librenms/librenms

View on GitHub
mibs/mrv/NBS-SFF-MIB

Summary

Maintainability
Test Coverage
NBS-SFF-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    InterfaceIndex
        FROM IF-MIB
    NbsCmmcChannelBand
        FROM NBS-CMMCENUM-MIB
    nbs, NbsTcMHz
        FROM NBS-MIB;

nbsSffMib  MODULE-IDENTITY
    LAST-UPDATED "201706060000Z" -- June 6, 2017
    ORGANIZATION  "NBS"
    CONTACT-INFO
        "For technical support, please contact your service channel"

    DESCRIPTION
        "MIB for representing SFF MSA standards"

    ::= { nbs 204 }

-- *******************************************************************
-- NBS-SFF-MIB Objects Identifier Definition
-- *******************************************************************
nbsSffObjects  OBJECT-IDENTITY
    STATUS current
    DESCRIPTION
        "all MIB objects in nbsSFF MIB."
::= { nbsSffMib 1 }

-- *******************************************************************
-- Groups in NBS-SFF-MIB - all under nbsSffObjects
-- *******************************************************************

 nbsSffMsaGrp  OBJECT-IDENTITY
    STATUS  current
    DESCRIPTION
        "All SFF MSA objects."
 ::= { nbsSffObjects 1 }

 nbsSffWdmGrp  OBJECT-IDENTITY
    STATUS  current
    DESCRIPTION
        "All DWDM MSA objects."
 ::= { nbsSffObjects 2 }

 nbsSffDiagnosticsGrp  OBJECT-IDENTITY
    STATUS  current
    DESCRIPTION
        "All Diagnostics objects."
 ::= { nbsSffObjects 3 }

 nbsSffMsxGrp  OBJECT-IDENTITY
    STATUS  current
    DESCRIPTION
        "All SFF MSA Extension objects."
 ::= { nbsSffObjects 4 }

-- *******************************************************************
-- Objects in the nbsSffMsaGrp Group.
-- *******************************************************************

nbsSffMsaTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSffMsaEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Operations, Administration, and Management information"
    ::= { nbsSffMsaGrp 1 }

nbsSffMsaEntry      OBJECT-TYPE
    SYNTAX  NbsSffMsaEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Represents a SFF MSA details of a port."
    INDEX { nbsSffMsaPhysicalIfIndex }
    ::= { nbsSffMsaTable 1 }

NbsSffMsaEntry ::= SEQUENCE {
    nbsSffMsaPhysicalIfIndex            InterfaceIndex,
    nbsSffMsaIdentifier                 INTEGER,
    nbsSffMsaExtIdentifier              INTEGER,
    nbsSffMsaOpticalConnector           INTEGER,
    nbsSffMsaTransceiverCodes           OCTET STRING,
    nbsSffMsaSerialEncoding             INTEGER,
    nbsSffMsaNominalBitRate             INTEGER,
    nbsSffMsaLinkLengthSmfKm            INTEGER,
    nbsSffMsaLinkLengthSmf100m          INTEGER,
    nbsSffMsaLinkLengthMmf10m           INTEGER,
    nbsSffMsaLinkLength625Mmf10m        INTEGER,
    nbsSffMsaCopperLinkLength           INTEGER,
    nbsSffMsaVendorName                 DisplayString,
    nbsSffMsaVendorOUI                  OCTET STRING,
    nbsSffMsaVendorPartNumber           DisplayString,
    nbsSffMsaVendorRevision             DisplayString,
    nbsSffMsaBaseChecksumMatch          INTEGER,
    nbsSffMsaLossOfSignalImplemented    INTEGER,
    nbsSffMsaLossOfSignalInverted       INTEGER,
    nbsSffMsaTxFault                    INTEGER,
    nbsSffMsaTxDisable                  INTEGER,
    nbsSffMsaRateSelectImplemented      INTEGER,
    nbsSffMsaMaxBitRate                 INTEGER,
    nbsSffMsaMinBitRate                 INTEGER,
    nbsSffMsaVendorSerialNumber         DisplayString,
    nbsSffMsaVendorDateCode             DisplayString,
    nbsSffMsaExtChecksumMatch           INTEGER
}

nbsSffMsaPhysicalIfIndex  OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "ifIndex from MIB2"

    REFERENCE   "rfc1213 (MIB-II)"

    ::= { nbsSffMsaEntry 1 }

nbsSffMsaIdentifier  OBJECT-TYPE
    SYNTAX      INTEGER {
      unknown               (1),
      gbic                  (2),
      moduleSolderedToBoard (3),
      sfpTransceiver        (4),
      threeHundredPinXBI    (5),
      xenpak                (6),
      xfp                   (7),
      xff                   (8),
      xfpe                  (9),
      xpak                  (10),
      x2                    (11),
      dwdm                  (12),
      qsfp                  (13),
      qsfpPlus              (14),
      cfp                   (15),
      cxp                   (16),
      mrvCxp                (130) -- 0x81 vendor-specific pre-MSA
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The MSA Identifier as reported in the MSA memory map, +1.

         Some of these MSA Identifiers are also represented in
         nbsCmmcPortType from the NBS-CMMC-MIB:

         nbsSffMsaIdentifier  nbsCmmcPortType
         -------------------  ---------------
                  gbic   (2)  gbic (147)
        sfpTransceiver   (4)  sfp  (125)
                   xfp   (7)  xfp  (197)
                  qsfp  (13)  qsfp (219)
                 qsfp+  (14)  qsfp (219)
                   cfp  (15)  cfp  (221)
                   cxp  (16)  cxp  (220)
                mrvCxp (130)  cxp  (220)"

    REFERENCE
        "Specification for SFP MSA, Table 3.2
         Specification for XFP MSA v4.5 section 5.2 & table 32
         InfiniBand Architecture Specification Annex A6, section 7.6.3
         CFP MSA Hardware Specification, Table 14 CFP NVR 1"

    ::= { nbsSffMsaEntry 2 }

nbsSffMsaExtIdentifier  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The field should be set to 04h for all SFP modules indicating
         serial ID module definition.

         Not supported value: 0"

    REFERENCE   "Specification for SFP MSA"

    ::= { nbsSffMsaEntry 3 }

nbsSffMsaOpticalConnector OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Optical Connector as reported in the MSA memory map, +1.

         Here is the list of values:
         1 - unknown
         2 - SC
         3 - Fiber Channel Style 1 copper connector
         4 - Fiber Channel Style 2 copper connector
         5 - BNC/TNC
         6 - Fiber Channel coaxial headers
         7 - Fiberjack
         8 - LC
         9 - MT-RJ
        10 - MU
        11 - SG
        12 - Optical pigtail
        13 - MPO Parllel Optic
        14 to 32 - Reserved
        33 - HSSDC II
        34 - Copper pigtail
        35 - RJ45
        36 to 128 - Reserved
        -- start InfiniBand Annex A6 (CXP)
        48 (30h: Passive Copper Cable Assembly)
        49 (31h: Active Copper Cable Assembly (ref. Byte 147))
        50 (32h: Active Optical Cable Assembly)
        51 (33h: Optical Transceiver w/ optical connector)
        -- end InfiniBand Annex A6 (CXP)
        129 - firewireA (MRV Specific)
        130 - cuRJ45 (MRV Specific)
        131 - cuRJ45 with LEDs (MRV Specific)
        132 - coaxBNC (MRV Specific)
        133 - sataDevicePlug (MRV Specific)
        134 - sataHostPlug (MRV Specific)
        135 - miniCoax (MRV Specific)
        136 to 256 - Vendor specific"

    REFERENCE
        "Specification for SFP MSA, Table 3.3, and
         InfiniBand Architecture Specification Annex A6, section 7.6.3"

    ::= { nbsSffMsaEntry 4 }

nbsSffMsaTransceiverCodes  OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(8..11))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The following bit significant indicators define the
         electronic or optical interfaces that are supported by the
         SFP transceiver. At least one bit shall be set in this field.
         For Fibre Channel SFPs, the Fibre Channel speed, transmission
         media, transmitter technology, and distance capability shall
         all be indicated.

           Reserved Standard Compliance Codes

          BitIndex  Byte  Bit  Description
                     3    0-7  Reserved
                     4    4-7  Reserved

           SONET Compliance codes

             12      4     3 - Reserved
             13      4     2 - OC48 Long reach
             14      4     1 - OC48 Intermediate reach
             15      4     0 - OC48 Short reach

             16      5     7 - Reserved
             17      5     6 - OC 12 Single mode long reach
             18      5     5 - OC 12 Single mode inter reach
             19      5     4 - OC 12 Multi-mode short reach
             20      5     3 - Reserved
             21      5     2 - OC 3 Single mode long reach
             22      5     1 - OC 3 Single mode inter reach
             23      5     0 - OC 3 Multi-mode short reach

           Gigabit Ethernet Compliance codes
            24-27    6    4-7 - Reserved
             28      6    3 - 1000BASE-T
             29      6    2 - 1000BASE-CX
             30      6    1 - 1000BASE-LX
             31      6    0 - 1000BASE-SX

           Fiber Channel link length
             32      7    7 - Very long distance
             33      7    6 - Short distance
             34      7    5 - Intermediate distance
             35      7    4 - Long distance

           Fibre Channel transmitter technology
            36-37    7    2 to 3 - Reserved
             38      7    1 - Longwave laser
             39      7    0 - Electrical inter-enclosure

             40      8    7 - Electrical intra-enclosure
             41      8    6 - Shortwave laster without OFC
             42      8    5 - Shortwave laster with OFC
             43      8    4 - Longwave laser
            44-47    8    0 to 3 - Reserved

           Fiber channel transmission media
             48      9    7 - Twin Axial pair
             49      9    6 - Shielded Twisted Pair
             50      9    5 - Miniature coax
             51      9    4 - Video coax
             52      9    3 - Multi-mode, 62.5m
             53      9    2 - Multi-mode, 50 m
             54      9    1 - Reserved
             55      9    0 - Single Mode

          Fiber channel speed
            56-58   10    5-7 - Reserved
             59     10    4 - 400 MBps
             60     10    3 - Reserved
             61     10    2 - 200 MBps
             62     10    1 - Reserved
             63     10    0 - 100 MBps"

    REFERENCE  "Specification for SFP MSA, Table 3.4"

    ::= {nbsSffMsaEntry  5 }

nbsSffMsaSerialEncoding OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported   (1),
        lineCode8To10  (2),
        lineCode4To5   (3),
        nrz            (4),
        manchester     (5),
        sonetScrambled (6),
        unspecified    (7)  -- This was missing from Table 3.5 of
    }                       -- SFP MSA
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The encoding value indicates the serial encoding mechanism
         that is the nominal design target of the particular
         transceiver. The value shall be contained in the serial data.
         For XFPs this object must return notSupported, and user should
         refer to these MIB objects
               nbsXfpSerialEncodingRZ
               nbsXfpSerialEncodingNRZ
               nbsXfpSerialEncodingSonetScrm
               nbsXfpSerialEncoding8B10B
               nbsXfpSerialEncoding64B"

    REFERENCE   "Specification for SFP MSA, Table 3.5"

    ::= { nbsSffMsaEntry 6 }

nbsSffMsaNominalBitRate OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The nominal bit rate (BR, nominal) is specified in units of
         100 Megabits per second, rounded off to the nearest 100
         Megabits per second. The bit rate includes those bits
         necessary to encode and delimit the signal as well as those
         bits carrying data information. A value of 0 indicates that
         the bit rate is not specified and must be determined from the
         transceiver technology. The actual information transfer rate
         will depend on the encoding of the data, as defined by the
         encoding value."
    REFERENCE   "Specification for SFP MSA, BR, Nominal"

    ::= { nbsSffMsaEntry 7 }

nbsSffMsaLinkLengthSmfKm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies the link length that is supported by the
         transceiver while operating in compliance with the applicable
         standards using single mode fiber. The value is in units of
         kilometers. A value of 255 means that the transceiver supports
         a link length greater than 254 km. A value of zero means that
         the transceiver does not support single mode fiber or that the
         length information must be determined from the transceiver
         technology. XFP uses this object for the same purpose."
    REFERENCE   "Specification for SFP MSA, Length (9m) - Km and
                  section 5.22 of XFP MSA INF_8077i"

    ::= { nbsSffMsaEntry 8 }

nbsSffMsaLinkLengthSmf100m OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies the link length that is supported by the
         transceiver while operating in compliance with the applicable
         standards using single mode fiber. The value is in units of
         100 meters. A value of 255 means that the transceiver supports
         a link length greater than 25.4 km. A value of zero means that
         the transceiver does not support single mode fiber or that the
         length information must be determined from the transceiver
         technology."
    REFERENCE   "Specification for SFP MSA, Length (9m) and section
                 5.22 of XFP MSA INF_8077i"


    ::= { nbsSffMsaEntry 9 }

nbsSffMsaLinkLengthMmf10m OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies link length that is supported by the
         transceiver while operating in compliance with applicable
         standards using 50 micron multimode OM2 [500MHz*km at 850nm,]
         fiber. The value is in units of 10 meters. A value of 255
         means that the transceiver supports a link length greater
         than 2.54 km. A value of zero means that the transceiver
         does not support 50 micron multimode fiber or that the
         length information must be determined from the transceiver
         technology."
    REFERENCE   "Specification for SFP MSA, Length (50m)"

    ::= { nbsSffMsaEntry 10 }

nbsSffMsaLinkLength625Mmf10m OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies link length that is supported by the
         transceiver while operating in compliance with applicable
         standards using 62.5 micron multimode OM1 [200 MHz*km at
         850nm, 500 MHz*km at 1310nm] fiber. The value is in units
         of 10 meters. A value of 255 means that the transceiver
         supports a link length greater than 2.54 km. A value of zero
         means that the transceiver does not support 62.5 micron
         multimode fiber or that the length information must determined
         from the transceiver technology. It is common for a multimode
         transceiver to support OM1, OM2 and OM3 fiber."

    REFERENCE   "Specification for SFP MSA, Length (62.5m) and
                section 5.22 of XFP MSA INF_8077i"

    ::= { nbsSffMsaEntry 11 }

nbsSffMsaCopperLinkLength OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies the minimum link length that is supported
         by the transceiver while operating in compliance with the
         applicable standards using copper cable. The value is in units
         of 1 meter. A value of 255 means that the transceiver supports
         a link length greater than 254 meters. A value of zero means
         that the transceiver does not support copper cables or that
         the length information must be determined from the transceiver
         technology. Further information about the cable design,
         equalization, and connectors is usually required to guarantee
         meeting a particular length requirement."
    REFERENCE   "Specification for SFP MSA, Length Copper & section
                 5.22 of XFP MSA INF_8077i"

    ::= { nbsSffMsaEntry 12 }

nbsSffMsaVendorName OBJECT-TYPE
    SYNTAX       DisplayString(SIZE(0..16))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The vendor name is a 16 character field that contains ASCII
         characters, The vendor name shall be the full name of the
         corporation, a commonly accepted abbreviation of the name of
         the corporation, the SCSI company code for the corporation,
         or the stock exchange code for the corporation. At least one
         of the vendor name or the vendor OUI fields shall contain
         valid serial data."
    REFERENCE  "Specification for SFP MSA, Vendor name"

    ::= { nbsSffMsaEntry 13 }

nbsSffMsaVendorOUI OBJECT-TYPE
    SYNTAX       OCTET STRING (SIZE(3))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The vendor organizationally unique identifier field (vendor
         OUI) is a 3-byte field that contains the IEEE Company
         Identifier for the vendor. A value of all zero in the 3-byte
         field indicates that the Vendor OUI is unspecified."
    REFERENCE  "Specification for SFP MSA, Vendor OUI"

    ::= { nbsSffMsaEntry 14 }

nbsSffMsaVendorPartNumber OBJECT-TYPE
    SYNTAX       DisplayString(SIZE(0..16))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The vendor part number (vendor PN) is a 16-byte field that
         contains ASCII characters, left-aligned, defining the vendor
         part number or product name.

         Unlike the MSA standard, agent returns size 0 string if the
         part number is unspecified and there will be no white space
         padding."
    REFERENCE  "Specification for SFP MSA, Vendor PN"

    ::= { nbsSffMsaEntry 15 }

nbsSffMsaVendorRevision OBJECT-TYPE
    SYNTAX       DisplayString(SIZE(0..4))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The vendor revision number (vendor rev) is a 4-byte field that
         contains ASCII characters, defining the vendor's product
         revision number.

         Unlike the MSA standard, agent returns size 0 string if the
         part number is unspecified and there will be no white space
         padding.

         This is a two byte string for XFP, four bytes for others."

    REFERENCE  "Specification for SFP MSA, Vendor Rev and XFP for MSA
                INF8077i section 5.32"

    ::= { nbsSffMsaEntry 16 }

nbsSffMsaBaseChecksumMatch OBJECT-TYPE
    SYNTAX      INTEGER {
        no             (1),
        yes            (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The check code is a one byte code that can be used to verify
         that the first 64 (0-63) bytes of serial information in the
         SFP transceiver is valid.Returns yes if checksum matches, no
         if checksum doesn't match. For XFPs, The check code shall be
         the low order 8 bits of the sum of the contents of all the
         bytes from byte 128 to byte 190, inclusive."
    REFERENCE  "Specification for SFP MSA, CC_BASE and Specification
                for XFP for MSA INF8077i section 5.36"

    ::= {nbsSffMsaEntry  17  }

nbsSffMsaLossOfSignalImplemented OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Byte 65 Bit 1. Signal as defined in the specification"
    REFERENCE  "Specification for SFP MSA Table 3.6"

    ::= { nbsSffMsaEntry 18 }

nbsSffMsaLossOfSignalInverted OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Byte 65 Bit 2. Signal as defined in the specification"
    REFERENCE  "Specification for SFP MSA Table 3.6"

    ::= { nbsSffMsaEntry 19 }

nbsSffMsaTxFault OBJECT-TYPE
    SYNTAX      INTEGER {
        off  (1),
        on   (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 65 Bit 3.TX_FAULT signal implemented. Reset definition
          in Section III and Laser Fault condition, Generated by laser
          safety system."
    REFERENCE   "Specification for SFP MSA Table 3.6 and
                Specification for XFP MSA INF8077i, section 5.11 &
                table 39"

    ::= { nbsSffMsaEntry 20 }

nbsSffMsaTxDisable OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 65 Bit 4.TX_DISABLE is implemented and disables the
          serial output."
    REFERENCE   "Specification for SFP MSA Table 3.6"

    ::= { nbsSffMsaEntry 21 }

nbsSffMsaRateSelectImplemented OBJECT-TYPE
    SYNTAX      INTEGER {
        no      (1),
        yes     (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 65 Bit 5.If this bit is set then active control of the
          rate select pin is required to change rates. If bit is not
          set, no control of pin is required. In all cases, compliance
          with multiple rate standards should be determined by
          Transceiver codes in bytes 4,5,6, and 10. See table 3.4"
    REFERENCE   "Specification for SFP MSA Table 3.6"

    ::= { nbsSffMsaEntry 22 }

nbsSffMsaMaxBitRate OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The upper bit rate limit at which the SFP transceiver will
         still meet its specifications (BR, max) is specified in units
         of 1% above the nominal bit rate. A value of zero indicates
         that this field is not specified."
    REFERENCE  "Specification for SFP MSA  BR,max"

    ::= { nbsSffMsaEntry 23 }

nbsSffMsaMinBitRate OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The lower bit rate limit at which the SFP transceiver will
         still meet its specifications (BR, min) is specified in units
         of 1% below the nominal bit rate. A value of zero indicates
         that this field is not specified."
    REFERENCE  "Specification for SFP MSA  BR,min"

    ::= { nbsSffMsaEntry 24 }

nbsSffMsaVendorSerialNumber OBJECT-TYPE
    SYNTAX       DisplayString(SIZE(0..16))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The vendor serial number (vendor SN) is a 16 character field
         that contains ASCII characters, left-aligned and padded on
         the right with ASCII spaces (20h), defining the vendor's
         serial number for the SFP transceiver. A value of all zero
         in the 16-byte field indicates that the vendor SN is
         unspecified."

    REFERENCE  "Specification for SFP MSA  Vendor SN and XFP for MSA
                INF8077i section 5.38"

    ::= { nbsSffMsaEntry 25 }

nbsSffMsaVendorDateCode OBJECT-TYPE
    SYNTAX       DisplayString(SIZE(6..8))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The date code is an 8-byte field that contains the vendor's
         date code in ASCII characters. The date code is mandatory."
    REFERENCE  "Specification for SFP MSA Table 3.7 and XFP for MSA
                INF8077i section 5.39"

    ::= { nbsSffMsaEntry 26 }

nbsSffMsaExtChecksumMatch OBJECT-TYPE
    SYNTAX      INTEGER {
        no             (1),
        yes            (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The check code is a one byte code that can be used to verify
         that the first 32 bytes of extended serial information in the
         SFP transceiver is valid. The check code shall be the low
         order 8 bits of the sum of the contents of all the bytes from
         byte 64 to byte 94, inclusive."
    REFERENCE  "Specification for SFP MSA, CC_BASE"

    ::= {nbsSffMsaEntry  27  }


-- **********************************************************
-- nbsSffWdmGrp DWDM objects
-- **********************************************************

nbsSffWdmTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSffWdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Operations, Administration, and Management information"
    ::= { nbsSffWdmGrp 1 }

nbsSffWdmEntry OBJECT-TYPE
    SYNTAX  NbsSffWdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Represents WDM properties of a port."
    INDEX { nbsSffMsaPhysicalIfIndex }
    ::= { nbsSffWdmTable 1 }

NbsSffWdmEntry ::= SEQUENCE {
    nbsSffWdmClassOfPower               INTEGER,
    nbsSffWdmClassOfTemperature         INTEGER,
    nbsSffWdmClassOfWdm                 INTEGER,
    nbsSffWdmOpticalReach               INTEGER,
    nbsSffWdmMaxCaseTemperature         INTEGER,
    nbsSffWdmMinCaseTemperature         INTEGER,
    nbsSffWdmMaxSupplyCurrent           INTEGER,
    nbsSffWdmNumberOfChannels           INTEGER,
    nbsSffWdmChannelSpacing             INTEGER,
    nbsSffWdmVariableDecisionThreshold  INTEGER,
    nbsSffWdmWavelengthMonitorType      INTEGER,
    nbsSffWdmExtTransmitPowerType       INTEGER,
    nbsSffWdmVariableOpticalAttenuator  INTEGER,
    nbsSffWdmPilotToneFunctionality     INTEGER,
    nbsSffWdmOptionalInterruptPin       INTEGER,
    nbsSffWdmLaserWavelength            DisplayString,
    nbsSffWdmFrequency                  NbsTcMHz,
    nbsSffWdmChannelBand                NbsCmmcChannelBand,
    nbsSffWdmChannelNumber              INTEGER
}

nbsSffWdmClassOfPower OBJECT-TYPE
    SYNTAX      INTEGER {
        under1W          (1),
        oneToOneAndHalfW (2),
        overOneAndHalfW  (3),
        reserved         (4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Extended identifier of class of Power."
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.3"

    ::= {nbsSffWdmEntry  1 }

nbsSffWdmClassOfTemperature OBJECT-TYPE
    SYNTAX      INTEGER {
        class0           (1),
        class1           (2),
        class2           (3),
        class3           (4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Extended identifier of class of Temperature.
         class0 - Temperature in [-5, 70C]
         class1 - Temperature in [-40, 85C]
         class2 - reserved
         class3 - defined by MIB objects nbsSffDwdmMaxCaseTemperature &
                  nbsSffDwdmMinCaseTemperature"
    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.3"

    ::= {nbsSffWdmEntry  2 }

nbsSffWdmClassOfWdm OBJECT-TYPE
    SYNTAX      INTEGER {
        noWdm           (1),
        cwdm            (2),
        dwdm            (3),
        reserved        (4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Extended identifier of class of WDM.
         1 - No WDM
         2 - CWDM
         3 - DWDM
         4 - Reserved"
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.3"

    ::= {nbsSffWdmEntry  3 }

nbsSffWdmOpticalReach OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies the link length in kilometers that is
         supported by the transceiver while operating in compliance
         with the applicable standards using single mode fiber."
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.8"

    ::= { nbsSffWdmEntry 4 }

nbsSffWdmMaxCaseTemperature OBJECT-TYPE
    SYNTAX      INTEGER (-2147483647..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This field defines the maximum operating case temperature in
         Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs,
         this value is in byte 190."
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.9
                and Specification for XFP MSA, INF8077i section 5.35"
    DEFVAL { 70 }
    ::= { nbsSffWdmEntry 5 }

nbsSffWdmMinCaseTemperature OBJECT-TYPE
    SYNTAX      INTEGER (-2147483647..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This field defines the minimum operating case temperature
         in Celsius."
    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.10"

    ::= { nbsSffWdmEntry 6 }

nbsSffWdmMaxSupplyCurrent OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This field defines the maximum supply current, in milli Amps,
         which the module will consume under worst case conditions."
    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.11"

    ::= { nbsSffWdmEntry 7 }

nbsSffWdmNumberOfChannels OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This specifies the tuning range from 1 to 63, where 1
         indicates this module is not tunable by user commands."
    REFERENCE   "Specification for DWDM SFP Transceiver, section 2.2.12"

    ::= { nbsSffWdmEntry 8 }

nbsSffWdmChannelSpacing OBJECT-TYPE
    SYNTAX      INTEGER {
        notTunable    (1),
        ghz50         (2),
        ghz100        (3),
        ghz200        (4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This field identifies the densest channel spacing the module
         is compatible with and the number of channels over which the
         module may be tuned by user command."
    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.12"

    ::= { nbsSffWdmEntry 9 }

nbsSffWdmVariableDecisionThreshold  OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported    (1),
        supported       (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Variable Decission Threshold."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  10 }

nbsSffWdmWavelengthMonitorType  OBJECT-TYPE
    SYNTAX      INTEGER {
        wavelength       (1),
        laserTemperature (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Wavelength monitor type in A2 byte."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  11 }

nbsSffWdmExtTransmitPowerType  OBJECT-TYPE
    SYNTAX      INTEGER {
        pwrDefault      (1),
        pwrExtended     (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Extended Transmit Power Type."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  12 }

nbsSffWdmVariableOpticalAttenuator  OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Variable Optical Atttenuator."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  13 }

nbsSffWdmPilotToneFunctionality  OBJECT-TYPE
    SYNTAX      INTEGER {
        pilotToneNone               (1),
        pilotToneDetection          (2),
        pilotToneInjection          (3),
        pilotToneInjectionDetection (4),
        pilotToneEnhanced           (5)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Pilot Tone Functionality."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  14 }

nbsSffWdmOptionalInterruptPin  OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported   (1),
        supported      (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "DWDM Optional Interrupt Pin."

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.14"

    ::= {nbsSffWdmEntry  15 }

nbsSffWdmLaserWavelength OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..150))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Nominal transmitter output wavelength.

         For SFPs, per Specification for DWDM SFP Transceiver,
         section 2.2.1, The laser wavelength
         is equal to the 16 bit integer value in nm (16 bit value with
         byte 60 as high order byte and byte 61 as low order byte) and
         with the fractional part of the wavelength in units of 0.01nm
         (byte 62).

         For XFPs,per specification for INF8077i, see section 5.33"

    REFERENCE  "Specification for DWDM SFP Transceiver, section 2.2.18"

    ::= { nbsSffWdmEntry 16 }

nbsSffWdmFrequency  OBJECT-TYPE
    SYNTAX      NbsTcMHz
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Nominal transmitter frequency, in MHz"

    ::= {nbsSffWdmEntry  17 }

nbsSffWdmChannelBand  OBJECT-TYPE
    SYNTAX      NbsCmmcChannelBand
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ITU Channel Band"
    ::= {nbsSffWdmEntry  18 }

nbsSffWdmChannelNumber  OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ITU Channel Number"

    ::= {nbsSffWdmEntry  19 }


-- ************************
-- Diagnostics objects ****
-- ************************

nbsSffDiagsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSffDiagsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Operations, Administration, and Management information"
    ::= { nbsSffDiagnosticsGrp 1 }

nbsSffDiagsEntry  OBJECT-TYPE
    SYNTAX  NbsSffDiagsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Represents Digital Diagnostics of a port."
    INDEX { nbsSffMsaPhysicalIfIndex }
    ::= { nbsSffDiagsTable 1 }

NbsSffDiagsEntry ::= SEQUENCE {
    nbsSffDiagsRateIdentifier             INTEGER,
    nbsSffDiagsLinkLengthOm3              INTEGER,
    nbsSffDiagsLaserWavelength            INTEGER,
    nbsSffDiagsLROutputImplemented        INTEGER,
    nbsSffDiagsPowerLevelDeclaration      INTEGER,
    nbsSffDiagsCooledTranDeclaration      INTEGER,
    nbsSffDiagsAddressChangeRequired      INTEGER,
    nbsSffDiagsPowerMeasurementType       INTEGER,
    nbsSffDiagsExternallyCalibrated       INTEGER,
    nbsSffDiagsInternallyCalibrated       INTEGER,
    nbsSffDiagsDDMonitoringImplemented    INTEGER,
    nbsSffDiagsOptRateSelectControl       INTEGER,
    nbsSffDiagsOptAppSelectControl        INTEGER,
    nbsSffDiagsOptSoftRSControlMon        INTEGER,
    nbsSffDiagsOptSoftRxLoSMonitoring     INTEGER,
    nbsSffDiagsOptSoftTxFaultMonitoring   INTEGER,
    nbsSffDiagsOptSoftTxDisable           INTEGER,
    nbsSffDiagsOptAlarmWarningFlags       INTEGER,
    nbsSffDiags8472Compliance             INTEGER,
    nbsSffDiagsTemperature                INTEGER,
    nbsSffDiagsTempLowAlarm               INTEGER,
    nbsSffDiagsTempLowWarn                INTEGER,
    nbsSffDiagsTempHighWarn               INTEGER,
    nbsSffDiagsTempHighAlarm              INTEGER,
    nbsSffDiagsVoltage                    DisplayString,
    nbsSffDiagsVoltLowAlarm               INTEGER,
    nbsSffDiagsVoltLowWarn                INTEGER,
    nbsSffDiagsVoltHighWarn               INTEGER,
    nbsSffDiagsVoltHighAlarm              INTEGER,
    nbsSffDiagsBiasCurrent                DisplayString,
    nbsSffDiagsBiasLowAlarm               INTEGER,
    nbsSffDiagsBiasLowWarn                INTEGER,
    nbsSffDiagsBiasHighWarn               INTEGER,
    nbsSffDiagsBiasHighAlarm              INTEGER,
    nbsSffDiagsTxPower                    DisplayString,
    nbsSffDiagsTxPowerLowAlarm            INTEGER,
    nbsSffDiagsTxPowerLowWarn             INTEGER,
    nbsSffDiagsTxPowerHighWarn            INTEGER,
    nbsSffDiagsTxPowerHighAlarm           INTEGER,
    nbsSffDiagsRxPower                    DisplayString,
    nbsSffDiagsRxPowerLowAlarm            INTEGER,
    nbsSffDiagsRxPowerLowWarn             INTEGER,
    nbsSffDiagsRxPowerHighWarn            INTEGER,
    nbsSffDiagsRxPowerHighAlarm           INTEGER,
    nbsSffDiagsDataReadyBarState          INTEGER,
    nbsSffDiagsRxLosState                 INTEGER,
    nbsSffDiagsTxFaultState               INTEGER,
    nbsSffDiagsSoftRateSelect             INTEGER,
    nbsSffDiagsRateSelectState0           INTEGER,
    nbsSffDiagsRS1State                   INTEGER,
    nbsSffDiagsSoftTxDisableSelect        INTEGER,
    nbsSffDiagsTxDisableState             INTEGER,
--  Calibration constants
    nbsSffDiagsBiasCurrentSlope           DisplayString,
    nbsSffDiagsBiasCurrentOffset          INTEGER,
    nbsSffDiagsTxPowerSlope               DisplayString,
    nbsSffDiagsTxPowerOffset              INTEGER,
    nbsSffDiagsTemperatureSlope           DisplayString,
    nbsSffDiagsTemperatureOffset          INTEGER,
    nbsSffDiagsVoltageSlope               DisplayString,
    nbsSffDiagsVoltageOffset              INTEGER,

--  Extended module control
    nbsSffDiagsPowerLevelSelect           INTEGER,
    nbsSffDiagsPowerLevelOpState          INTEGER,
    nbsSffDiagsSoftRSSelect               INTEGER
}

nbsSffDiagsRateIdentifier  OBJECT-TYPE
    SYNTAX      INTEGER {
       notSupported (1),
       rate421G     (2),
       rate842GRx   (3),
       rate842GRxTx (4),
       rate842GTx   (5)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The rate identifier byte refers to several (optional) industry
         standard definitions of Rate_Select or Application_Select
         control behaviors, intended to manage transceiver optimization
         for multiple operating rates."

    REFERENCE   "Table 3.6a of SFF-8472 Rev 10.3 Diagnostic monitoring
                 interface for optical transceiver"

    ::= { nbsSffDiagsEntry 1 }

nbsSffDiagsLinkLengthOm3 OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This value specifies link length that is supported by the
         transceiver while operating in compliance with applicable
         standards using 50 micron multimode OM3 [2000 MHz*km] fiber.
         The value is in units of 10 meters. A value of 255 means that
         the transceiver supports a link length greater than 2.54 km.
         A value of zero means that the transceiver does not support
         50 micron multimode fiber or that the length information must
         be determined from the transceiver technology."
    REFERENCE   "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3)"

    ::= { nbsSffDiagsEntry 2 }

nbsSffDiagsLaserWavelength OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Nominal transmitter output wavelength at room temperature. 16
         bit value with byte 60 as high order byte and byte 61 as low
         order byte. The laser wavelength is equal to the the 16 bit
         integer value in nm. This field allows the user to read the
         laser wavelength directly, so it is not necessary to infer
         it from the transceiver Code for Electronic Compatibility
         (bytes 3 to 10). This also allows specification of wavelengths
         not covered in bytes 3 to 10, such as those used in coarse WDM
         systems."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3)"

    ::= { nbsSffDiagsEntry 3 }

nbsSffDiagsLROutputImplemented OBJECT-TYPE
    SYNTAX      INTEGER {
        no            (1),
        yes           (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 64, bit 0. Value of 1 identifies a conventional
          limiting (or unspecified) receiver output. Value of 2
          identifies a linear receiver output."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.7"

    ::= { nbsSffDiagsEntry 4 }

nbsSffDiagsPowerLevelDeclaration OBJECT-TYPE
    SYNTAX      INTEGER {
        level1        (1),
        level2        (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 64, bit 1. Value 1 identifies Power Level 1 (or
          unspecified) requirements. Value 2 identifies a Power
          Level2 requirements."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.7"

    ::= { nbsSffDiagsEntry 5 }

nbsSffDiagsCooledTranDeclaration OBJECT-TYPE
    SYNTAX      INTEGER {
        uncooled      (1),
        cooled        (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         " Byte 64, bit 2. Value 1 identifies a conventional
           uncooled (or unspecified) laser implementation. Value 2
           identifies a cooled laser transmitter implementation."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.7"

    ::= { nbsSffDiagsEntry 6 }

nbsSffDiagsAddressChangeRequired OBJECT-TYPE
    SYNTAX      INTEGER {
        no            (1),
        yes           (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 92, bit 2 indicates whether or not it is necessary for
          the host to perform an address change sequence before
          accessing information at 2-wire serial address A2h. If this
          bit is not set, the host may simply read from either address,
          A0h or A2h, by using that value in the address byte during
          the 2-wire communication sequence. If the bit is set, the
          defined sequence must be executed prior to accessing
          information at address A2h."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.9"

    ::= { nbsSffDiagsEntry 7 }

nbsSffDiagsPowerMeasurementType OBJECT-TYPE
    SYNTAX      INTEGER {
        oma           (1),
        averagePower  (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 92, bit 3 indicates whether the received power
          measurement represents average input optical power or OMA.
          If the bit is set, average power is monitored. If it is not,
          OMA is monitored. For XFPs, the address location would be
          byte 220, bit 3"
    REFERENCE  "Specification for Diagnostic monitoring interface for
                optical transceiver (SFF-8472 rev 10.3), Table 3.9
                Specification for XFP for MSA, INF8077i, section 5.40
                table 56"

    ::= { nbsSffDiagsEntry 8 }

nbsSffDiagsExternallyCalibrated OBJECT-TYPE
    SYNTAX      INTEGER {
        no            (1),
        yes           (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 92, bit 4 Externally Calibrated
          Two calibration options are possible if bit 6 has been set
          indicating that digital diagnostic monitoring has been
          implemented. If bit 4 is set, the reported values are A/D
          counts which must be converted to real world units using
          calibration values read using 2 wire serial address
          1010001X (A2h) from bytes 56 to 95."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.9"

    ::= { nbsSffDiagsEntry 9 }

nbsSffDiagsInternallyCalibrated OBJECT-TYPE
    SYNTAX      INTEGER {
        no            (1),
        yes           (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 92, bit 5 Internally Calibrated.
          Two calibration options are possible if bit 6 has been set
          indicating that digital diagnostic monitoring has been
          implemented. If bit 5, Internally calibrated is set, the
          transceiver directly reports calibrated values in units of
          current, power etc."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.9"

    ::= { nbsSffDiagsEntry 10 }

nbsSffDiagsDDMonitoringImplemented OBJECT-TYPE
    SYNTAX      INTEGER {
        no            (1),
        yes           (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 92, bit 6. If this bit is set indicating that digital
          diagnostic monitoring has been implemented, received power
          monitoring, transmitted power monitoring, bias current
          monitoring, supply voltage monitoring and temperature
          monitoring must all be implemented. Additionally, alarm and
          warning thresholds must be written as specified in this
          document at locations 00 to 55 on 2 wire serial address
          1010001X (A2h)"

    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.9"

    ::= { nbsSffDiagsEntry 11 }

nbsSffDiagsOptRateSelectControl OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Byte 93 bit 1. Optional Rate Select control implemented per
          SFF-8431. Sets to 1 if not implemented, 2 if implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.10"

    ::= { nbsSffDiagsEntry 12 }

nbsSffDiagsOptAppSelectControl OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 2. Optional Application Select control
          implemented per SFF-8079. Sets to 1 if not
          implemented, 2 if implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.10"

    ::= { nbsSffDiagsEntry 13 }

nbsSffDiagsOptSoftRSControlMon OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 3. Optional soft RATE_SELECT control and
          monitoring implemented. Sets to 1 if not implemented,
          2 if implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                optical transceiver (SFF-8472 rev 10.3), Table 3.10
                and Table 3.11"

    ::= { nbsSffDiagsEntry 14 }

nbsSffDiagsOptSoftRxLoSMonitoring OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 4. Optional soft RX_LOS monitoring
          implemented. Sets to 1 if not implemented, 2 if implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                optical transceiver (SFF-8472 rev 10.3), Table 3.10
                and Table 3.11"

    ::= { nbsSffDiagsEntry 15 }

nbsSffDiagsOptSoftTxFaultMonitoring OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 5. Optional soft TX_FAULT monitoring
          implemented. Sets to 1 if not implemented, 2 if implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                optical transceiver (SFF-8472 rev 10.3), Table 3.10
                and Table 3.11"

    ::= { nbsSffDiagsEntry 16 }

nbsSffDiagsOptSoftTxDisable OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 6. Optional soft TX_DISABLE control and
          monitoring implemented.Sets to 1 if not implemented, 2 if
          implemented."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                optical transceiver (SFF-8472 rev 10.3), Table 3.10
                and Table 3.11"

    ::= { nbsSffDiagsEntry 17 }

nbsSffDiagsOptAlarmWarningFlags OBJECT-TYPE
    SYNTAX      INTEGER {
        notImplemented (1),
        implemented    (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Based on byte 93 bit 7. Optional Alarm/warning flags
          implemented for all monitored quantities.Sets to 1 if
          not implemented, 2 if implemented. See Table 3.18"
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.10"

    ::= { nbsSffDiagsEntry 18 }

nbsSffDiags8472Compliance  OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported    (1),
        rev9dot3of8472  (2),
        rev9dot5of8472  (3),
        rev10dot2of8472 (4),
        rev10dot4of8472 (5),
        rev11dot0of8472 (6),
        rev11dot3of8472 (7),
        rev11dot4of8472 (8),
        rev12dot0of8472 (9),
        unallocated   (256)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Byte 94 contains an unsigned integer that indicates which
         feature set(s) are implemented in the transceiver."
    REFERENCE  "Specification for Diagnostic monitoring interface for
                 optical transceiver (SFF-8472 rev 10.3), Table 3.12"

    ::= {nbsSffDiagsEntry  19 }

nbsSffDiagsTemperature OBJECT-TYPE
    SYNTAX      INTEGER  (-2147483647..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Module temperature in centigradese."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 20 }

nbsSffDiagsTempLowAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined temperature for low alarm threshold in
         Centigrades."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15 and
                 XFP for MSA INF8077i table 35."

    ::= { nbsSffDiagsEntry 21 }

nbsSffDiagsTempLowWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined temperature for low warning threshold in
         Centigrades"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF8077i table 35."

    ::= { nbsSffDiagsEntry 22 }

nbsSffDiagsTempHighWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined temperature for high warning threshold in
         Centigrades"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF8077i table 35."

    ::= { nbsSffDiagsEntry 23 }

nbsSffDiagsTempHighAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined temperature for high alarm threshold in
         Centigrades"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 24 }

nbsSffDiagsVoltage OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Internally measured supply voltage in transceiver in the
         units of Volts. Bytes 98 & 99 of Address A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 25 }

nbsSffDiagsVoltLowAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined voltage for low alarm threshold in the
         units of Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15"

    ::= { nbsSffDiagsEntry 26 }

nbsSffDiagsVoltLowWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined voltage for low warning threshold in the
         units of Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15"

    ::= { nbsSffDiagsEntry 27 }

nbsSffDiagsVoltHighWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined voltage for high warning threshold in the
         units of Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15"

    ::= { nbsSffDiagsEntry 28 }

nbsSffDiagsVoltHighAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined voltage for high alarm threshold in the
         units of Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15"

    ::= { nbsSffDiagsEntry 29 }

nbsSffDiagsBiasCurrent OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Internally measured TX Bias Current in the units of mA.
         Bytes 100 & 101 of Address A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 30 }

nbsSffDiagsBiasLowAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined bias current for low alarm threshold in the
         units of mA"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 31 }

nbsSffDiagsBiasLowWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined bias current for low warning threshold in
         the units of mA"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 32 }

nbsSffDiagsBiasHighWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined bias current for high warning threshold in the
         units of mA"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 33 }

nbsSffDiagsBiasHighAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined bias current for high alarm threshold in the
         units of mA"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 34 }

nbsSffDiagsTxPower OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Measured TX output power in the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 35 }

nbsSffDiagsTxPowerLowAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Tx output power for low alarm threshold in the
         units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 36 }

nbsSffDiagsTxPowerLowWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Tx output power for low warning threshold in the
         units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 37 }

nbsSffDiagsTxPowerHighWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Tx output power for high warning threshold in the
         units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 38 }

nbsSffDiagsTxPowerHighAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Tx output power for high alarm threshold in
         the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 39 }

nbsSffDiagsRxPower OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Measured received optical power.
          Received power, RX_PWR, is given in uW by the
          following equation:
          Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD
          4 (16 bit unsigned integer) +
          Rx_PWR(3) * Rx_PWR AD
          3 (16 bit unsigned integer) +
          Rx_PWR(2) * Rx_PWR AD
          2 (16 bit unsigned integer) +
          Rx_PWR(1) * Rx_PWR AD (16 bit unsigned integer) +
          Rx_PWR(0)"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 40 }

nbsSffDiagsRxPowerLowAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Rx input power for low alarm threshold in
         the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 41 }

nbsSffDiagsRxPowerLowWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Rx input power for low warning threshold in
         the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 42 }

nbsSffDiagsRxPowerHighWarn OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Rx input power for high warning threshold in the
         units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 43 }

nbsSffDiagsRxPowerHighAlarm OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Predefined Rx input power for high alarm threshold in
         the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.15  and
                 XFP for MSA INF 8077i table 35."

    ::= { nbsSffDiagsEntry 44 }

nbsSffDiagsDataReadyBarState OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates transceiver has achieved power up and data is ready.
         Bit remains high until data is ready to be read at which time
         the device sets the bit low. Byte 110, bit 0 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 45 }

nbsSffDiagsRxLosState OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Digital state of the RX_LOS Output Pin. Updated within 100ms
         of change on pin. Byte 110, bit 1 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 46 }

nbsSffDiagsTxFaultState OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Digital state of the TX Fault Output Pin. Updated within
         100ms of change on pin. Byte 110, bit 2 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 47 }

nbsSffDiagsSoftRateSelect OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Read/write bit that allows software rate select control.
         Writing 1 selects full bandwidth operation. This bit is
         OR'd with the hard Rate_Select, AS(0) or RS(0) pin value.
         See Table 3.11 for timing requirements. Default at power
         up is logic zero/low. If Soft Rate Select is not implemented,
         the transceiver ignores the value of this bit. Note: Specific
         transceiver behaviors of this bit are identified in Table 3.6a
         and referenced documents. See Table 3.18a, byte 118, bit 3 for
         Soft RS(1) Select. Byte 110, bit 3 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 48 }

nbsSffDiagsRateSelectState0 OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Digital state of the SFP Rate_Select Input Pin. Updated within
         100ms of change on pin. Note: This pin is also known as AS(0)
         in SFF-8079 and RS(0) in SFF-8431. Byte 110, bit 4 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 49 }

nbsSffDiagsRS1State OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reserved for digital state of input pin AS(1) per SFF-8079 and
         RS(1) per SFF-8431. Updated within 100ms of change on pin. See
         A2h Byte 118, Bit 3 for Soft RS(1) Select control information.
         Byte 110, bit 5 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 50 }

nbsSffDiagsSoftTxDisableSelect OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Read/write bit that allows software disable of laser.
         Writing 1 disables laser. See Table 3.11 for enable/
         disable timing requirements. This bit is OR d with the hard
         TX_DISABLE pin value. Note, per SFP MSA TX_DISABLE pin is
         default enabled unless pulled low by hardware. If Soft TX
         Disable is not implemented, the transceiver ignores the value
         of this bit. Default power up value is zero/low.
         Byte 110, bit 6 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 51 }

nbsSffDiagsTxDisableState OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Digital state of the TX Disable Input Pin. Updated within
          100ms of change on pin."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 52 }

nbsSffDiagsBiasCurrentSlope OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (unsigned) calibration data, laser bias
          current measured in mA."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 53 }

nbsSffDiagsBiasCurrentOffset OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (signed two's complement) calibration data,
          laser bias current measured in mA."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 54 }

nbsSffDiagsTxPowerSlope OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (unsigned) calibration data, transmitter
          coupled output power in the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 55 }

nbsSffDiagsTxPowerOffset OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (signed two's complement) calibration data,
          transmitter coupled output power in the units of dBm."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 56 }

nbsSffDiagsTemperatureSlope OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (unsigned) calibration data, internal module
          temperature in C"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 57 }

nbsSffDiagsTemperatureOffset OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (signed two's complement) calibration data,
          internal module temperature in C"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 58 }

nbsSffDiagsVoltageSlope OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (unsigned) calibration data, internal module
          supply voltage in Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 59 }

nbsSffDiagsVoltageOffset OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Fixed decimal (signed two's complement) calibration data,
          internal module supply voltage in Volts."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.16"

    ::= { nbsSffDiagsEntry 60 }

nbsSffDiagsPowerLevelSelect OBJECT-TYPE
    SYNTAX      INTEGER {
        off        (1),
        on         (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Reserved for SFF-8431 Power Level (maximum power dissipation)
          enable.
          Value of zero disables Power Level 2 (1.0 Watt max).
          Value of one enables Power Level 2 (1.5 Watt max).
          Refer to Table 3.7 for Power Level declaration.
          Refer to Table 3.11 for timing."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.18a of A2h"

    ::= { nbsSffDiagsEntry 61 }

nbsSffDiagsPowerLevelOpState OBJECT-TYPE
    SYNTAX      INTEGER {
        off        (1),
        on         (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Reserved for SFF-8431 Power Level (maximum power dissipation)
          status.Value of zero indicates Power Level 1 operation
         (1.0 Watt max) Value of one indicates Power Level 2 operation
         (1.5 Watt max).Refer to Table 3.7 for Power Level declaration.
         Refer to Table 3.11 for timing."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.18a of A2h"

    ::= { nbsSffDiagsEntry 62 }

nbsSffDiagsSoftRSSelect OBJECT-TYPE
    SYNTAX      INTEGER {
        off        (1),
        on         (2)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "Read/write bit that allows software Tx rate control. Writing
          1 selects full speed Tx operation. This bit is OR d with the
          hard RS(1) pin value.See Table 3.11 for timing requirements.
          Default at power up is logic zero/low. If Soft RS(1) is not
          implemented, the transceiver ignores the value of this bit.
          Note: Specific transceiver behaviors of this bit are
          identified in Table 3.6a and referenced documents. See
          Table 3.17, byte 110, bit 3 for Soft RS(0) Select."
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.18a of A2h"

    ::= { nbsSffDiagsEntry 63 }


--
-- the MSA Extensions table
--

nbsSffMsxTableSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "The number of entries in nbsSffMsxTable"
        ::= { nbsSffMsxGrp 1 }

nbsSffMsxTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF NbsSffMsxEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Non-standardized extensions to the Multi-Source Agreement"
    ::= { nbsSffMsxGrp 2 }

nbsSffMsxEntry      OBJECT-TYPE
    SYNTAX  NbsSffMsxEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Pluggable Transceiver information and settings yet to be
         standardized"
    INDEX { nbsSffMsxPhysicalIfIndex }
    ::= { nbsSffMsxTable 1 }

NbsSffMsxEntry ::= SEQUENCE {
    nbsSffMsxPhysicalIfIndex   InterfaceIndex,
    nbsSffMsxHasSgmiiPhy       INTEGER
}

nbsSffMsxPhysicalIfIndex  OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "MIB2 ifIndex of this port"
    ::= { nbsSffMsxEntry 1 }

nbsSffMsxHasSgmiiPhy OBJECT-TYPE
    SYNTAX      INTEGER {
        notSupported (1),
        no           (2),
        yes          (3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Some Gigabit Ethernet compatible SFP transeivers, such as
         SFP-FDSGMII-M and SFP-FDSGMII-LR, have a built-in SGMII PHY.
         Those that do require special autonegotiation processing,
         without which autonegotiation will fail and the port will be
         unable to pass traffic.

         If the SFP has a built-in SGMII PHY, the user should set this
         to yes(3)."
    DEFVAL { no }
    ::= { nbsSffMsxEntry 2 }

END