPE
    SYNTAX          NbsOtnAlarmsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN alarm monitoring scoreboard for a specific port/interface."
    INDEX {
        nbsOtnAlarmsIfIndex
    }
    ::= { nbsOtnAlarmsTable 1 }

NbsOtnAlarmsEntry ::= SEQUENCE {
    nbsOtnAlarmsIfIndex         InterfaceIndex,
    nbsOtnAlarmsDate            INTEGER,
    nbsOtnAlarmsTime            INTEGER,
    nbsOtnAlarmsSpan            INTEGER,
    nbsOtnAlarmsState           INTEGER,
    nbsOtnAlarmsSupported       NbsOtnAlarmMask,
    nbsOtnAlarmsRaised          NbsOtnAlarmMask,
    nbsOtnAlarmsChanged         NbsOtnAlarmMask,
    nbsOtnAlarmsRcvdFTFL        OCTET STRING
}

nbsOtnAlarmsIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnAlarmsEntry 1 }

nbsOtnAlarmsDate OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The date (UTC) OTN alarm monitoring began (was cleared), represented
        by an eight digit decimal number: yyyymmdd"
    ::= { nbsOtnAlarmsEntry 5 }

nbsOtnAlarmsTime OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The time (UTC) OTN alarm monitoring began (was cleared), represented
        by a six digit decimal number: hhmmss"
    ::= { nbsOtnAlarmsEntry 6 }

nbsOtnAlarmsSpan OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The amount of time (deci-sec) since nbsOtnAlarmsDate and
        nbsOtnAlarmsTime."
    ::= { nbsOtnAlarmsEntry 7 }

nbsOtnAlarmsState OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported (1),
        monitoring   (2),
        clearing     (3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "This object reads 'notSupported' if the port is not configured with
        an OTN protocol. Otherwise it reads 'monitoring' to indicate that
        supported OTN alarms are actively reported in nbsOtnAlarmsRaised
        and nbsOtnAlarmsChanged.

        Writing 'clearing' to this object clears nbsOtnAlarmsChanged."
    ::= { nbsOtnAlarmsEntry 8 }

nbsOtnAlarmsSupported OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are supported on this port."
    ::= { nbsOtnAlarmsEntry 100 }

nbsOtnAlarmsRaised OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are currently raised."
    ::= { nbsOtnAlarmsEntry 101 }

nbsOtnAlarmsChanged OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that have changed since nbsOtnAlarmsDate and
        AlarmsTime, i.e. alarms that have transitioned at least once from
        clear to raised or from raised to clear."
    ::= { nbsOtnAlarmsEntry 102 }

nbsOtnAlarmsRcvdFTFL OBJECT-TYPE
    SYNTAX      OCTET STRING(SIZE(0..256))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The current Fault Type Fault Location information received on the
        given port. The length will be zero when there is a no fault code
        in both the forward and backward fields. Otherwise, the full 256
        bytes will be provided; see ITU-T G.709, section 15.8.2.5."
    ::= { nbsOtnAlarmsEntry 110 }


-- *******************************************************************
--
-- the nbsOtnStatsGroup
--
-- *******************************************************************

nbsOtnStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF NbsOtnStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "OTN alarms and statistics monitoring managed per user discretion.
        This monitoring may be started, stopped, and cleared as desired
        without affecting the normal performance monitoring activity."
    ::= { nbsOtnStatsGrp 3 }

nbsOtnStatsEntry OBJECT-TYPE
    SYNTAX          NbsOtnStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
       "User-controlled OTN monitoring for a specific port/interface."
    INDEX {
        nbsOtnStatsIfIndex
    }
    ::= { nbsOtnStatsTable 1 }

NbsOtnStatsEntry ::= SEQUENCE {
    nbsOtnStatsIfIndex          InterfaceIndex,
    nbsOtnStatsDate             INTEGER,
    nbsOtnStatsTime             INTEGER,
    nbsOtnStatsSpan             INTEGER,
    nbsOtnStatsState            INTEGER,
    nbsOtnStatsErrCntSectBEI    Counter64,
    nbsOtnStatsErrCntPathBEI    Counter64,
    nbsOtnStatsErrCntTcm1BEI    Counter64,
    nbsOtnStatsErrCntTcm2BEI    Counter64,
    nbsOtnStatsErrCntTcm3BEI    Counter64,
    nbsOtnStatsErrCntTcm4BEI    Counter64,
    nbsOtnStatsErrCntTcm5BEI    Counter64,
    nbsOtnStatsErrCntTcm6BEI    Counter64,
    nbsOtnStatsErrCntSectBIP8   Counter64,
    nbsOtnStatsErrCntPathBIP8   Counter64,
    nbsOtnStatsErrCntTcm1BIP8   Counter64,
    nbsOtnStatsErrCntTcm2BIP8   Counter64,
    nbsOtnStatsErrCntTcm3BIP8   Counter64,
    nbsOtnStatsErrCntTcm4BIP8   Counter64,
    nbsOtnStatsErrCntTcm5BIP8   Counter64,
    nbsOtnStatsErrCntTcm6BIP8   Counter64,
    nbsOtnStatsAlarmsSupported  NbsOtnAlarmMask,
    nbsOtnStatsAlarmsRaised     NbsOtnAlarmMask,
    nbsOtnStatsAlarmsChanged    NbsOtnAlarmMask
}

nbsOtnStatsIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The mib2 ifIndex"
    ::= { nbsOtnStatsEntry 1 }

nbsOtnStatsDate OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The date (UTC) OTN statistics collection began, represented by an
        eight digit decimal number: yyyymmdd"
    ::= { nbsOtnStatsEntry 5 }

nbsOtnStatsTime OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The time (UTC) OTN statistics collection began, represented by a
        six digit decimal number: hhmmss"
    ::= { nbsOtnStatsEntry 6 }

nbsOtnStatsSpan OBJECT-TYPE
    SYNTAX          INTEGER
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The amount of time (deci-sec) statistics collection has been underway
        since nbsOtnStatsDate and nbsOtnStatsTime, or if stopped, the duration
        of the prior collection."
    ::= { nbsOtnStatsEntry 7 }

nbsOtnStatsState OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported (1),
        counting     (2),
        clearing     (3),
        stopped      (4)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "Writing 'stopped' to this object stops (pauses) OTN statistics
        collection. Re-configuring this port to a non-OTN protocol sets
        this object to 'stopped' automatically.

        Writing 'counting' to this object starts (resumes) OTN statistics
        collection if this port is configured with an OTN protocol.

        Writing 'clearing' to this object clears all statistical counters."
    ::= { nbsOtnStatsEntry 8 }

nbsOtnStatsErrCntSectBEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of section Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 21 }

nbsOtnStatsErrCntPathBEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of path Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 22 }

nbsOtnStatsErrCntTcm1BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM1 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 23 }

nbsOtnStatsErrCntTcm2BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM2 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 24 }

nbsOtnStatsErrCntTcm3BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM3 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 25 }

nbsOtnStatsErrCntTcm4BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM4 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 26 }

nbsOtnStatsErrCntTcm5BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM5 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 27 }

nbsOtnStatsErrCntTcm6BEI OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM6 Backward Error Indication errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 28 }

nbsOtnStatsErrCntSectBIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of section Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 31 }

nbsOtnStatsErrCntPathBIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of path Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 32 }

nbsOtnStatsErrCntTcm1BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM1 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 33 }

nbsOtnStatsErrCntTcm2BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM2 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 34 }

nbsOtnStatsErrCntTcm3BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM3 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 35 }

nbsOtnStatsErrCntTcm4BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM4 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 36 }

nbsOtnStatsErrCntTcm5BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM5 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 37 }

nbsOtnStatsErrCntTcm6BIP8 OBJECT-TYPE
    SYNTAX          Counter64
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
       "The count of TCM6 Bit Interleave Parity errors detected since
        OTN statistics collection began."
    ::= { nbsOtnStatsEntry 38 }

nbsOtnStatsAlarmsSupported OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are supported."
    ::= { nbsOtnStatsEntry 100 }

nbsOtnStatsAlarmsRaised OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that are currently raised."
    ::= { nbsOtnStatsEntry 101 }

nbsOtnStatsAlarmsChanged OBJECT-TYPE
    SYNTAX      NbsOtnAlarmMask
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The mask of OTN alarms that have changed since OTN statistics
        collection began, i.e. alarms that have transitioned at least
        once from clear to raised or from raised to clear."
    ::= { nbsOtnStatsEntry 102 }


-- *******************************************************************
--
-- the nbsOtnpmEventsGrp
--
-- *******************************************************************

nbsOtnpmTrapsEs  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentEs }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsEs is non-zero and less than or equal to
        nbsOtnpmCurrentEs."
    ::= { nbsOtnpmTraps 10 }

nbsOtnpmTrapsEsr  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentEsrSig, nbsOtnpmCurrentEsrExp }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsEsr is non-zero and less than or equal to
        nbsOtnpmCurrentEsr."
    ::= { nbsOtnpmTraps 11 }

nbsOtnpmTrapsSes  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentSes }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsSes is non-zero and less than or equal to
        nbsOtnpmCurrentSes."
    ::= { nbsOtnpmTraps 12 }

nbsOtnpmTrapsSesr  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentSesrSig, nbsOtnpmCurrentSesrExp }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsSesr is non-zero and less than or equal to
        nbsOtnpmCurrentSesr."
    ::= { nbsOtnpmTraps 13 }

nbsOtnpmTrapsBbe  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentBbe }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsBbe is non-zero and less than or equal to
        nbsOtnpmCurrentBbe."
    ::= { nbsOtnpmTraps 14 }

nbsOtnpmTrapsBber  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentBberSig, nbsOtnpmCurrentBberExp}
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsBber is non-zero and less than or equal to
        nbsOtnpmCurrentBber."
    ::= { nbsOtnpmTraps 15 }

nbsOtnpmTrapsUas  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentUas }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsUas is non-zero and less than or equal to
        nbsOtnpmCurrentUas."
    ::= { nbsOtnpmTraps 16 }

nbsOtnpmTrapsFc  NOTIFICATION-TYPE
    OBJECTS   { nbsOtnpmCurrentIfIndex, ifAlias,
                nbsOtnpmCurrentInterval, nbsOtnpmCurrentScope,
                nbsOtnpmCurrentFc }
    STATUS      current
    DESCRIPTION
       "Sent at the conclusion of an nbsOtnpmThresholdsInterval if
        nbsOtnpmThresholdsFc is non-zero and less than or equal to
        nbsOtnpmCurrentFc."
    ::= { nbsOtnpmTraps 17 }


END