-- Box Services MIB overview:
-- Box Services MIB falls under ng7000managedswitch MIB node of the private subtree.

NETGEAR-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN

-- Netgear Inc NETGEAR Box Services MIB
-- Copyright Netgear Inc(2004-2008) All rights reserved.

-- This SNMP Management Information Specification
-- embodies Netgear Inc's confidential and proprietary
-- intellectual property.  Netgear Inc retains all title
-- and ownership in the Specification including any revisions.

-- This Specification is supplied "AS IS", Netgear Inc
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    Unsigned32, Integer32               FROM SNMPv2-SMI
    TEXTUAL-CONVENTION                         FROM SNMPv2-TC
    DisplayString                            FROM RFC1213-MIB
    ng7000managedswitch                            FROM NETGEAR-REF-MIB;

    fastPathBoxServices MODULE-IDENTITY
           LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
           ORGANIZATION "Netgear Inc"
           CONTACT-INFO ""
 
     DESCRIPTION
          "The Netgear Private MIB for NETGEAR Box Services Feature."

      -- Revision history.
      REVISION
          "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
      DESCRIPTION
          "Postal address updated."
      REVISION
          "200802220000Z" -- 22 Feb 2008 12:00:00 GMT
      DESCRIPTION
          "Netgear branding related changes."

      ::= { ng7000managedswitch 43 }

BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
   STATUS  current
   DESCRIPTION
           "The temperature state"
   SYNTAX      INTEGER {
                        low(0),
                        normal(1),
                        warning(2),
                        critical(3),
                        shutdown(4),
                        notpresent(5),
                        notoperational(6)
                       }

--**************************************************************************************
--    boxServicesGroup
--
--    This group provides configuration and status of the Box Services
--    feature.  
--
--**************************************************************************************

    boxServicesGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
  
   --**************************************************************************************
   -- Some scalars
   
    boxServicesNormalTempRangeMin OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Lower boundary of normal temperature range."
      DEFVAL { 0 }
    ::= { boxServicesGroup 1 }

    boxServicesNormalTempRangeMax OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Upper boundary of normal temperature range."
      DEFVAL { 45 }
    ::= { boxServicesGroup 2 }

    boxServicesTemperatureTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
      DEFVAL { enable }
    ::= { boxServicesGroup 3 }

    boxServicesPSMStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Power Supply Module state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 4 }
    
    boxServicesFanStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Fan state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 5 }



    boxServicesThermalShutdownSensor         OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The number of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 13 }

    boxServicesThermalShutdownTemperature    OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The temperature of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 14 }

   --**************************************************************************************
   -- boxServicesFans

    boxServicesFansTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Fan"
         ::= { boxServicesGroup 6 }

    boxServicesFansEntry OBJECT-TYPE
         SYNTAX      BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Fan Entry"
         INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
         ::= { boxServicesFansTable 1 }

    BoxServicesFansEntry ::= SEQUENCE {
          boxServicesFanUnitIndex
              Unsigned32,
      boxServicesFansIndex
              Integer32,
          boxServicesFanItemType
              INTEGER,
          boxServicesFanItemState
              INTEGER,
          boxServicesFanSpeed
              OCTET STRING,
          boxServicesFanDutyLevel
              OCTET STRING
          }

    boxServicesFanUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unit index for an entry in the Box Services Fan Table"
         ::= { boxServicesFansEntry 6 }

    boxServicesFansIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of fan table entry"
         ::= { boxServicesFansEntry 1 }

    boxServicesFanItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of fan"
         ::= { boxServicesFansEntry 2 }


    boxServicesFanItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  powering(4),
                                  nopower(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
         ::= { boxServicesFansEntry 3 }


      boxServicesFanSpeed OBJECT-TYPE
             SYNTAX      OCTET STRING (SIZE (13))
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The speed of fan"
         ::= { boxServicesFansEntry 4}
         
      boxServicesFanDutyLevel OBJECT-TYPE
             SYNTAX      OCTET STRING (SIZE (13))
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The duty level of fan, in percents"
         ::= { boxServicesFansEntry 5}


   --**************************************************************************************
   -- boxServicesPowSupplies

    boxServicesPowSuppliesTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Power supply"
         ::= { boxServicesGroup 7 }

    boxServicesPowSuppliesEntry OBJECT-TYPE
         SYNTAX      BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Power Supply Entry"
         INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
         ::= { boxServicesPowSuppliesTable 1 }

    BoxServicesPowSuppliesEntry ::= SEQUENCE {
          boxServicesPowerSuppUnitIndex
              Unsigned32,
      boxServicesPowSupplyIndex
              Integer32,
          boxServicesPowSupplyItemType
              INTEGER,
          boxServicesPowSupplyItemState
              INTEGER
          }

    boxServicesPowerSuppUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unit index for an entry in the Box Services Power Supply Table"
         ::= { boxServicesPowSuppliesEntry 4 }

    boxServicesPowSupplyIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of power supply table entry"
         ::= { boxServicesPowSuppliesEntry 1 }

    boxServicesPowSupplyItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6) 
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of power supply"
         ::= { boxServicesPowSuppliesEntry 2 }


    boxServicesPowSupplyItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  powering(4),
                                  nopower(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
                                                  incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
         ::= { boxServicesPowSuppliesEntry 3 }


         
   --**************************************************************************************
   -- boxServicesTempSensors


    boxServicesTempSensorsTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Temperature sensor"
         ::= { boxServicesGroup 8 }


    boxServicesTempSensorsEntry OBJECT-TYPE
         SYNTAX      BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Temperature Sensor Entry"
         INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
         ::= { boxServicesTempSensorsTable 1 }

    BoxServicesTempSensorsEntry ::= SEQUENCE {
          boxServicesUnitIndex
              Unsigned32,
          boxServicesTempSensorIndex
              Unsigned32,
          boxServicesTempSensorType
              INTEGER,
          boxServicesTempSensorState
              BoxsTemperatureStatus,
          boxServicesTempSensorTemperature
              Integer32
          }
    
    boxServicesUnitIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Unit index for an entry in the Box Services Temperature Sensor Table"
         ::= { boxServicesTempSensorsEntry 1 }

    boxServicesTempSensorIndex OBJECT-TYPE
         SYNTAX      Unsigned32
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of temperature sensor table entry"
         ::= { boxServicesTempSensorsEntry 2 }


    boxServicesTempSensorType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of temperature sensor"
         ::= { boxServicesTempSensorsEntry 3 }


    boxServicesTempSensorState OBJECT-TYPE
         SYNTAX      BoxsTemperatureStatus 
         MAX-ACCESS  read-only
         STATUS      obsolete
         DESCRIPTION
                     "The state of temperature sensor"
         ::= { boxServicesTempSensorsEntry 4 }


      boxServicesTempSensorTemperature OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The temperature value reported by sensor"
         ::= { boxServicesTempSensorsEntry 5 }

    boxServicesTempUnitTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Temperature status table"
        ::= { boxServicesGroup 15 }

    boxServicesTempUnitEntry OBJECT-TYPE
        SYNTAX      BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Box Services Temperature Unit Entry"
        INDEX { boxServicesTempUnitIndex }
        ::= { boxServicesTempUnitTable 1 }

    BoxServicesTempUnitEntry ::= SEQUENCE {
        boxServicesTempUnitIndex
           Unsigned32,
        boxServicesTempUnitState
           BoxsTemperatureStatus,
        boxServicesTempUnitTemperature
           Integer32
        }

    boxServicesTempUnitIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only 
        STATUS      current
        DESCRIPTION
            "Unit index for an entry in the Box Services Temperature Unit Table"
        ::= { boxServicesTempUnitEntry 1 }

    boxServicesTempUnitState OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature state of the unit"
        ::= { boxServicesTempUnitEntry 2 }

    boxServicesTempUnitTemperature OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The highest temperature currently reported by any sensor on the unit"
        ::= { boxServicesTempUnitEntry 3 }

--**************************************************************************************
--    boxServicesNotificationsGroup
--
--    This group provides notification definitions for the Box Services
--    feature.  
--
--**************************************************************************************

    boxServicesNotificationsGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }

   --**************************************************************************************
   -- boxServices notification definitions

      boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
         losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions
             losepower          - a power supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

      boxsTemperatureChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             abovethreshold(1),
             belowthreshold(2),
             withinnormalrange(3)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes change of the temperature. 
           To avoid flipping on boundary conditions, it is allowed to send the trap 
           taking into account some margin around thresholds.
           
             abovethreshold     - temperature increased and crossed upper threshold value
             belowthreshold     - temperature decreased and crossed lower threshold value
             withinnormalrange  - temperature returned to normal range (between threshold)"
        ::= { boxServicesNotificationsGroup 2 }

    boxsTemperatureStatusCurrentEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the current status of a switch."
        ::= { boxServicesNotificationsGroup 3 }

    boxsTemperatureStatusPreviousEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the previous status of a switch."
        ::= { boxServicesNotificationsGroup 4 }



--**************************************************************************************
--   Traps
--**************************************************************************************

     fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }



     boxsFanStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesFansIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when fan state change happens."
         ::= { fastPathBoxServicesTraps 1 }

     boxsPowSupplyStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesPowSupplyIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when power supply state change happens."
         ::= { fastPathBoxServicesTraps 2 }


     boxsTemperatureChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesTempSensorIndex,
                      boxsTemperatureChangeEvent
                 }
         STATUS             obsolete
         DESCRIPTION
             "Trap is sent when temperature is changing and crossing any of the thresholds"
         ::= { fastPathBoxServicesTraps 3 }


     boxsThermalShutdown NOTIFICATION-TYPE
         OBJECTS {
                   boxServicesThermalShutdownSensor,
                   boxServicesThermalShutdownTemperature
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when thermal shutdown is initiated."
         ::= { fastPathBoxServicesTraps 4 }


    boxsTemperatureStateChange NOTIFICATION-TYPE
        OBJECTS {
                     boxServicesTempUnitIndex,
                     boxsTemperatureStatusCurrentEvent,
                     boxsTemperatureStatusPreviousEvent
                }
        STATUS             current
        DESCRIPTION
            "Trap is sent when the system temperature crosses a threshold. 
            To avoid rapid flapping between states, a hysteresis may
            be applied."
        ::= { fastPathBoxServicesTraps 5 }

--**************************************************************************************
--    Locator LED manage group
--
--    This group provides manage definitions for the Locator LED feature.  
--
--**************************************************************************************

    boxsLocatorLedConfigGroup                 OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }

    boxsLocatorLedUnit OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Spesifies unit number where Locator LED should blink on.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
          ::= { boxsLocatorLedConfigGroup 1 }

    boxsLocatorLedTime OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Indicates time period in seconds for Locator LED blinking.
                      The range is from 20 to 3600 seconds.
                      The dafault value is 20 seconds.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         DEFVAL { 20 }
          ::= { boxsLocatorLedConfigGroup 2 }

    boxsLocatorLedEnable OBJECT-TYPE
         SYNTAX      INTEGER {
                       disable(0), 
                       enable(1)
                     }
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Starts the Locator LED blinking.
                      If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
                      If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         ::= { boxsLocatorLedConfigGroup 3 }

END