TIMETRA-LOG-MIB DEFINITIONS ::= BEGIN

IMPORTS
    InetAddress, InetAddressType
                                                         FROM INET-ADDRESS-MIB
    SnmpAdminString,
    SnmpMessageProcessingModel,
    SnmpSecurityLevel
                                                         FROM SNMP-FRAMEWORK-MIB
    snmpNotifyEntry
                                                         FROM SNMP-NOTIFICATION-MIB
    MODULE-COMPLIANCE, NOTIFICATION-GROUP,
    OBJECT-GROUP
                                                         FROM SNMPv2-CONF
    sysDescr, sysObjectID
                                                         FROM SNMPv2-MIB
    Counter32, Counter64, Integer32,
    IpAddress, MODULE-IDENTITY,
    NOTIFICATION-TYPE, OBJECT-TYPE,
    Unsigned32
                                                         FROM SNMPv2-SMI
    DateAndTime, DisplayString, RowStatus,
    StorageType, TEXTUAL-CONVENTION,
    TimeStamp, TruthValue
                                                         FROM SNMPv2-TC
    TFilterAction, TFilterActionOrDefault
                                                         FROM TIMETRA-FILTER-MIB
    timetraSRMIBModules, tmnxSRConfs,
    tmnxSRNotifyPrefix, tmnxSRObjs
                                                         FROM TIMETRA-GLOBAL-MIB
    THsmdaCounterIdOrZero,
    THsmdaCounterIdOrZeroOrAll,
    TItemDescription, TLNamedItemOrEmpty,
    TNamedItem, TNamedItemOrEmpty, TQueueId,
    TQueueIdOrAll, TmnxAccPlcyAACounters,
    TmnxAccPlcyAASubAttributes,
    TmnxAccPlcyOECounters,
    TmnxAccPlcyOICounters,
    TmnxAccPlcyPolicerECounters,
    TmnxAccPlcyPolicerICounters,
    TmnxAccPlcyQECounters,
    TmnxAccPlcyQICounters, TmnxActionType,
    TmnxAdminState, TmnxOperState,
    TmnxSyslogFacility, TmnxSyslogSeverity,
    TmnxUdpPort
                                                         FROM TIMETRA-TC-MIB
    ;

timetraLogMIBModule              MODULE-IDENTITY
    LAST-UPDATED "202007140000Z"
    ORGANIZATION "Nokia"
    CONTACT-INFO
        "Nokia SROS Support
         Web: http://www.nokia.com"
    DESCRIPTION
        "This document is the SNMP MIB module to manage and provision the Nokia
         SROS Logging utility.

         Copyright 2003-2020 Nokia.  All rights reserved.
         Reproduction of this document is authorized on the condition that
         the foregoing copyright notice is included.

         This SNMP MIB module (Specification) embodies Nokia's
         proprietary intellectual property.  Nokia retains
         all title and ownership in the Specification, including any
         revisions.

         Nokia grants all interested parties a non-exclusive license to use and
         distribute an unmodified copy of this Specification in connection with
         management of Nokia products, and without fee, provided this copyright
         notice and license appear on all copies.

         This Specification is supplied 'as is', and Nokia makes no warranty,
         either express or implied, as to the use, operation, condition, or
         performance of the Specification."

    REVISION    "202007140000Z"
    DESCRIPTION
        "Rev 20               14 Jul 2020 00:00
         Release 20 of the TIMETRA-LOG-MIB."

    REVISION    "201904010000Z"
    DESCRIPTION
        "Rev 19               1 April 2019 00:00
         Release 19 of the TIMETRA-LOG-MIB."

    REVISION    "201706300000Z"
    DESCRIPTION
        "Rev 15.1               30 Jun 2017 00:00
         15.1 release of the TIMETRA-LOG-MIB."

    REVISION    "201703010000Z"
    DESCRIPTION
        "Rev 15.0               01 Mar 2017 00:00
         15.0 release of the TIMETRA-LOG-MIB."

    REVISION    "201601010000Z"
    DESCRIPTION
        "Rev 14.0               01 Jan 2016 00:00
         14.0 release of the TIMETRA-LOG-MIB."

    REVISION    "201501010000Z"
    DESCRIPTION
        "Rev 13.0               01 Jan 2015 00:00
         13.0 release of the TIMETRA-LOG-MIB."

    REVISION    "201401010000Z"
    DESCRIPTION
        "Rev 12.0               01 Jan 2014 00:00
         12.0 release of the TIMETRA-LOG-MIB."

    REVISION    "201102010000Z"
    DESCRIPTION
        "Rev 9.0                01 Feb 2011 00:00
         9.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200902280000Z"
    DESCRIPTION
        "Rev 7.0                28 Feb 2009 00:00
         7.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200801010000Z"
    DESCRIPTION
        "Rev 6.0                01 Jan 2008 00:00
         6.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200701010000Z"
    DESCRIPTION
        "Rev 5.0                01 Jan 2007 00:00
         5.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200603150000Z"
    DESCRIPTION
        "Rev 4.0                15 Mar 2006 00:00
         4.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200501240000Z"
    DESCRIPTION
        "Rev 2.1                24 Jan 2005 00:00
         2.1 release of the TIMETRA-LOG-MIB."

    REVISION    "200405270000Z"
    DESCRIPTION
        "Rev 2.1                27 May 2004 00:00
         2.1 release of the TIMETRA-LOG-MIB."

    REVISION    "200401150000Z"
    DESCRIPTION
        "Rev 2.0                15 Jan 2004 00:00
         2.0 release of the TIMETRA-LOG-MIB."

    REVISION    "200308150000Z"
    DESCRIPTION
        "Rev 1.2                15 Aug 2003 00:00
         1.2 release of the TIMETRA-LOG-MIB."

    REVISION    "200301200000Z"
    DESCRIPTION
        "Rev 1.0                20 Jan 2003 00:00
         1.0 Release of the TIMETRA-LOG-MIB."

    REVISION    "200111100000Z"
    DESCRIPTION
        "Rev 0.1                10 Nov 2001 00:00
         Initial version of the TIMETRA-LOG-MIB."

    ::= { timetraSRMIBModules 12 }

TmnxPerceivedSeverity            ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "ITU perceived severity values as per M.3100 and X.733"
    SYNTAX      INTEGER {
        none          (0),
        cleared       (1),
        indeterminate (2),
        critical      (3),
        major         (4),
        minor         (5),
        warning       (6)
    }

TmnxSyslogId                     ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxSyslogId uniquely identifies an entry in the
         tmnxSyslogTargetTable to be used for the syslog collector target
         information when creating a log file where tmnxLogIdDestination has a
         value of 'syslog (2)'."
    SYNTAX      Integer32 (1..40)

TmnxSyslogIdOrEmpty              ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxSyslogIdOrEmpty uniquely identifies an entry in the
         tmnxSyslogTargetTable to be used for the syslog collector target
         information when creating a log file where tmnxLogIdDestination
         has a value of 'syslog (2)'.  The value of 0 is used when no
         entry exists in the tmnxSyslogTargetTable."
    SYNTAX      Integer32 (0 | 1..40)

TmnxLogFileId                    ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxLogFileId uniquely identifies a file-id to be
         used when creating a log or accounting file.  A value of zero (0)
         indicates none specified and is invalid when used as an index
         for the tmnxLogFileIdTable."
    SYNTAX      Integer32 (0..99)

TmnxLogFileType                  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxLogFileType indicates the type of information that
         will be written to this file."
    SYNTAX      INTEGER {
        none             (0),
        eventLog         (1),
        accountingPolicy (2)
    }

TmnxLogIdIndex                   ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdIndex uniquely identifies an event stream log.
         Note that 3 default TmnxLogIdEntry rows are created by the agent using
         TmnxLogIdIndex values 99, 100 and 101."
    SYNTAX      Integer32 (1..101)

TmnxStgIndex                     ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxStgIndex uniquely identifies an event stream log. It
         is the same as an TmnxLogIdIndex but with a limited range."
    SYNTAX      Integer32 (1..100)

TmnxCFlash                       ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxCFlash uniquely identifies a compact flash
         module on the active CPM card.  A value of zero (0) indicates
         none specified."
    SYNTAX      Unsigned32

TmnxLogFilterId                  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxLogFilterId is the identification number of an
         event log filter.  The value of zero indicates none specified.
         The value of zero (0) is invalid when used as an index for the
         tmnxLogFilterTable. Filter entry 1001 is created by the agent."
    SYNTAX      Unsigned32 (0..1500)

TmnxLogFilterEntryId             ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxLogFilterEntryId is the identification number of an
         event log filter entry."
    SYNTAX      Unsigned32 (1..999)

TmnxLogFilterOperator            ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "When TmnxLogFilterOperator has a value of 'off', the item is not
         matched.  Otherwise the value of TmnxLogFilterOperator determines
         the comparison operator to be used as the parameter match criterion."
    SYNTAX      INTEGER {
        off                (1),
        equal              (2),
        notEqual           (3),
        lessThan           (4),
        lessThanOrEqual    (5),
        greaterThan        (6),
        greaterThanOrEqual (7)
    }

TmnxEventNumber                  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Each log event type has a unique identifying number.  This number is
         unique within a particular software application, such as IP, MPLS,
         OSPF, etc.; but it is not necessarily unique across different software
         applications.  That is MPLS event #1001 may be different from OSPF
         event #1001."
    SYNTAX      Unsigned32

TmnxLogExRbkOperationType        ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The value of TmnxLogExRbkOperationType specifies the type of operation
         being performed."
    SYNTAX      INTEGER {
        unknown  (0),
        exec     (1),
        rollback (2),
        vsd      (3),
        load     (4)
    }

LogStorageType                   ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        ""
    SYNTAX      StorageType

tmnxLogObjs                      OBJECT IDENTIFIER ::= { tmnxSRObjs 12 }

tmnxLogNotificationObjects       OBJECT IDENTIFIER ::= { tmnxLogObjs 1 }

tmnxLogFileDeletedLogId          OBJECT-TYPE
    SYNTAX      TmnxLogIdIndex
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedLogId indicates with which event log-id
         or accounting-policy-id the deleted file was associated. Note the
         corresponding entry in the tmnxLogIdTable or tmnxLogApTable may no
         longer exist."
    ::= { tmnxLogNotificationObjects 1 }

tmnxLogFileDeletedFileId         OBJECT-TYPE
    SYNTAX      TmnxLogFileId
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedFileId indicates with which event
         log-id or accounting-policy-id the deleted file was associated. Note
         that the corresponding entry in the tmnxLogFileIdTable may no longer
         exist."
    ::= { tmnxLogNotificationObjects 2 }

tmnxLogFileDeletedLogType        OBJECT-TYPE
    SYNTAX      TmnxLogFileType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedLogType indicates whether the deleted
         file was an 'eventLog' or 'accountingPolicy'."
    ::= { tmnxLogNotificationObjects 3 }

tmnxLogFileDeletedLocation       OBJECT-TYPE
    SYNTAX      TmnxCFlash
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedLocation indicates on which compact
         flash device the event log or accounting policy file that has been
         deleted was located. "
    ::= { tmnxLogNotificationObjects 4 }

tmnxLogFileDeletedName           OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedName indicates the pathname of an event
         log or accounting policy file that has been deleted because of space
         contention on a compact flash device."
    ::= { tmnxLogNotificationObjects 5 }

tmnxLogFileDeletedCreateTime     OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileDeletedCreateTime indicates the date and time
         when the deleted file had been created."
    ::= { tmnxLogNotificationObjects 6 }

tmnxLogTraceErrorTitle           OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..50))
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogTraceErrorTitle indicates the title string of the
         trace error event that generated the tmnxLogTraceError notification."
    ::= { tmnxLogNotificationObjects 7 }

tmnxLogTraceErrorSubject         OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..50))
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogTraceErrorSubject indicates the subject string of
         the trace error event that generated the tmnxLogTraceError
         notification.

         The subject is the entity that originated the event, such as the Slot
         ID."
    ::= { tmnxLogNotificationObjects 8 }

tmnxLogTraceErrorMessage         OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogTraceErrorMessage indicates the message text
         string of the trace error event that generated the tmnxLogTraceError
         notification."
    ::= { tmnxLogNotificationObjects 9 }

tmnxLogThrottledEventID          OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "tmnxLogThrottledEventID is used by the tmnxLogEventThrottled
         notification to indicate the NOTIFICATION-TYPE object identifier of
         the throttled event."
    ::= { tmnxLogNotificationObjects 10 }

tmnxLogThrottledEvents           OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "tmnxLogThrottledEvents is used by the tmnxLogEventThrottled
         notification to indicate the number of events dropped because of event
         throttling during the last throttle interval."
    ::= { tmnxLogNotificationObjects 11 }

tmnxSysLogTargetId               OBJECT-TYPE
    SYNTAX      TmnxSyslogId
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "tmnxSysLogTargetId is used by the tmnxSysLogTargetProblem notification
         to indicate the involved TmnxSyslogId."
    ::= { tmnxLogNotificationObjects 12 }

tmnxSysLogTargetProblemDescr     OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxSysLogTargetProblemDescr indicates the type of error
         encountered when trying to deliver events to the destination specified
         in the TmnxSyslogId."
    ::= { tmnxLogNotificationObjects 13 }

tmnxLogNotifyApInterval          OBJECT-TYPE
    SYNTAX      Integer32 (5..120)
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogNotifyApInterval indicates how frequently the
         statistics are collected and written to their destination."
    ::= { tmnxLogNotificationObjects 14 }

tmnxStdReplayStartEvent          OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdReplayStartEvent indicates the SNMP notification
         request ID of the first missed event that was replayed when an SNMP
         notification target address was readded to the RTM following a period
         when the target address had been removed. It is used by the
         tmnxStdEventsReplayed notification."
    ::= { tmnxLogNotificationObjects 15 }

tmnxStdReplayEndEvent            OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdReplayEndEvent indicates the SNMP notification
         request ID of the last missed event that was replayed when an SNMP
         notification target address was readded to the RTM following a period
         when the target address had been removed. It is used by the
         tmnxStdEventsReplayed notification."
    ::= { tmnxLogNotificationObjects 16 }

tmnxEhsHEntryMinDelayInterval    OBJECT-TYPE
    SYNTAX      Unsigned32 (1..604800)
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryMinDelayInterval indicates the difference
         between the current time and the time as mentioned in
         tmnxEhsHEntryLastExecuted."
    ::= { tmnxLogNotificationObjects 17 }

tmnxLogMaxLogs                   OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "logs"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The maximum number of concurrent active Logs that are allowed. A value
         of zero (0) for this object implies that there is no limit for the
         number of concurrent active logs in effect.

         The maximum number of logs in the Base context is restricted to 30 and
         in the VPRN context to 30."
    DEFVAL      { 60 }
    ::= { tmnxLogObjs 2 }

tmnxLogFileIdTable               OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogFileIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines the Nokia SROS series Log File ID Table for providing, via
         SNMP, the capability of defining the characteristics for log and
         accounting files and associating them with a file-id. The actual file
         is not created until the file-id is used in a log or accounting file
         configuration."
    ::= { tmnxLogObjs 3 }

tmnxLogFileIdEntry               OBJECT-TYPE
    SYNTAX      TmnxLogFileIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the tmnxLogFileIdTable.  Entries are created
         and deleted in this table by SNMP sets to tmnxLogFileIdRowStatus."
    INDEX       { tmnxLogFileId }
    ::= { tmnxLogFileIdTable 1 }

TmnxLogFileIdEntry               ::= SEQUENCE
{
    tmnxLogFileId                    TmnxLogFileId,
    tmnxLogFileIdRowStatus           RowStatus,
    tmnxLogFileIdStorageType         StorageType,
    tmnxLogFileIdRolloverTime        Integer32,
    tmnxLogFileIdRetainTime          Integer32,
    tmnxLogFileIdAdminLocation       TmnxCFlash,
    tmnxLogFileIdOperLocation        TmnxCFlash,
    tmnxLogFileIdDescription         TItemDescription,
    tmnxLogFileIdLogType             TmnxLogFileType,
    tmnxLogFileIdLogId               Integer32,
    tmnxLogFileIdPathName            DisplayString,
    tmnxLogFileIdCreateTime          DateAndTime,
    tmnxLogFileIdBackupLoc           TmnxCFlash,
    tmnxLogFileIdName                TLNamedItemOrEmpty
}

tmnxLogFileId                    OBJECT-TYPE
    SYNTAX      TmnxLogFileId
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index value tmnxLogFileId uniquely identifies a file-id to be used
         when creating a log or accounting file."
    ::= { tmnxLogFileIdEntry 1 }

tmnxLogFileIdRowStatus           OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object allows entries to be created and deleted
         in the tmnxLogFileIdTable.  Deletion of an entry in this
         table will not succeed if it is currently used by any log
         or accounting file."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxLogFileIdEntry 2 }

tmnxLogFileIdStorageType         OBJECT-TYPE
    SYNTAX      StorageType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The storage type for this conceptual row. Conceptual rows having the
         value 'permanent' need not allow write access to any columnar objects
         in the row."
    DEFVAL      { nonVolatile }
    ::= { tmnxLogFileIdEntry 3 }

tmnxLogFileIdRolloverTime        OBJECT-TYPE
    SYNTAX      Integer32 (5..10080)
    UNITS       "minutes"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdRolloverTime specifies how often, in
         minutes, a new log or accounting file will be created.  If the value
         of tmnxLogFileIdLogType is not 'rollover', then the value of this
         object is irrelevant."
    DEFVAL      { 1440 }
    ::= { tmnxLogFileIdEntry 4 }

tmnxLogFileIdRetainTime          OBJECT-TYPE
    SYNTAX      Integer32 (1..500)
    UNITS       "hours"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdRetainTime specifies the minimum time,
         in hours, that a file is retained on the media.  Once this time
         period has expired the file is deleted."
    DEFVAL      { 12 }
    ::= { tmnxLogFileIdEntry 5 }

tmnxLogFileIdAdminLocation       OBJECT-TYPE
    SYNTAX      TmnxCFlash
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdAdminLocation specifies where the log
         or accounting file should be created.  The file location should be a
         compact flash on the primary CPM.  When the secondary CPM becomes
         the primary CPM after a failure, the same log file policies will
         be activated.  Thus it is recommended that the same media is
         available to both secondary and primary CPMs.

         If no location is specified, 0, the compact flash cf1: is used to
         store the log files or cf2: is used to store accounting files."
    DEFVAL      { 0 }
    ::= { tmnxLogFileIdEntry 6 }

tmnxLogFileIdOperLocation        OBJECT-TYPE
    SYNTAX      TmnxCFlash
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdOperLocation indicates where the log
         or accounting file has been created.  The file location should be a
         compact flash on the primary CPM.  When the secondary CPM becomes
         the primary CPM after a failure, the same log file policies will
         be activated.  Thus it is recommended that the same media is
         available to both secondary and primary CPMs."
    ::= { tmnxLogFileIdEntry 7 }

tmnxLogFileIdDescription         OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdDescription is a user provided description
         string for this log file-id entry.  It can consist of any printable,
         seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''h }
    ::= { tmnxLogFileIdEntry 8 }

tmnxLogFileIdLogType             OBJECT-TYPE
    SYNTAX      TmnxLogFileType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdLogType indicates the type of information
         that will be written to this file."
    ::= { tmnxLogFileIdEntry 9 }

tmnxLogFileIdLogId               OBJECT-TYPE
    SYNTAX      Integer32 (0..99)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdLogId indicates the ID index of the log or
         accounting policy this file is attached to.  A value of zero (0)
         indicates that this file definition is not currently used by any
         log or accounting policy."
    ::= { tmnxLogFileIdEntry 10 }

tmnxLogFileIdPathName            OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdPathName is the pathname of the currently
         opened file used by this file-id entry. The value of
         tmnxLogFileIdPathName is affected by the value of stiPreferLocalTime."
    ::= { tmnxLogFileIdEntry 11 }

tmnxLogFileIdCreateTime          OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdCreateTime is the time the currently opened
         file version used by this file-id entry was created. The value of
         tmnxLogFileIdCreateTime is affected by the value of
         stiPreferLocalTime."
    ::= { tmnxLogFileIdEntry 12 }

tmnxLogFileIdBackupLoc           OBJECT-TYPE
    SYNTAX      TmnxCFlash
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdBackupLoc specifies where the log
         or accounting file should be created if it cannot be created in
         the location specified by tmnxLogFileIdAdminLocation.  The file
         location should be a compact flash on the primary CPM.  When the
         secondary CPM becomes the primary CPM after a failure, the same
         log file policies will be activated.  Thus it is recommended that
         the same media is available to both secondary and primary CPMs.

         If no backup location is specified, 0, and the log or accounting file
         could not be created in the location specified by
         tmnxLogFileIdAdminLocation or the file creation at the specified
         backup location fails, a file create failure trap is issued and the
         associated log or accounting policy is marked as operationally
         'outOfService'."
    DEFVAL      { 0 }
    ::= { tmnxLogFileIdEntry 13 }

tmnxLogFileIdName                OBJECT-TYPE
    SYNTAX      TLNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFileIdName specifies particular entry in the
         tmnxLogFileIdTable."
    DEFVAL      { "" }
    ::= { tmnxLogFileIdEntry 14 }

tmnxLogApTable                   OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogApEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series Log Accounting Policy Table contains an entry
         for each accounting policy that specifies the characteristics of the
         accounting records associated with an accounting policy."
    ::= { tmnxLogObjs 4 }

tmnxLogApEntry                   OBJECT-TYPE
    SYNTAX      TmnxLogApEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the tmnxLogApTable.  Entries in the
         tmnxLogApTable are created and destroyed via SNMP Set
         requests to tmnxLogApRowStatus."
    INDEX       { tmnxLogApPolicyId }
    ::= { tmnxLogApTable 1 }

TmnxLogApEntry                   ::= SEQUENCE
{
    tmnxLogApPolicyId                Integer32,
    tmnxLogApRowStatus               RowStatus,
    tmnxLogApStorageType             LogStorageType,
    tmnxLogApAdminStatus             TmnxAdminState,
    tmnxLogApOperStatus              TmnxOperState,
    tmnxLogApInterval                Integer32,
    tmnxLogApDescription             TItemDescription,
    tmnxLogApDefault                 TruthValue,
    tmnxLogApRecord                  INTEGER,
    tmnxLogApToFileId                TmnxLogFileId,
    tmnxLogApPortType                INTEGER,
    tmnxLogApDefaultInterval         TruthValue,
    tmnxLogApDataLossCount           Counter32,
    tmnxLogApLastDataLossTimeStamp   TimeStamp,
    tmnxLogApToFileType              INTEGER,
    tmnxLogApIncludeSystemInfo       TruthValue,
    tmnxLogApAlign                   TruthValue
}

tmnxLogApPolicyId                OBJECT-TYPE
    SYNTAX      Integer32 (1..99)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApPolicyId uniquely identifies an accounting
         policy to be used for creating accounting records.  A specific
         accounting policy can be applied to one or more service access
         points (SAPs).  Any changes made to an existing policy is applied
         immediately to all SAPs where this policy is applied."
    ::= { tmnxLogApEntry 1 }

tmnxLogApRowStatus               OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object allows entries to be created and deleted
         in the tmnxLogApTable.  Deletion of an entry in this
         table will not succeed if it is currently applied to any
         service access point (SAP)."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxLogApEntry 2 }

tmnxLogApStorageType             OBJECT-TYPE
    SYNTAX      LogStorageType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The storage type for this conceptual row. Conceptual rows having the
         value 'permanent' need not allow write access to any columnar objects
         in the row."
    DEFVAL      { nonVolatile }
    ::= { tmnxLogApEntry 3 }

tmnxLogApAdminStatus             OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApAdminStatus specifies the desired administrative
         state for this accounting policy."
    DEFVAL      { outOfService }
    ::= { tmnxLogApEntry 4 }

tmnxLogApOperStatus              OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApOperStatus indicates the current operational
         status of this accounting policy."
    ::= { tmnxLogApEntry 5 }

tmnxLogApInterval                OBJECT-TYPE
    SYNTAX      Integer32 (1..120)
    UNITS       "minutes"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApInterval determines how frequently the
         statistics are collected and written to their destination.

         If no record is specified, default value for tmnxLogApInterval is 5
         minutes. For service and network types of record, default values are 5
         minutes and 15 minutes respectively.

         For an accounting policy with one of the following record type
         (i.e. tmnxLogApRecord) values, the minimum interval is one minute:
             completeOamPm(56),
             completeSvcActivTestHead(76),
             saa(32).

         Otherwise the minimum interval is five minutes."
    DEFVAL      { 5 }
    ::= { tmnxLogApEntry 6 }

tmnxLogApDescription             OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApDescription is a user provided description
         string for this accounting policy.  It can consist of any printable,
         seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''h }
    ::= { tmnxLogApEntry 7 }

tmnxLogApDefault                 OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "When tmnxLogApDefault has a value of 'true', it specifies that
         this accounting policy is applied to all service access points (SAPs)
         that do not have an explicit accounting policy applied.  If no
         accounting policy is associated with a SAP accounting records are
         produced in accordance with the default policy.

         Only one accounting policy entry in the tmnxLogApTable can have
         tmnxLogApDefault set to 'true'.  If there is no entry in the
         tmnxLogApTable with tmnxLogApDefault set to 'true', then the
         only accounting records collected are those explicitly configured
         accounting policies."
    DEFVAL      { false }
    ::= { tmnxLogApEntry 8 }

tmnxLogApRecord                  OBJECT-TYPE
    SYNTAX      INTEGER {
        none                        (0),
        svcIngressOctet             (1),
        svcEgressOctet              (2),
        svcIngressPkt               (3),
        svcEgressPkt                (4),
        netIngressOctet             (5),
        netEgressOctet              (6),
        netIngressPkt               (7),
        netEgressPkt                (8),
        compactSvcInOctet           (9),
        combinedSvcIngress          (10),
        combinedNetInEgOctet        (11),
        combinedSvcInEgOctet        (12),
        completeSvcInEg             (13),
        combinedSvcSdpInEg          (14),
        completeSvcSdpInEg          (15),
        completeSubscrIngrEgr       (16),
        bsxProtocol                 (17),
        bsxApplication              (18),
        bsxAppGroup                 (19),
        bsxSubscriberProtocol       (20),
        bsxSubscriberApplication    (21),
        bsxSubscriberAppGroup       (22),
        customRecordSubscriber      (23),
        customRecordService         (24),
        customRecordAa              (25),
        queueGroupOctets            (26),
        queueGroupPackets           (27),
        combinedQueueGroup          (28),
        combinedMplsLspIngress      (29),
        combinedMplsLspEgress       (30),
        combinedLdpLspEgress        (31),
        saa                         (32),
        video                       (33),
        kpiSystem                   (34),
        kpiBearerMgmt               (35),
        kpiBearerTraffic            (36),
        kpiRefPoint                 (37),
        kpiPathMgmt                 (38),
        kciIom3                     (39),
        kciSystem                   (40),
        kciBearerMgmt               (41),
        kciPathMgmt                 (42),
        completeKpi                 (43),
        completeKci                 (44),
        kpiBearerGroup              (45),
        kpiRefPathGroup             (46),
        kpiKciBearerMgmt            (47),
        kpiKciPathMgmt              (48),
        kpiKciSystem                (49),
        completeKpiKci              (50),
        aaPerformance               (51),
        completeEthernetPort        (52),
        extendedSvcIngrEgr          (53),
        completeNetIngrEgr          (54),
        aaPartition                 (55),
        completeOamPm               (56),
        kpiRefPtSecErrorCauseCode   (57),
        kpiBearerTrafficGtpEndpoint (58),
        kpiIpReas                   (59),
        kpiRadiusGroup              (60),
        kpiRefPtFailureCauseCode    (61),
        kpiDhcpGroup                (62),
        aaAdmitDeny                 (63),
        netIntfIngressOctet         (65),
        netIntfEgressOctet          (66),
        netIntfIngressPkt           (67),
        netIntfEgressPkt            (68),
        combinedNetIntfIngress      (69),
        combinedNetIntfEgress       (70),
        completeNetIntfIngrEgr      (71),
        accessEgressOctets          (72),
        accessEgressPackets         (73),
        combinedAccessEgress        (74),
        combinedNetworkEgress       (75),
        completeSvcActivTestHead    (76),
        combinedMplsSrteEgress      (77)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApRecord specifies the type of predefined
         accounting record type to be written to the accounting file.

         The value 'bsxSubscriberAppGroup (22)' was made obsolete in release
         7.0 and replaced by 'customRecordAa (25).'"
    DEFVAL      { none }
    ::= { tmnxLogApEntry 9 }

tmnxLogApToFileId                OBJECT-TYPE
    SYNTAX      TmnxLogFileId
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApToFileId is the index to the entry in the
         tmnxLogFileIdTable that specifies the file characteristics to be
         used for the destination of the accounting policy records collected
         by this accounting policy.  The file itself is created the first
         time this accounting policy is applied to a service access point
         (SAP).

         tmnxLogApToFileId must be set along with tmnxLogApToFileType to
         indicate whether the records will be stored in a file or not.

         When a destination file is specified, the value of the file is
         specified by tmnxLogApToFileId and the value of tmnxLogApToFileType
         should be 'fileId'.

         When the destination file is not specified, the value of
         tmnxLogApToFileId should be zero and the value of tmnxLogApToFileType
         should be 'noFile'."
    ::= { tmnxLogApEntry 10 }

tmnxLogApPortType                OBJECT-TYPE
    SYNTAX      INTEGER {
        none          (0),
        access        (1),
        network       (2),
        sdp           (3),
        subscriber    (4),
        appAssure     (5),
        qgrp          (6),
        saa           (7),
        mplsLspIngr   (8),
        mplsLspEgr    (9),
        ldpLspEgr     (10),
        video         (11),
        mobileGateway (12),
        ethernet      (13),
        oamPm         (14),
        networkIntf   (16),
        accessPort    (17),
        svcActvTest   (18),
        mplsSrteEgr   (19)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApPortType indicates the type of facility
         associated with the specified accounting policy's record type (i.e.
         tmnxLogApRecord)."
    ::= { tmnxLogApEntry 11 }

tmnxLogApDefaultInterval         OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "When tmnxLogApDefaultInterval has a value of 'true', it specifies that
         tmnxLogApInterval will have a default value.

         When tmnxLogApDefaultInterval has a value of 'false', user can set the
         value of tmnxLogApInterval manually."
    DEFVAL      { true }
    ::= { tmnxLogApEntry 12 }

tmnxLogApDataLossCount           OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApDataLossCount indicates the number of times a
         tmnxLogAccountingDataLoss trap was raised against this application
         policy."
    ::= { tmnxLogApEntry 13 }

tmnxLogApLastDataLossTimeStamp   OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApLastDataLossTimeStamp indicates the last time,
         since system startup that a tmnxLogAccountingDataLoss trap was raised
         against this application policy."
    ::= { tmnxLogApEntry 14 }

tmnxLogApToFileType              OBJECT-TYPE
    SYNTAX      INTEGER {
        fileId (0),
        noFile (1)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApToFileType specifies where records of an
         accounting policy are stored. It should be set along with
         tmnxLogApToFileId which specifies the destination file index where the
         accounting records are stored.

         When the value of tmnxLogApToFileType is 'noFile', it indicates that
         the accounting records will not to be stored in a file and the value
         of tmnxLogApToFileId should be set to zero.

         When the value of tmnxLogApToFileType is 'fileId', it indicates that
         the accounting records will be stored in a file specified by
         tmnxLogApToFileId.

         tmnxLogApOperStatus will transition to 'inService' when the
         tmnxLogApToFileType is set to 'noFile' or 'fileId'."
    DEFVAL      { fileId }
    ::= { tmnxLogApEntry 15 }

tmnxLogApIncludeSystemInfo       OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApIncludeSystemInfo specifies whether or not to
         include system information at the top of each accounting file
         generated for a given accounting policy."
    DEFVAL      { false }
    ::= { tmnxLogApEntry 16 }

tmnxLogApAlign                   OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "If true generation of accounting statistics is aligned with absolute
         time. First statistics are generated when absolute time is dividable
         by collection-interval value. After that it continues with
         collection-interval. This is important for synchronization of
         statistics interval between various nodes in network. If false,
         generation of accounting statistis is triggered right after command
         execution and continues after configured collection-interval. type
         that do not have an accounting policy."
    DEFVAL      { false }
    ::= { tmnxLogApEntry 17 }

tmnxLogIdTable                   OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series Log Identification Table contains an entry for
         each log that specifies the characteristics of that log associated
         with a log-id number."
    ::= { tmnxLogObjs 5 }

tmnxLogIdEntry                   OBJECT-TYPE
    SYNTAX      TmnxLogIdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the tmnxLogIdTable.  Entries in the
         tmnxLogIdTable are created and destroyed via SNMP Set
         requests to tmnxLogIdRowStatus.  Default log entries 99,
         and 100 are created by the agent."
    INDEX       { tmnxLogIdIndex }
    ::= { tmnxLogIdTable 1 }

TmnxLogIdEntry                   ::= SEQUENCE
{
    tmnxLogIdIndex                   TmnxLogIdIndex,
    tmnxLogIdRowStatus               RowStatus,
    tmnxLogIdStorageType             LogStorageType,
    tmnxLogIdAdminStatus             TmnxAdminState,
    tmnxLogIdOperStatus              TmnxOperState,
    tmnxLogIdDescription             TItemDescription,
    tmnxLogIdFilterId                TmnxLogFilterId,
    tmnxLogIdSource                  BITS,
    tmnxLogIdDestination             INTEGER,
    tmnxLogIdFileId                  TmnxLogFileId,
    tmnxLogIdSyslogId                TmnxSyslogIdOrEmpty,
    tmnxLogIdMaxMemorySize           Unsigned32,
    tmnxLogIdConsoleSession          TruthValue,
    tmnxLogIdForwarded               Counter64,
    tmnxLogIdDropped                 Counter64,
    tmnxLogIdTimeFormat              INTEGER,
    tmnxLogIdPythonPolicy            TNamedItemOrEmpty,
    tmnxLogIdOperDestination         INTEGER,
    tmnxLogIdNetconfStream           TNamedItemOrEmpty,
    tmnxLogIdName                    TLNamedItemOrEmpty
}

tmnxLogIdIndex                   OBJECT-TYPE
    SYNTAX      TmnxLogIdIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdIndex uniquely identifies an event stream log."
    ::= { tmnxLogIdEntry 1 }

tmnxLogIdRowStatus               OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object allows entries to be created and deleted
         in the tmnxLogIdTable.  Deletion of an entry in this
         table will not succeed if tmnxLogIdOperStatus is not
         'outOfService'.  tmnxLogIdOperStatus will not transition
         to 'inService' if tmnxLogIdSource and tmnxLogIdDestination
         and their associated objects have not been set to valid values."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxLogIdEntry 2 }

tmnxLogIdStorageType             OBJECT-TYPE
    SYNTAX      LogStorageType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The storage type for this conceptual row. Conceptual rows having the
         value 'permanent' need not allow write access to any columnar objects
         in the row."
    DEFVAL      { nonVolatile }
    ::= { tmnxLogIdEntry 3 }

tmnxLogIdAdminStatus             OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdAdminStatus specifies the desired administrative
         state for this log."
    DEFVAL      { inService }
    ::= { tmnxLogIdEntry 4 }

tmnxLogIdOperStatus              OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdOperStatus indicates the current operational
         status of this log."
    ::= { tmnxLogIdEntry 5 }

tmnxLogIdDescription             OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdDescription is a user provided description
         string for this log.  It can consist of any printable,
         seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''h }
    ::= { tmnxLogIdEntry 6 }

tmnxLogIdFilterId                OBJECT-TYPE
    SYNTAX      TmnxLogFilterId
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdFilterId is the index into the
         tmnxLogFilterTable to the entry the defines a filter to be
         applied to this log's source event stream to limit the events
         output to this log's destination.  If tmnxLogIdFilterId has a
         value of 0, then all events in the source log are forwarded
         to the destination."
    DEFVAL      { 0 }
    ::= { tmnxLogIdEntry 7 }

tmnxLogIdSource                  OBJECT-TYPE
    SYNTAX      BITS {
        main       (0),
        security   (1),
        change     (2),
        debugTrace (3),
        li         (4)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdSource is a bit mask that specifies the
         log event source stream(s) to be forwarded to the destination
         specified in tmnxLogIdDestination.  Events from more than one
         source may be forwarded to the log destination.

         The 'main' event stream consists of all events that are not explicitly
         directed to any other event stream.

         The 'security' event stream contains all events that affect attempts
         to breach system security such as failed login attempts, attempts to
         access SNMP MIB tables to which the user has not been granted access,
         or attempts to enter a branch of the CLI for which the user is not
         authorized.

         The 'user' activity event stream contains all events that directly
         affect the configuration or operation of the system.

         The 'debugTrace' event stream contains all events configured for
         application or protocol tracing.

         The 'li' event stream contains all events configured for Lawful
         Intercept activities.  An attempt to set the 'li' event stream
         will fail with an inconsistentValue error if the requestor does
         not have access to the 'li' context.  An attempt to set the 'li'
         event stream will fail with an inconsistentValue error if
         tmnxLogIdDestination has the value 'syslog' or 'file'."
    DEFVAL      { {} }
    ::= { tmnxLogIdEntry 8 }

tmnxLogIdDestination             OBJECT-TYPE
    SYNTAX      INTEGER {
        none          (0),
        console       (1),
        syslog        (2),
        snmpTraps     (3),
        file          (4),
        memory        (5),
        netconf       (7),
        subscribedCli (8)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdDestination specifies the event log stream
         destination.  Once this object has been set to a value other than
         the default 'none' it cannot be modified and attempts to reset
         it to another value will fail with an INCONSISTENT VALUE error.

         The 'console' destination causes all selected log events to be
         directed to the system console.  If the console is not connected
         then all entries are dropped.

         The 'syslog' destination sends all selected log events to the
         syslog address configured in tmnxSyslogTargetAddress and
         tmnxSyslogTargetUdpPort in the tmnxSyslogTargetTable row entry
         pointed to by the value of tmnxLogIdSyslogId.  An attempt to
         set this object to 'syslog' will fail with an inconsistentValue
         error if tmnxLogIdSource has the value 'li' set.

         The 'snmpTraps' destination causes events defined as SNMP traps
         to be sent to the configured SNMP trap destinations and also to
         be logged in the NOTIFICATION-LOG-MIB tables.  The allocated memory
         size for the log of transmitted traps is specified in
         tmnxLogIdMaxMemorySize.  The events are logged to memory in a circular
         fashion.  Once the space is full, the oldest entry is replaced with
         a new entry.

         The 'file' destination causes all selected log events to be
         directed to a file on one of the CPM's compact flash discs.
         Details of the file's configuration are in the tmnxLogFileIdTable
         entry pointed to by the value of tmnxLogIdFileId.  An attempt to
         set this object to 'file' will fail with an inconsistentValue
         error if tmnxLogIdSource has the value 'li' set.

         The 'memory' destination causes all selected log events to be
         directed to an in memory storage area.  The allocated memory size
         for the log is specified in tmnxLogIdMaxMemorySize.  The events are
         logged to memory in a circular fashion.  Once the space is full,
         the oldest entry is replaced with a new entry."
    DEFVAL      { none }
    ::= { tmnxLogIdEntry 9 }

tmnxLogIdFileId                  OBJECT-TYPE
    SYNTAX      TmnxLogFileId
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdFileId is the index to the entry in the
         tmnxLogFileIdTable that specifies the file characteristics to be used
         for the destination of the log events written to this log.

         tmnxLogIdOperStatus will not transition to 'inService' until a
         valid value has been set for tmnxLogIdFileId.  This object is
         valid only if tmnxLogIdDestination is set to 'file'.

         This object can be set only once together with tmnxLogIdDestination
         value of 'file'. "
    ::= { tmnxLogIdEntry 10 }

tmnxLogIdSyslogId                OBJECT-TYPE
    SYNTAX      TmnxSyslogIdOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdSyslogId is the index into the
         tmnxSyslogTargetTable for the row entry with the information to format
         event messages to be sent to a specific syslog collector target.

         This object is valid only when tmnxLogIdDestination has a value of
         'syslog'.  If this object has a value of zero (0), then no collector
         is specified and no messages are sent.

         This object can be set only once together with tmnxLogIdDestination
         value of 'syslog'."
    DEFVAL      { 0 }
    ::= { tmnxLogIdEntry 11 }

tmnxLogIdMaxMemorySize           OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 50..3000)
    UNITS       "events"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdMaxMemorySize specifies the amount of memory to
         allocate for this log.  This object can be set only once together with
         tmnxLogIdDestination has a value of 'memory', 'netconf', 'snmpTraps' or 'subscribedCli'.
         For any other value of tmnxLogIdDestination, a read of this object will return zero (0).

         Once a memory size has been specified and the log created, any attempt
         to modify this object will fail with an INCONSISTENT VALUE error."
    DEFVAL      { 100 }
    ::= { tmnxLogIdEntry 12 }

tmnxLogIdConsoleSession          OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "This object exists for the convenience of the Nokia SROS CLI.
         When set to 'true' it indicates that the 'CONSOLE' log output
         should be printed to the Telnet session instead of the CONSOLE
         device.  When a tmnxLogIdEntry is created directly via SNMP,
         setting this object has no meaning and the 'CONSOLE' log output
         will always be sent to the CONSOLE device. This object is obsoleted
         in 15.0 Release."
    DEFVAL      { false }
    ::= { tmnxLogIdEntry 13 }

tmnxLogIdForwarded               OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdForwarded is the count of the number of events
         that have been forwarded to this log's destination.  This counter is
         incremented after an event has been selected by the log filter defined
         in tmnxLogIdFilterId."
    ::= { tmnxLogIdEntry 14 }

tmnxLogIdDropped                 OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdDropped is the count of the number of events
         that have been sent to this logs source(s) and that have not been
         forwarded to the log destination because they were filtered out by the
         log filter defined in tmnxLogIdFilterId."
    ::= { tmnxLogIdEntry 15 }

tmnxLogIdTimeFormat              OBJECT-TYPE
    SYNTAX      INTEGER {
        utc   (1),
        local (2)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdTimeFormat specifies the type of timestamp
         format for events sent to logs where tmnxLogIdDestination has a value
         of either 'syslog (2)' or 'file (4)'.

         When tmnxLogIdTimeFormat has a value of 'utc (1)' timestamps are
         written using the Coordinated Universal Time value.  When
         tmnxLogIdTimeFormat has a value of 'local (2)' timestamps are
         written in the system's local time."
    DEFVAL      { utc }
    ::= { tmnxLogIdEntry 16 }

tmnxLogIdPythonPolicy            OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdPythonPolicy specifies the name of a Python
         policy.

         The name refers to a conceptual row in the
         TIMETRA-PYTHON-MIB::tmnxPythonPolicyTable. The Python policy should
         have Python scripts to modify the log message text.

         While the value of tmnxLogIdAdminStatus is equal to 'inService', a
         non-empty value for this object is only allowed if the value of
         tmnxLogIdDestination is equal to 'syslog'."
    DEFVAL      { ''h }
    ::= { tmnxLogIdEntry 17 }

tmnxLogIdOperDestination         OBJECT-TYPE
    SYNTAX      INTEGER {
        none          (0),
        console       (1),
        syslog        (2),
        snmpTraps     (3),
        file          (4),
        memory        (5),
        cliSession    (6),
        netconf       (7),
        subscribedCli (8)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdOperDestination indicates the operational value
         of event log stream destination.

         The 'console' destination indicates all selected log events will be
         directed to the system console.

         The 'syslog' destination indicates all selected log events will be
         directed to the syslog address configured in tmnxSyslogTargetAddress
         and tmnxSyslogTargetUdpPort in the tmnxSyslogTargetTable row entry
         pointed to by the value of tmnxLogIdSyslogId.

         The 'snmpTraps' destination indicates events defined as SNMP traps
         will be sent to the configured SNMP trap destinations and also to be
         logged in the NOTIFICATION-LOG-MIB tables.

         The 'file' destination indicates all selected log events will be
         directed to a file on one of the CPM's compact flash discs.

         The 'memory' destination indicates all selected log events will be
         directed to an in memory storage area.

         The 'cliSession' destination indicates all selected log events will be
         directed to a cli session. tmnxLogIdDestination will have a value
         'none' in this case."
    DEFVAL      { none }
    ::= { tmnxLogIdEntry 18 }

tmnxLogIdNetconfStream           OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdNetconfStream specifies the name of the NETCONF
         stream associated with this log.

         A non-empty value for this object is only allowed if the value of
         tmnxLogIdDestination is equal to 'netconf'."
    DEFVAL      { "" }
    ::= { tmnxLogIdEntry 19 }

tmnxLogIdName                    OBJECT-TYPE
    SYNTAX      TLNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogIdName specifies an event stream log."
    DEFVAL      { "" }
    ::= { tmnxLogIdEntry 20 }

tmnxLogFilterTable               OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogFilterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "  "
    ::= { tmnxLogObjs 6 }

tmnxLogFilterEntry               OBJECT-TYPE
    SYNTAX      TmnxLogFilterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular Log Filter entry.

         Entries are created by user. Entries are deleted by user. Entry 1001
         is created by the agent for default TmnxLogIdIndex 100.

         There is no StorageType object.  Entries have a presumed
         StorageType of nonVolatile."
    INDEX       { tmnxLogFilterId }
    ::= { tmnxLogFilterTable 1 }

TmnxLogFilterEntry               ::= SEQUENCE
{
    tmnxLogFilterId                  TmnxLogFilterId,
    tmnxLogFilterRowStatus           RowStatus,
    tmnxLogFilterDescription         TItemDescription,
    tmnxLogFilterDefaultAction       TFilterAction,
    tmnxLogFilterInUse               TruthValue,
    tmnxLogFilterName                TLNamedItemOrEmpty
}

tmnxLogFilterId                  OBJECT-TYPE
    SYNTAX      TmnxLogFilterId (1..1500)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterId is a unique index that identifies a
         particular entry in the tmnxLogFilterTable."
    ::= { tmnxLogFilterEntry 1 }

tmnxLogFilterRowStatus           OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Row entries in this table are created and destroyed via SNMP set
         requests."
    ::= { tmnxLogFilterEntry 2 }

tmnxLogFilterDescription         OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterDescription is a user provided description
         string for this log filter.  It can consist of any printable,
         seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''H }
    ::= { tmnxLogFilterEntry 3 }

tmnxLogFilterDefaultAction       OBJECT-TYPE
    SYNTAX      TFilterAction
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The action to take for packets that do not match any filter entries.
         the values default(3), and nat(5) are not allowed."
    DEFVAL      { forward }
    ::= { tmnxLogFilterEntry 4 }

tmnxLogFilterInUse               OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "When tmnxLogFilterInUse has a value of 'true', this filter is
         attached to a log file configuration.  The same tmnxLogFilterEntry
         can be attached to more than one log file."
    ::= { tmnxLogFilterEntry 5 }

tmnxLogFilterName                OBJECT-TYPE
    SYNTAX      TLNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterName specifies particular entry in the
         tmnxLogFilterTable."
    DEFVAL      { "" }
    ::= { tmnxLogFilterEntry 6 }

tmnxLogFilterParamsTable         OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogFilterParamsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all log filter match entries for all log filters."
    ::= { tmnxLogObjs 7 }

tmnxLogFilterParamsEntry         OBJECT-TYPE
    SYNTAX      TmnxLogFilterParamsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular Log Filter Parameter entry. Every Log
         Filter can have zero or more Log Filter Parameter match entries.

         The Log Filter parameter entries are checked in ascending order by
         their index value, tmnxLogFilterParamsIndex.  Upon the first successful
         match, the specified actions are applied as indicated by the value of
         tmnxLogFilterParamsAction.  No further checking against
         remaining tmnxLogFilterParamsEntry rows is done.  Therefore, entries
         in this table should be sequenced from most to least explicit match
         criterion.  It is recommended that multiple parameter entries for a log
         filter should be created with gaps between their index values.  This
         allows a new entry to be inserted into an existing filter policy
         without needing to renumber the already existing filter parameters
         entries.

         A log filter entry in the tmnxLogFilterTable with no entry in the
         tmnxLogFilterParamsTable to define its match criteria set will match
         every log event, and the default action specified by
         tmnxLogFilterDefaultAction will be taken.

         Entries are created by user. Entries are deleted by user.

         There is no StorageType object, entries have a presumed StorageType of
         nonVolatile."
    INDEX       {
        tmnxLogFilterId,
        tmnxLogFilterParamsIndex
    }
    ::= { tmnxLogFilterParamsTable 1 }

TmnxLogFilterParamsEntry         ::= SEQUENCE
{
    tmnxLogFilterParamsIndex         TmnxLogFilterEntryId,
    tmnxLogFilterParamsRowStatus     RowStatus,
    tmnxLogFilterParamsDescription   TItemDescription,
    tmnxLogFilterParamsAction        TFilterActionOrDefault,
    tmnxLogFilterParamsApplication   TNamedItemOrEmpty,
    tmnxLogFilterParamsApplOperator  TmnxLogFilterOperator,
    tmnxLogFilterParamsNumber        TmnxEventNumber,
    tmnxLogFilterParamsNumberOperator TmnxLogFilterOperator,
    tmnxLogFilterParamsSeverity      TmnxPerceivedSeverity,
    tmnxLogFilterParamsSeverityOperator TmnxLogFilterOperator,
    tmnxLogFilterParamsSubject       TNamedItemOrEmpty,
    tmnxLogFilterParamsSubjectOperator TmnxLogFilterOperator,
    tmnxLogFilterParamsSubjectRegexp TruthValue,
    tmnxLogFilterParamsRouter        TNamedItemOrEmpty,
    tmnxLogFilterParamsRouterOperator TmnxLogFilterOperator,
    tmnxLogFilterParamsRouterRegexp  TruthValue,
    tmnxLogFilterParamsMsg           OCTET STRING,
    tmnxLogFilterParamsMsgOperator   TmnxLogFilterOperator,
    tmnxLogFilterParamsMsgRegexp     TruthValue,
    tmnxLogFilterParamsName          TLNamedItemOrEmpty
}

tmnxLogFilterParamsIndex         OBJECT-TYPE
    SYNTAX      TmnxLogFilterEntryId
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        ""
    ::= { tmnxLogFilterParamsEntry 1 }

tmnxLogFilterParamsRowStatus     OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Row Status for this Log filter's parameter entry."
    ::= { tmnxLogFilterParamsEntry 2 }

tmnxLogFilterParamsDescription   OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsDescription is a user provided
         description string for this log filter match entry.  It can consist
         of any printable, seven-bit ASCII characters up to 80 characters in
         length."
    DEFVAL      { ''H }
    ::= { tmnxLogFilterParamsEntry 3 }

tmnxLogFilterParamsAction        OBJECT-TYPE
    SYNTAX      TFilterActionOrDefault
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "the action to take for log events that match this filter entry.
         the value default(3) is allowed.  If tmnxLogFilterParamsAction
         has the value 'default', the action specified by the value
         of tmnxLogFilterDefaultAction is applied to events that match
         this filter entry. The value nat(5) is not allowed."
    DEFVAL      { default }
    ::= { tmnxLogFilterParamsEntry 4 }

tmnxLogFilterParamsApplication   OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Matches log events with the specified application name.  An
         application is the software entity the reports the log event and
         includes IP, MPLS, OSPF, CLI, SERVICES, etc."
    DEFVAL      { ''H }
    ::= { tmnxLogFilterParamsEntry 5 }

tmnxLogFilterParamsApplOperator  OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsApplOperator is the comparison
         operator to use to determine if the log event matches the value
         of tmnxLogFilterParamsApplication.  The only valid values from
         TmnxLogFilterOperator are 'off', 'equal', and 'notEqual'."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 6 }

tmnxLogFilterParamsNumber        OBJECT-TYPE
    SYNTAX      TmnxEventNumber
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsNumber is the log event number to
         be matched.  Event numbers uniquely identify a certain event within
         an application but not across applications."
    DEFVAL      { 0 }
    ::= { tmnxLogFilterParamsEntry 7 }

tmnxLogFilterParamsNumberOperator OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsNumberOperator is the comparison
         operator to use to determine if the log event matches the value of
         tmnxLogFilterParamsNumber."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 8 }

tmnxLogFilterParamsSeverity      OBJECT-TYPE
    SYNTAX      TmnxPerceivedSeverity
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsSeverity is the log event severity
         level to be matched."
    DEFVAL      { none }
    ::= { tmnxLogFilterParamsEntry 9 }

tmnxLogFilterParamsSeverityOperator OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsSeverityOperator is the comparison
         operator to use to determine if the log event matches the value of
         tmnxLogFilterParamsSeverity."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 10 }

tmnxLogFilterParamsSubject       OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsSubject is the log event subject
         string to be matched.  The subject is the entity that the event is
         reported for, such as a port ID."
    DEFVAL      { ''H }
    ::= { tmnxLogFilterParamsEntry 11 }

tmnxLogFilterParamsSubjectOperator OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsSubjectOperator is the comparison
         operator to use to determine if the log event matches the value
         of tmnxLogFilterParamsSubject.  The only valid values of
         TmnxLogFilterOperator to use for the subject string comparison are
         'off', 'equal', and 'notEqual'."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 12 }

tmnxLogFilterParamsSubjectRegexp OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsSubjectRegexp specifies the type
         of string comparison to use to determine if the log event matches
         the value of tmnxLogFilterParamsSubject.  When the value of
         tmnxLogFilterParamsSubjectRegexp is 'true', the string in
         tmnxLogFilterParamsSubject is a regular expression string to be
         matched against the subject string in the log event being filtered.
         When it has a value of 'false', the string in
         tmnxLogFilterParamsSubject is matched exactly by the event
         filter."
    DEFVAL      { false }
    ::= { tmnxLogFilterParamsEntry 13 }

tmnxLogFilterParamsRouter        OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsRouter is the log event router context
         name string to be matched."
    DEFVAL      { ''H }
    ::= { tmnxLogFilterParamsEntry 14 }

tmnxLogFilterParamsRouterOperator OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsRouterOperator is the comparison
         operator to use to determine if the log event matches the value
         of tmnxLogFilterParamsRouter.  The only valid values of
         TmnxLogFilterOperator to use for the router name string comparison
         are 'off', 'equal', and 'notEqual'."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 15 }

tmnxLogFilterParamsRouterRegexp  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsRouterRegexp specifies the type
         of string comparison to use to determine if the log event matches
         the value of tmnxLogFilterParamsRouter.  When the value of
         tmnxLogFilterParamsRouterRegexp is 'true', the string in
         tmnxLogFilterParamsRouter is a regular expression string to be
         matched against the router name string in the log event being
         filtered.  When it has a value of 'false', the string in
         tmnxLogFilterParamsRouter is matched exactly by the event
         filter."
    DEFVAL      { false }
    ::= { tmnxLogFilterParamsEntry 16 }

tmnxLogFilterParamsMsg           OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0|1..400))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsMsg specifies the log event message
         string to be matched. Matching result is determined based on value of
         tmnxLogFilterParamsMsgOperator. Matching type is determined based on
         value of tmnxLogFilterParamsMsgRegexp"
    DEFVAL      { ''H }
    ::= { tmnxLogFilterParamsEntry 17 }

tmnxLogFilterParamsMsgOperator   OBJECT-TYPE
    SYNTAX      TmnxLogFilterOperator
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsMsgOperator specifies the comparison
         operator used to determine if the log event matches the value
         of tmnxLogFilterParamsMsg.  The only valid values of tmnxLogFilterParamsMsgOperator
         to use for the string comparison are 'off', 'equal', and 'notEqual'."
    DEFVAL      { off }
    ::= { tmnxLogFilterParamsEntry 18 }

tmnxLogFilterParamsMsgRegexp     OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsMsgRegexp specifies the type
         of string comparison to use to determine if the log event matches
         the value of tmnxLogFilterParamsMsg.  When the value of
         tmnxLogFilterParamsMsgRegexp is 'true', the string in
         tmnxLogFilterParamsMsg is a regular expression string to be
         matched against the message string in the log event being filtered.
         When it has a value of 'false', the string in
         tmnxLogFilterParamsMsg is matched as substring by the event
         filter."
    DEFVAL      { false }
    ::= { tmnxLogFilterParamsEntry 19 }

tmnxLogFilterParamsName          OBJECT-TYPE
    SYNTAX      TLNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogFilterParamsName specifies particular entry in the
         tmnxLogFilterParamsTable."
    DEFVAL      { "" }
    ::= { tmnxLogFilterParamsEntry 20 }

tmnxSyslogTargetTable            OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxSyslogTargetEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all remote syslog collectors that this agent is configured
         to send syslog messages to."
    ::= { tmnxLogObjs 8 }

tmnxSyslogTargetEntry            OBJECT-TYPE
    SYNTAX      TmnxSyslogTargetEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular Syslog Target entry.

         Entries are created by user. Entries are deleted by user.

         There is no StorageType object, entries have a presumed StorageType of
         nonVolatile. "
    INDEX       { tmnxSyslogTargetIndex }
    ::= { tmnxSyslogTargetTable 1 }

TmnxSyslogTargetEntry            ::= SEQUENCE
{
    tmnxSyslogTargetIndex            TmnxSyslogId,
    tmnxSyslogTargetRowStatus        RowStatus,
    tmnxSyslogTargetDescription      TItemDescription,
    tmnxSyslogTargetAddress          IpAddress,
    tmnxSyslogTargetUdpPort          TmnxUdpPort,
    tmnxSyslogTargetFacility         TmnxSyslogFacility,
    tmnxSyslogTargetSeverity         TmnxSyslogSeverity,
    tmnxSyslogTargetMessagePrefix    TNamedItemOrEmpty,
    tmnxSyslogTargetMessagesDropped  Counter32,
    tmnxSyslogTargetAddrType         InetAddressType,
    tmnxSyslogTargetAddr             InetAddress,
    tmnxSyslogTargetName             TLNamedItemOrEmpty,
    tmnxSyslogTlsClntProfileName     TNamedItemOrEmpty
}

tmnxSyslogTargetIndex            OBJECT-TYPE
    SYNTAX      TmnxSyslogId
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetIndex is a unique arbitrary identifier
         for this syslog collector target.

         The maximum value of tmnxSyslogTargetIndex is limited to 10 for the
         Base router context and to 30 for the VPRN context."
    ::= { tmnxSyslogTargetEntry 1 }

tmnxSyslogTargetRowStatus        OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The tmnxSyslogTargetRowStatus object allows for dynamic creation and
         deletion of row entries in the tmnxSyslogTargetTable as well as the
         activation and deactivation of these entries.

         When this object's value is set to 'notInService (2)', no messages
         will be sent to this target collector and none of its counters will be
         incremented.

         Refer to the RowStatus convention for further details on the behavior
         of this object."
    REFERENCE
        "RFC2579 (Textual Conventions for SMIv2)"
    ::= { tmnxSyslogTargetEntry 2 }

tmnxSyslogTargetDescription      OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetDescription is an administratively
         assigned textual description of this syslog collector target."
    DEFVAL      { ''H }
    ::= { tmnxSyslogTargetEntry 3 }

tmnxSyslogTargetAddress          OBJECT-TYPE
    SYNTAX      IpAddress
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxSyslogTargetAddress is the IPv4 address for
         this syslog message collector target.  If the value of this
         object is '0.0.0.0', then no messages will be sent, nor will
         any counters be incremented.

         This object was made obsolete in release 5.0.  It is replaced
         by the InetAddress pair tmnxSyslogTargetAddrType and
         tmnxSyslogTargetAddr."
    DEFVAL      { '00000000'h }
    ::= { tmnxSyslogTargetEntry 4 }

tmnxSyslogTargetUdpPort          OBJECT-TYPE
    SYNTAX      TmnxUdpPort
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetUdpPort is the UDP port number that is
         used to send messages to this syslog collector target."
    DEFVAL      { 514 }
    ::= { tmnxSyslogTargetEntry 5 }

tmnxSyslogTargetFacility         OBJECT-TYPE
    SYNTAX      TmnxSyslogFacility
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetFacility is the syslog facility number
         that will be encoded in messages sent to this syslog collector target."
    DEFVAL      { local7 }
    ::= { tmnxSyslogTargetEntry 6 }

tmnxSyslogTargetSeverity         OBJECT-TYPE
    SYNTAX      TmnxSyslogSeverity
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetSeverity is the maximum severity level
         of the messages that SHOULD be forwarded to this syslog collector
         target.  The higher the level, the lower the severity."
    DEFVAL      { info }
    ::= { tmnxSyslogTargetEntry 7 }

tmnxSyslogTargetMessagePrefix    OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetMessagePrefix is a string of ABNF
         alphanumeric characters to be prepended as the MSG TAG to the syslog
         MSG CONTENT string and separated from it with a colon and space, ': '."
    DEFVAL      { "TMNX" }
    ::= { tmnxSyslogTargetEntry 8 }

tmnxSyslogTargetMessagesDropped  OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetMessagesDropped is a count of messages
         not sent to this syslog collector target because the severity level of
         the message was above tmnxSyslogTargetSeverity; the higher the level,
         the lower the severity."
    ::= { tmnxSyslogTargetEntry 9 }

tmnxSyslogTargetAddrType         OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetAddrType specifies the type of host
         address to be used for the syslog message collector target. This
         object indicates the type of address stored in the corresponding
         tmnxSyslogTargetAddr object.

         Only 'ipv4', 'ipv6', and 'ipv6z' address types are supported."
    DEFVAL      { unknown }
    ::= { tmnxSyslogTargetEntry 10 }

tmnxSyslogTargetAddr             OBJECT-TYPE
    SYNTAX      InetAddress (SIZE (0|4|16|20))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetAddr specifies the IP host address
         to be used for the syslog message collector target.  If no address
         is specified, ''H, then no messages will be sent nor will
         any counters be incremented.

         The syslog target address type is determined by the value of the
         corresponding tmnxSyslogTargetAddrType object."
    DEFVAL      { ''H }
    ::= { tmnxSyslogTargetEntry 11 }

tmnxSyslogTargetName             OBJECT-TYPE
    SYNTAX      TLNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSyslogTargetName specifies particular entry in the
         tmnxSyslogTargetTable."
    DEFVAL      { "" }
    ::= { tmnxSyslogTargetEntry 12 }

tmnxSyslogTlsClntProfileName     OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxSyslogTlsClntProfileName specifies the
         name for a TLS client profile. If configured, syslog uses TLS."
    DEFVAL      { "" }
    ::= { tmnxSyslogTargetEntry 13 }

tmnxEventAppTable                OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEventAppEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all applications that generate TiMOS logger events."
    ::= { tmnxLogObjs 9 }

tmnxEventAppEntry                OBJECT-TYPE
    SYNTAX      TmnxEventAppEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular application entry.

         Entries are created by the agent when the system initializes.

         There is no StorageType object, entries have a presumed StorageType of
         permanent. "
    INDEX       { tmnxEventAppIndex }
    ::= { tmnxEventAppTable 1 }

TmnxEventAppEntry                ::= SEQUENCE
{
    tmnxEventAppIndex                Unsigned32,
    tmnxEventAppName                 TNamedItem
}

tmnxEventAppIndex                OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventAppIndex is a unique arbitrary identifier for
         this application event generator."
    ::= { tmnxEventAppEntry 1 }

tmnxEventAppName                 OBJECT-TYPE
    SYNTAX      TNamedItem
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventAppName is the name string that is used in TiMOS
         log messages as the application that generated the logged event."
    ::= { tmnxEventAppEntry 2 }

tmnxEventTable                   OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all TiMOS events that can be generated."
    ::= { tmnxLogObjs 10 }

tmnxEventEntry                   OBJECT-TYPE
    SYNTAX      TmnxEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular TiMOS event type entry. Entries are
         created by the agent when the system initializes. There is no
         StorageType object, entries have a presumed StorageType of permanent. "
    INDEX       {
        tmnxEventAppIndex,
        tmnxEventID
    }
    ::= { tmnxEventTable 1 }

TmnxEventEntry                   ::= SEQUENCE
{
    tmnxEventID                      Unsigned32,
    tmnxEventName                    TNamedItem,
    tmnxEventSeverity                TmnxPerceivedSeverity,
    tmnxEventControl                 TruthValue,
    tmnxEventCounter                 Counter32,
    tmnxEventDropCount               Counter32,
    tmnxEventReset                   TmnxActionType,
    tmnxEventThrottle                TruthValue,
    tmnxEventSpecThrottle            TruthValue,
    tmnxEventSpecThrottleLimit       Unsigned32,
    tmnxEventSpecThrottleIntval      Unsigned32,
    tmnxEventSpecThrottleDef         TruthValue,
    tmnxEventSpecThrottleLimitDef    Unsigned32,
    tmnxEventSpecThrottleIntvalDef   Unsigned32,
    tmnxEventRepeat                  TruthValue
}

tmnxEventID                      OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventID is a unique arbitrary identifier for indexing
         event type entries within an event generator application as identified
         by the value of tmnxEventAppIndex."
    ::= { tmnxEventEntry 1 }

tmnxEventName                    OBJECT-TYPE
    SYNTAX      TNamedItem
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventName is a short name string used to describe
         this event type."
    ::= { tmnxEventEntry 2 }

tmnxEventSeverity                OBJECT-TYPE
    SYNTAX      TmnxPerceivedSeverity
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSeverity specifies the severity level that will
         be associated with this type of event when it is generated."
    ::= { tmnxEventEntry 3 }

tmnxEventControl                 OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventControl determines whether or not events
         of this type will be generated or suppressed.  When it has a value
         of 'true', the event is generated and tmnxEventCounter is incremented.
         When it has a value of 'false', the event is suppressed and
         tmnxEventDropCount is incremented."
    ::= { tmnxEventEntry 4 }

tmnxEventCounter                 OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventCounter is the number of times an event of this
         type has been generated."
    ::= { tmnxEventEntry 5 }

tmnxEventDropCount               OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventDropCount is the number of times and event
         of this type has been suppressed because tmnxEventControl is set to
         'false'.  When tmnxEventControl is set to 'true', tmnxEventDropCount
         indicates the number of events dropped because of logger input
         queue size overrun or dropped because of throttling when
         tmnxEventThrottle is set to 'true'."
    ::= { tmnxEventEntry 6 }

tmnxEventReset                   OBJECT-TYPE
    SYNTAX      TmnxActionType
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Setting tmnxEventReset to 'doAction (1)' causes the agent to reset the
         values of tmnxEventSeverity and tmnxEventControl to the default values
         for this event type."
    DEFVAL      { notApplicable }
    ::= { tmnxEventEntry 7 }

tmnxEventThrottle                OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventThrottle determines whether or not events
         of this type will be throttled.  When it has a value
         of 'true', the event is throttled at the rate indicated by the
         value of tmnxEventThrottleLimit and tmnxEventThrottleInterval.
         When it has a value of 'false', no event throttling is applied."
    DEFVAL      { false }
    ::= { tmnxEventEntry 8 }

tmnxEventSpecThrottle            OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottle specifies if events of this type
         will be throttled using the parameters specific for this event.

         When the value of tmnxEventSpecThrottle is equal to 'true', the event
         is throttled at the rate indicated by the value of
         tmnxEventSpecThrottleLimit and tmnxEventSpecThrottleIntval.

         When it has a value of 'false', no event-specific throttling is
         applied.

         The default value depends on the event."
    ::= { tmnxEventEntry 9 }

tmnxEventSpecThrottleLimit       OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 1..20000)
    UNITS       "events"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottleLimit specifies the number of times
         that this event can be logged within the tmnxEventSpecThrottleIntval.

         Once this limit has been reached, any additional events of this type
         will be dropped, i.e. tmnxEventDropCount will be incremented.

         At the end of the specific throttle interval if any events have been
         dropped a tmnxLogEventThrottled notification will be sent if the rate
         is applied to the whole stream of log events of this type; otherwise,
         if the rate is applied to each source of this type of event, the
         TIMETRA-SYSTEM-MIB::tmnxTrapDropped will be sent.

         The value must be zero while the value of tmnxEventSpecThrottle is
         'false'.

         The default value depends on the event type."
    ::= { tmnxEventEntry 10 }

tmnxEventSpecThrottleIntval      OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 1..1200)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottleIntval specifies the number of
         seconds that the event-specific throttling interval lasts.

         The value must be zero while the value of tmnxEventSpecThrottle is
         'false'.

         The default value depends on the event type."
    ::= { tmnxEventEntry 11 }

tmnxEventSpecThrottleDef         OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottleDef indicates the default value of
         tmnxEventSpecThrottle."
    ::= { tmnxEventEntry 12 }

tmnxEventSpecThrottleLimitDef    OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 1..20000)
    UNITS       "events"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottleLimitDef indicates the default value
         of the object tmnxEventSpecThrottleLimit.

         The value zero indicates that there is by default no event-specific
         throttling for this event."
    ::= { tmnxEventEntry 13 }

tmnxEventSpecThrottleIntvalDef   OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 1..1200)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSpecThrottleIntvalDef indicates the default
         value of tmnxEventSpecThrottleIntval.

         The value zero indicates that there is by default no event-specific
         throttling for this type of event."
    ::= { tmnxEventEntry 14 }

tmnxEventRepeat                  OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "repeat"
    DEFVAL      { false }
    ::= { tmnxEventEntry 15 }

tmnxSnmpTrapGroupTable           OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxSnmpTrapGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "A table of all remote SNMP trap collectors to which this agent is
         configured to send SNMP notifications messages.

         This table was made obsolete in the 5.0 release and is replaced with
         tmnxSnmpTrapDestTable."
    ::= { tmnxLogObjs 11 }

tmnxSnmpTrapGroupEntry           OBJECT-TYPE
    SYNTAX      TmnxSnmpTrapGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "Information about a particular SNMP trap destination entry. The first
         index instance creates and snmp trap group to be associated with the
         event log with the same value for tmnxLogIdIndex. The second and third
         indexes specify a remote SNMP trap destination that will be sent SNMP
         notification messages from the associated event log.

         Entries are created by user. Entries are deleted by user.

         There is no StorageType object, entries have a presumed StorageType of
         nonVolatile.

         This table was made obsolete in the 5.0 release and is replaced with
         the tmnxSnmpTrapDestTable."
    INDEX       {
        tmnxStgIndex,
        tmnxStgDestAddress,
        tmnxStgDestPort
    }
    ::= { tmnxSnmpTrapGroupTable 1 }

TmnxSnmpTrapGroupEntry           ::= SEQUENCE
{
    tmnxStgIndex                     TmnxStgIndex,
    tmnxStgDestAddress               IpAddress,
    tmnxStgDestPort                  TmnxUdpPort,
    tmnxStgRowStatus                 RowStatus,
    tmnxStgDescription               TItemDescription,
    tmnxStgVersion                   SnmpMessageProcessingModel,
    tmnxStgNotifyCommunity           OCTET STRING,
    tmnxStgSecurityLevel             SnmpSecurityLevel
}

tmnxStgIndex                     OBJECT-TYPE
    SYNTAX      TmnxStgIndex
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgIndex specifies an snmp trap group to be
         associated with the event log with the same value for tmnxLogIdIndex.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdIndex."
    ::= { tmnxSnmpTrapGroupEntry 1 }

tmnxStgDestAddress               OBJECT-TYPE
    SYNTAX      IpAddress
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgDestAddress is the IPv4 address for
         this remote snmp notification destination.  If the value of this
         object is '0.0.0.0', then no messages will be sent, nor will
         any counters be incremented.

         This object was made obsolete in the 5.0 release.  It is
         replaced by the InetAddressType/InetAddress objects
         tmnxStdDestAddrType and tmnxStdDestAddr."
    DEFVAL      { '00000000'h }
    ::= { tmnxSnmpTrapGroupEntry 2 }

tmnxStgDestPort                  OBJECT-TYPE
    SYNTAX      TmnxUdpPort
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgDestPort is the UDP port number that is used to
         send messages to this remote SNMP notification destination.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdDestPort."
    DEFVAL      { 162 }
    ::= { tmnxSnmpTrapGroupEntry 3 }

tmnxStgRowStatus                 OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The tmnxStgRowStatus object allows for dynamic creation and deletion
         of row entries in the tmnxSnmpTrapGroupTable as well as the activation
         and deactivation of these entries.

         When this object's value is set to 'notInService (2)', no messages
         will be sent to this snmp trap group and none of its counters will be
         incremented.

         Refer to the RowStatus convention for further details on the behavior
         of this object.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdRowStatus."
    REFERENCE
        "RFC2579 (Textual Conventions for SMIv2)"
    ::= { tmnxSnmpTrapGroupEntry 4 }

tmnxStgDescription               OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgDescription is an administratively assigned
         textual description of this snmp trap destination.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdDescription."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapGroupEntry 5 }

tmnxStgVersion                   OBJECT-TYPE
    SYNTAX      SnmpMessageProcessingModel
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgVersion specifies the SNMP version that will be
         used to format notification messages sent to this snmp trap
         destination.

         The values supported by the Nokia SROS series SNMP agent are:
                        0  for SNMPv1
                        1  for SNMPv2c
                        3  for SNMPv3

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdVersion."
    DEFVAL      { 3 }
    ::= { tmnxSnmpTrapGroupEntry 6 }

tmnxStgNotifyCommunity           OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0..32))
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgNotifyCommunity specifies the SNMPv1 or
         SNMPv2c community name string or the SNMPv3 security name
         used when an SNMP notification message is sent to this
         trap destination.  If the value of this object is the empty
         string, then no messages will be sent nor will any counters be
         incremented.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdVersion."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapGroupEntry 7 }

tmnxStgSecurityLevel             OBJECT-TYPE
    SYNTAX      SnmpSecurityLevel
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxStgSecurityLevel specifies the level of security at
         which SNMP notification messages will be sent to the SNMP trap
         destination when tmnxStgVersion has a value of '3' for SNMPv3.

         This object was made obsolete in the 5.0 release.  It is
         replaced by tmnxStdSecurityLevel."
    DEFVAL      { noAuthNoPriv }
    ::= { tmnxSnmpTrapGroupEntry 8 }

tmnxEventTest                    OBJECT-TYPE
    SYNTAX      TmnxActionType
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Setting tmnxEventTest to 'doAction' causes the tmnxTestEvent
         notification to be generated."
    DEFVAL      { notApplicable }
    ::= { tmnxLogObjs 12 }

tmnxEventThrottleLimit           OBJECT-TYPE
    SYNTAX      Unsigned32 (1..20000)
    UNITS       "events"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventThrottleLimit specifies the number of
         log events that can be logged within the tmnxEventThrottleInterval
         for a specific entry in the tmnxEventTable.  Once the limit has
         been reached, any additional events of that type will be dropped,
         i.e. tmnxEventDropCount will be incremented.  At the end of the
         throttle interval if any events have been dropped a
         tmnxLogEventThrottled notification will be sent."
    DEFVAL      { 2000 }
    ::= { tmnxLogObjs 13 }

tmnxEventThrottleInterval        OBJECT-TYPE
    SYNTAX      Unsigned32 (1..1200)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventThrottleInterval specifies the number of seconds
         that an event throttling interval lasts."
    DEFVAL      { 1 }
    ::= { tmnxLogObjs 14 }

tmnxSnmpSetErrsMax               OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSnmpSetErrsMax indicates the maximum number of
         entries the agent will create in the tmnxSnmpSetErrsTable. Once the
         table is full the agent will delete the oldest entry in the table in
         order to add new entries."
    ::= { tmnxLogObjs 15 }

tmnxSnmpSetErrsTable             OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxSnmpSetErrsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of recent SNMP SET failures.  Only the SET errs from
         remote SNMP manager requests are saved in this table.  Only
         SET errs detected by the SNMP engine in the test phase
         consistency check method functions are saved.  SET errors that
         are caught by the preliminary access and ASN.1 decoding phase
         are not saved.  These are errs such as noAccess, notWritable,
         wrongType, wrongLength and wrongEncoding.  Note that notWritable,
         wrongType, and wrongLength errs may sometimes be generated by
         the consistency check; in this case they will be saved in this
         table.

         SET errs caused by local CLI sessions are not saved.

         The tmnxSnmpSetErrsTable is intended to provide an aide to
         Network Management Systems (NMS) developers.  When an SNMP SET
         fails during the consistency checking test phase, this table may
         provide more detailed failure reason information than the simple
         SNMP error code value in the SNMP response PDU."
    ::= { tmnxLogObjs 16 }

tmnxSnmpSetErrsEntry             OBJECT-TYPE
    SYNTAX      TmnxSnmpSetErrsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular SNMP SET error.  The first two
         index instances identify the SNMP manager who sent the SNMP SET
         request that failed.  The third index specifies the SNMP request ID
         (sequence number) of the SNMP SET request that failed.

         Entries are created by the agent. Entries are deleted by the agent.

         There is no StorageType object, entries have a presumed StorageType of
         volatile."
    INDEX       {
        tmnxSseAddressType,
        tmnxSseAddress,
        tmnxSseSnmpPort,
        tmnxSseRequestId
    }
    ::= { tmnxSnmpSetErrsTable 1 }

TmnxSnmpSetErrsEntry             ::= SEQUENCE
{
    tmnxSseAddressType               InetAddressType,
    tmnxSseAddress                   InetAddress,
    tmnxSseSnmpPort                  TmnxUdpPort,
    tmnxSseRequestId                 Unsigned32,
    tmnxSseVersion                   SnmpMessageProcessingModel,
    tmnxSseSeverityLevel             TmnxPerceivedSeverity,
    tmnxSseModuleId                  Unsigned32,
    tmnxSseModuleName                TNamedItem,
    tmnxSseErrorCode                 Unsigned32,
    tmnxSseErrorName                 DisplayString,
    tmnxSseErrorMsg                  DisplayString,
    tmnxSseExtraText                 OCTET STRING,
    tmnxSseTimestamp                 TimeStamp
}

tmnxSseAddressType               OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseAddressType indicates the IP address
         type of address specified in tmnxSseAddress.  'ipv4' and
         'ipv6' are the only address type values supported."
    ::= { tmnxSnmpSetErrsEntry 1 }

tmnxSseAddress                   OBJECT-TYPE
    SYNTAX      InetAddress (SIZE (4|16))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseAddress is the IP address of the SNMP manager that
         sent the SNMP SET request that failed for this error reason."
    ::= { tmnxSnmpSetErrsEntry 2 }

tmnxSseSnmpPort                  OBJECT-TYPE
    SYNTAX      TmnxUdpPort
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseSnmpPort is the UDP port number of the SNMP
         manager that sent the SNMP SET request that failed for this error
         reason."
    ::= { tmnxSnmpSetErrsEntry 3 }

tmnxSseRequestId                 OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseRequestId indicates the request ID of the SNMP
         SNMP SET request that failed for this error reason."
    ::= { tmnxSnmpSetErrsEntry 4 }

tmnxSseVersion                   OBJECT-TYPE
    SYNTAX      SnmpMessageProcessingModel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseVersion indicates the SNMP version of the SNMP SET
         request that failed.

         The values supported by the Nokia SROS series SNMP agent are:
                        0  for SNMPv1
                        1  for SNMPv2c
                        3  for SNMPv3"
    ::= { tmnxSnmpSetErrsEntry 5 }

tmnxSseSeverityLevel             OBJECT-TYPE
    SYNTAX      TmnxPerceivedSeverity
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseSeverityLevel indicates severity level that is
         associated with this type SNMP SET error."
    ::= { tmnxSnmpSetErrsEntry 6 }

tmnxSseModuleId                  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseModuleId indicates a unique arbitrary
         identified for the TiMOS application module that generated
         this SNMP SET error.  NOTE: This is NOT the same value used
         for tmnxEventAppIndex."
    ::= { tmnxSnmpSetErrsEntry 7 }

tmnxSseModuleName                OBJECT-TYPE
    SYNTAX      TNamedItem
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseModuleName indicates the name string of the TiMOS
         application module that generated this SNMP SET error. NOTE: This is
         NOT the same value used for tmnxEventAppName."
    ::= { tmnxSnmpSetErrsEntry 8 }

tmnxSseErrorCode                 OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseErrorCode indicates the error number associated
         with this SNMP SET error.  The error numbers are unique within
         a tmnxSseModuleId.  They are not unique across all modules so
         both the module name and error number are required to identify
         a particular error message."
    ::= { tmnxSnmpSetErrsEntry 9 }

tmnxSseErrorName                 OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..64))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseErrorName indicates the error name associated
         with this SNMP SET error.  The error names are unique within
         a tmnxSseModuleId.  They are not unique across all modules so
         both the module name and error name are required to identify
         a particular error message."
    ::= { tmnxSnmpSetErrsEntry 10 }

tmnxSseErrorMsg                  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseErrorMsg indicates the fixed error message text
         associated with this SNMP SET error identified by the values of
         tmnxSseModuleId and tmnxSseErrorCode."
    ::= { tmnxSnmpSetErrsEntry 11 }

tmnxSseExtraText                 OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0..320))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseExtraText indicates the fixed run-time variable
         message text associated with this SNMP SET error identified by the
         values of tmnxSseModuleId and tmnxSseErrorCode.  If the extra text
         was truncated to fit into buffer size allowed, the last character
         will be an asterisk (*)."
    ::= { tmnxSnmpSetErrsEntry 12 }

tmnxSseTimestamp                 OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxSseTimestamp indicates the sysUpTime value when this
         tmnxSnmpSetErrsEntry was created by the agent."
    ::= { tmnxSnmpSetErrsEntry 13 }

tmnxSnmpTrapLogTable             OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxSnmpTrapLogEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all remote SNMP trap logs to which this agent is configured
         to send SNMP notifications messages."
    ::= { tmnxLogObjs 17 }

tmnxSnmpTrapLogEntry             OBJECT-TYPE
    SYNTAX      TmnxSnmpTrapLogEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each row entry in the tmnxSnmpTrapLogTable represents additional
         columns for attributes specific to the Nokia SROS series
         implementation of SNMP-NOTIFICATION-MIB::snmpNotifyTable."
    AUGMENTS    { snmpNotifyEntry }
    ::= { tmnxSnmpTrapLogTable 1 }

TmnxSnmpTrapLogEntry             ::= SEQUENCE
{
    tmnxSnmpTrapLogDescription       TItemDescription,
    snmpNotifyId                     TmnxLogIdIndex
}

tmnxSnmpTrapLogDescription       OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxSnmpTrapLogDescription is an administratively
         assigned textual description of this snmp trap log."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapLogEntry 1 }

snmpNotifyId                     OBJECT-TYPE
    SYNTAX      TmnxLogIdIndex (1..100)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of snmpNotifyId creates association with log with the same
         value of tmnxLogIdIndex. It is number representation of
         snmpNotifyName. Usage of default Netconf log 101 not allowed."
    ::= { tmnxSnmpTrapLogEntry 2 }

tmnxSnmpTrapDestTable            OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxSnmpTrapDestEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of all remote SNMP IPv4/v6 trap collectors to which this agent
         is configured to send SNMP notification messages."
    ::= { tmnxLogObjs 18 }

tmnxSnmpTrapDestEntry            OBJECT-TYPE
    SYNTAX      TmnxSnmpTrapDestEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a particular SNMP notification destination entry.
         The first index instance creates an snmp notification group to be
         associated with the event log with the same value for tmnxLogIdIndex.
         The second index specifies an administrative name to identify a
         specific SNMP notification target.

         Entries are created by user. Entries are deleted by user.

         There is no StorageType object, entries have a presumed StorageType of
         nonVolatile."
    INDEX       {
        tmnxStdIndex,
        IMPLIED tmnxStdName
    }
    ::= { tmnxSnmpTrapDestTable 1 }

TmnxSnmpTrapDestEntry            ::= SEQUENCE
{
    tmnxStdIndex                     TmnxStgIndex,
    tmnxStdName                      SnmpAdminString,
    tmnxStdRowStatus                 RowStatus,
    tmnxStdRowLastChanged            TimeStamp,
    tmnxStdDestAddrType              InetAddressType,
    tmnxStdDestAddr                  InetAddress,
    tmnxStdDestPort                  TmnxUdpPort,
    tmnxStdDescription               TItemDescription,
    tmnxStdVersion                   SnmpMessageProcessingModel,
    tmnxStdNotifyCommunity           OCTET STRING,
    tmnxStdSecurityLevel             SnmpSecurityLevel,
    tmnxStdReplay                    TruthValue,
    tmnxStdReplayStart               Unsigned32,
    tmnxStdReplayLastTime            TimeStamp,
    tmnxStdDyingGasp                 TruthValue
}

tmnxStdIndex                     OBJECT-TYPE
    SYNTAX      TmnxStgIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdIndex specifies an snmp notification group to be
         associated with the event log with the same value for tmnxLogIdIndex."
    ::= { tmnxSnmpTrapDestEntry 1 }

tmnxStdName                      OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (1..28))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdName specifies the name of an snmp notification
         destination within the snmp notification group specified by
         tmnxLogIdIndex."
    ::= { tmnxSnmpTrapDestEntry 2 }

tmnxStdRowStatus                 OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The tmnxStdRowStatus object allows for dynamic creation and deletion
         of row entries in the tmnxSnmpTrapDestTable as well as the activation
         and deactivation of these entries.

         In order for 'createAndGo' row creation to succeed or status to
         transition to 'active' a value must be set for tmnxStdNotifyCommunity.

         In order for 'createAndGo' row creation to succeed or status to
         transition to 'active' an entry must exist in the
         SNMP-NOTIFICATION-MIB::snmpNotifyTable with an snmpNotifyName index
         that is the ASCII string representation of the value of tmnxStdIndex.

         When this object's value is set to 'notInService (2)', no messages
         will be sent to this snmp notification collector and none of its
         counters will be incremented.

         Refer to the RowStatus convention for further details on the behavior
         of this object."
    REFERENCE
        "RFC2579 (Textual Conventions for SMIv2)"
    ::= { tmnxSnmpTrapDestEntry 3 }

tmnxStdRowLastChanged            OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdRowLastChanged indicates the sysUpTime when the
         value of a writable object in this row entry was modified."
    ::= { tmnxSnmpTrapDestEntry 4 }

tmnxStdDestAddrType              OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdDestAddrType specifies the type of
         host address to be used for the remote SNMP notification
         collector.  This object indicates the type of address stored
         in the corresponding tmnxStdDestAddr object.

         If the value of this object is 'unknown', then no messages will be
         sent nor will any counters be incremented.

         If tmnxStdDestAddrType is not set in the same PDU with
         tmnxStdDestAddr, the set request will fail with an inconsistentValue
         error."
    DEFVAL      { unknown }
    ::= { tmnxSnmpTrapDestEntry 5 }

tmnxStdDestAddr                  OBJECT-TYPE
    SYNTAX      InetAddress (SIZE (0|4|16|20))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdDestAddr specifies the IP host address to be used
         for the remote SNMP notification collector.

         The SNMP notification collector IP address type is determined by the
         value of the corresponding tmnxStdDestAddrType object.

         If the value of this object is empty or all NULLs, then no messages
         will be sent nor will any counters be incremented.

         If tmnxStdDestAddrType is not set in the same PDU with
         tmnxStdDestAddr, the set request will fail with an inconsistentValue
         error."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapDestEntry 6 }

tmnxStdDestPort                  OBJECT-TYPE
    SYNTAX      TmnxUdpPort
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdDestPort is the UDP port number that is used to
         send messages to this remote SNMP notification collector."
    DEFVAL      { 162 }
    ::= { tmnxSnmpTrapDestEntry 7 }

tmnxStdDescription               OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdDescription is an administratively assigned
         textual description of this SNMP notification collector."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapDestEntry 8 }

tmnxStdVersion                   OBJECT-TYPE
    SYNTAX      SnmpMessageProcessingModel
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdVersion specifies the SNMP version that will be
         used to format notification messages sent to this SNMP notification
         collector.

         The values supported by the Nokia SROS series SNMP agent are:
                        0  for SNMPv1
                        1  for SNMPv2c
                        3  for SNMPv3"
    DEFVAL      { 3 }
    ::= { tmnxSnmpTrapDestEntry 9 }

tmnxStdNotifyCommunity           OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0..31))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdNotifyCommunity specifies the SNMPv1 or
         SNMPv2c community name string or the SNMPv3 security name
         used when an SNMP notification message is sent to this
         SNMP notification collector.  If the value of this object is
         the empty string, then no messages will be sent nor will any
         counters be incremented."
    DEFVAL      { ''H }
    ::= { tmnxSnmpTrapDestEntry 10 }

tmnxStdSecurityLevel             OBJECT-TYPE
    SYNTAX      SnmpSecurityLevel
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdSecurityLevel specifies the level of security at
         which SNMP notification messages will be sent to the SNMP notification
         collector when tmnxStdVersion has a value of '3' for SNMPv3."
    DEFVAL      { noAuthNoPriv }
    ::= { tmnxSnmpTrapDestEntry 11 }

tmnxStdReplay                    OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdReplay specifies whether or not to resend
         notifications that were generated while this notification destination
         did not have a route installed for it in the route tables."
    DEFVAL      { false }
    ::= { tmnxSnmpTrapDestEntry 12 }

tmnxStdReplayStart               OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdReplayStart indicates the SNMP notification
         request ID of the first event that could not be generated because
         there is no route to this notification target address.

         Events will be resent when this notification target address is
         readded to the route tables, on either an in-band or out-of-band
         interface.  The agent searches backwards in the event log and
         begins resending events from the oldest event that has a timestamp
         <= 5 centiseconds less than the timestamp of the
         event with this request ID.  Note that if the outage is long
         and a large number of events are generated in the meantime,
         it is possible that the log memory storage has wrapped and the
         event data for this request ID is no longer available.  In that case,
         the oldest event saved in the log will be the first event resent.

         A value of 0 indicates that there are no missed events waiting to be
         resent."
    ::= { tmnxSnmpTrapDestEntry 13 }

tmnxStdReplayLastTime            OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdReplayLastTime indicates the sysUpTime when
         missed events were last replayed to this SNMP notification target
         address.  A value of 0 indicates that no missed events have been
         replayed to this SNMP notification target address."
    ::= { tmnxSnmpTrapDestEntry 14 }

tmnxStdDyingGasp                 OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxStdDyingGasp specifies whether the tmnxSysDyingGasp
         trap message is to be sent using this SNMP notification target when
         the system goes down due to power loss.

         tmnxStdDyingGasp can only be set to 'true' on at most 3 SNMP
         notification targets."
    DEFVAL      { false }
    ::= { tmnxSnmpTrapDestEntry 15 }

tmnxStdMaxTargets                OBJECT-TYPE
    SYNTAX      Unsigned32 (10..100)
    UNITS       "trap-targets"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The maximum number of tmnxSnmpTrapDestTable row entries that can be
         created for a specific tmnxStdIndex that represents an snmp
         notification group."
    DEFVAL      { 25 }
    ::= { tmnxLogObjs 19 }

tmnxLogApCustRecordTable         OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogApCustRecordEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxLogApCustRecordTable augments
         tmnxLogApTable. The table allows to configure the layout and setting
         for a custom accounting record associated with this accounting policy."
    ::= { tmnxLogObjs 20 }

tmnxLogApCustRecordEntry         OBJECT-TYPE
    SYNTAX      TmnxLogApCustRecordEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the tmnxLogApCustRecordTable. Entries in this
         table are created and destroyed via SNMP Set requests to the
         tmnxLogApRowStatus object of the tmnxLogApTable."
    AUGMENTS    { tmnxLogApEntry }
    ::= { tmnxLogApCustRecordTable 1 }

TmnxLogApCustRecordEntry         ::= SEQUENCE
{
    tmnxLogApCrLastChanged           TimeStamp,
    tmnxLogApCrSignChangeDelta       Unsigned32,
    tmnxLogApCrSignChangeQueue       TQueueIdOrAll,
    tmnxLogApCrSignChangeOCntr       THsmdaCounterIdOrZeroOrAll,
    tmnxLogApCrSignChangeQICounters  TmnxAccPlcyQICounters,
    tmnxLogApCrSignChangeQECounters  TmnxAccPlcyQECounters,
    tmnxLogApCrSignChangeOICounters  TmnxAccPlcyOICounters,
    tmnxLogApCrSignChangeOECounters  TmnxAccPlcyOECounters,
    tmnxLogApCrSignChangeAACounters  TmnxAccPlcyAACounters,
    tmnxLogApCrAACounters            TmnxAccPlcyAACounters,
    tmnxLogApCrAASubAttributes       TmnxAccPlcyAASubAttributes,
    tmnxLogApCrSignChangePolicer     Integer32,
    tmnxLogApCrSignChangePICounters  TmnxAccPlcyPolicerICounters,
    tmnxLogApCrSignChangePECounters  TmnxAccPlcyPolicerECounters
}

tmnxLogApCrLastChanged           OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrLastChanged indicates the sysUpTime when an
         object in this table was last modified. A Value 0 means that no change
         was made to this row since the box was last initialized."
    ::= { tmnxLogApCustRecordEntry 1 }

tmnxLogApCrSignChangeDelta       OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeDelta specifies the delta
         change  (significant change) that is required for the custom record
         to be written to the xml file."
    DEFVAL      { 0 }
    ::= { tmnxLogApCustRecordEntry 2 }

tmnxLogApCrSignChangeQueue       OBJECT-TYPE
    SYNTAX      TQueueIdOrAll
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeQueue specifies the reference queue
         to which the significant change defined in tmnxLogApCrSignChangeDelta
         applies."
    DEFVAL      { 0 }
    ::= { tmnxLogApCustRecordEntry 3 }

tmnxLogApCrSignChangeOCntr       OBJECT-TYPE
    SYNTAX      THsmdaCounterIdOrZeroOrAll
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeOCntr specifies the counter-id that
         will be taken as reference to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies."
    DEFVAL      { 0 }
    ::= { tmnxLogApCustRecordEntry 4 }

tmnxLogApCrSignChangeQICounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyQICounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeQICounters specifies the ingress
         counter Ids in the queue defined by tmnxLogApCrSignChangeQueue to be
         taken as reference to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies.

         A non-zero value of this object is only allowed if the object
         tmnxLogApCrSignChangeQueue has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 5 }

tmnxLogApCrSignChangeQECounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyQECounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeQECounters specifies the egress
         counter Ids in the queue defined by tmnxLogApCrSignChangeQueue to be
         taken as reference to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies.

         A non-zero value of this object is only allowed if the object
         tmnxLogApCrSignChangeQueue has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 6 }

tmnxLogApCrSignChangeOICounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyOICounters
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeOICounters specifies the ingress
         counter Ids in the counter-group defined by tmnxLogApCrSignChangeOCntr
         to be taken as reference to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies.

         A non-zero value of this object is only allowed if the object
         tmnxLogApCrSignChangeOCntr has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 7 }

tmnxLogApCrSignChangeOECounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyOECounters
    MAX-ACCESS  read-write
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeOECounters specifies the egress
         counter Ids in the counter-group defined by tmnxLogApCrSignChangeOCntr
         to be taken as reference to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies.

         A non-zero value of this object is only allowed if the object
         tmnxLogApCrSignChangeOCntr has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 8 }

tmnxLogApCrSignChangeAACounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyAACounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangeAACounters specifies the
         AA (Application assurance) counter Ids  to be taken as reference to
         which the significant change defined in tmnxLogApCrSignChangeDelta
         applies.

         A non-zero value of this object is only allowed if both the objects
         tmnxLogApCrSignChangeOCntr and tmnxLogApCrSignChangeQueue are zero.

         Also, a non-zero value for this object is only allowed if the object
         tmnxLogApCrSignChangeDelta is either 0 or 1."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 9 }

tmnxLogApCrAACounters            OBJECT-TYPE
    SYNTAX      TmnxAccPlcyAACounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrAACounters specifies the list of AA
         (Application Assurance) counters that need to be collected in this
         custom record."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 10 }

tmnxLogApCrAASubAttributes       OBJECT-TYPE
    SYNTAX      TmnxAccPlcyAASubAttributes
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrAASubAttributes specifies the list of AA
         (Application Assurance) subscriber attributes that must be included in
         this custom record."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 11 }

tmnxLogApCrSignChangePolicer     OBJECT-TYPE
    SYNTAX      Integer32 (-1 | 0..63)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangePolicer specifies the reference
         policer to which the significant change defined in
         tmnxLogApCrSignChangeDelta applies.

         A value of zero means that the significant change does not apply to
         any policer.

         A value of minus one means that the significant change applies to any
         policer."
    DEFVAL      { 0 }
    ::= { tmnxLogApCustRecordEntry 12 }

tmnxLogApCrSignChangePICounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyPolicerICounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangePICounters specifies the ingress
         counters in the policer defined by tmnxLogApCrSignChangePolicer to
         which the significant change defined in tmnxLogApCrSignChangeDelta
         applies.

         A non-empty value of this object is only allowed if the object
         tmnxLogApCrSignChangePolicer has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 13 }

tmnxLogApCrSignChangePECounters  OBJECT-TYPE
    SYNTAX      TmnxAccPlcyPolicerECounters
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrSignChangePECounters specifies the egress
         counters in the policer defined by tmnxLogApCrSignChangePolicer to
         which the significant change defined in tmnxLogApCrSignChangeDelta
         applies.

         A non-empty value of this object is only allowed if the object
         tmnxLogApCrSignChangeQueue has a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordEntry 14 }

tmnxLogApCustRecordQueueTable    OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogApCustRecordQueueEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxLogApCustRecordQueueTable allows to create
         custom record queue information for a given accounting policy. Rows
         can only be created for existing accounting policies (as defined in
         tmnxLogApTable)."
    ::= { tmnxLogObjs 21 }

tmnxLogApCustRecordQueueEntry    OBJECT-TYPE
    SYNTAX      TmnxLogApCustRecordQueueEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the tmnxLogApCustRecordQueueTable. Entries in this
         table are created and destroyed via SNMP Set requests."
    INDEX       {
        tmnxLogApPolicyId,
        tmnxLogApCrQueueId
    }
    ::= { tmnxLogApCustRecordQueueTable 1 }

TmnxLogApCustRecordQueueEntry    ::= SEQUENCE
{
    tmnxLogApCrQueueId               TQueueId,
    tmnxLogApCrQueueRowStatus        RowStatus,
    tmnxLogApCrQueueLastChanged      TimeStamp,
    tmnxLogApCrQueueICounters        TmnxAccPlcyQICounters,
    tmnxLogApCrQueueECounters        TmnxAccPlcyQECounters
}

tmnxLogApCrQueueId               OBJECT-TYPE
    SYNTAX      TQueueId (1..32)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrQueueId specifies the queue ID for which
         counters will be collected in this custom record. The counters that
         will be collected are defined in tmnxLogApCrQueueICounters and
         tmnxLogApCrQueueECounters."
    ::= { tmnxLogApCustRecordQueueEntry 1 }

tmnxLogApCrQueueRowStatus        OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Row Status of the entry. This allows creation/deletion of rows in this
         table."
    ::= { tmnxLogApCustRecordQueueEntry 2 }

tmnxLogApCrQueueLastChanged      OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrQueueLastChanged indicates the sysUpTime when
         an object in this table was last modified. A Value 0 means that no
         change was made to this row since it was created."
    ::= { tmnxLogApCustRecordQueueEntry 3 }

tmnxLogApCrQueueICounters        OBJECT-TYPE
    SYNTAX      TmnxAccPlcyQICounters
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrQueueICounters specifies the list of ingress
         counters that need to be collected in this custom record.

         At least one of the objects tmnxLogApCrQueueICounters or
         tmnxLogApCrQueueECounters must have a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordQueueEntry 4 }

tmnxLogApCrQueueECounters        OBJECT-TYPE
    SYNTAX      TmnxAccPlcyQECounters
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrQueueECounters specifies the list of egress
         counters that need to be collected in this custom record.

         At least one of the objects tmnxLogApCrQueueICounters or
         tmnxLogApCrQueueECounters must have a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordQueueEntry 5 }

tmnxLogApCrOverrideCntrTable     OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogApCrOverrideCntrEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "The Nokia SROS series tmnxLogApCrOverrideCntrTable allows to create
         custom record counter override information for a given accounting
         policy.

         Rows can only be created for existing accounting policies (as defined
         in tmnxLogApTable)."
    ::= { tmnxLogObjs 22 }

tmnxLogApCrOverrideCntrEntry     OBJECT-TYPE
    SYNTAX      TmnxLogApCrOverrideCntrEntry
    MAX-ACCESS  not-accessible
    STATUS      obsolete
    DESCRIPTION
        "Defines an entry in the tmnxLogApCrOverrideCntrTable. Entries in this
         table are created and destroyed via SNMP Set requests."
    INDEX       {
        tmnxLogApPolicyId,
        tmnxLogApCrOverrideCntrId
    }
    ::= { tmnxLogApCrOverrideCntrTable 1 }

TmnxLogApCrOverrideCntrEntry     ::= SEQUENCE
{
    tmnxLogApCrOverrideCntrId        THsmdaCounterIdOrZero,
    tmnxLogApCrOverrideCntrRowStatus RowStatus,
    tmnxLogApCrOverrideCntrLastChngd TimeStamp,
    tmnxLogApCrOverrideCntrICounters TmnxAccPlcyOICounters,
    tmnxLogApCrOverrideCntrECounters TmnxAccPlcyOECounters
}

tmnxLogApCrOverrideCntrId        OBJECT-TYPE
    SYNTAX      THsmdaCounterIdOrZero (1..8)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrOverrideCntrId specifies the counter group for
         which counters will be collected in this custom record. The counters
         that will be collected are defined in tmnxLogApCrOverrideCntrICounters
         and tmnxLogApCrOverrideCntrECounters."
    ::= { tmnxLogApCrOverrideCntrEntry 1 }

tmnxLogApCrOverrideCntrRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "Row Status of the entry. This allows creation/deletion of rows in this
         table."
    ::= { tmnxLogApCrOverrideCntrEntry 2 }

tmnxLogApCrOverrideCntrLastChngd OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrOverrideCntrLastChngd indicates the sysUpTime
         when an object in this table was last modified. A Value 0 means that
         no change was made to this row since it was created."
    ::= { tmnxLogApCrOverrideCntrEntry 3 }

tmnxLogApCrOverrideCntrICounters OBJECT-TYPE
    SYNTAX      TmnxAccPlcyOICounters
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrOverrideCntrICounters specifies the list of
         ingress counters that need to be collected in this custom record.

         At least one of the objects tmnxLogApCrOverrideCntrICounters or
         tmnxLogApCrOverrideCntrECounters must have a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCrOverrideCntrEntry 4 }

tmnxLogApCrOverrideCntrECounters OBJECT-TYPE
    SYNTAX      TmnxAccPlcyOECounters
    MAX-ACCESS  read-create
    STATUS      obsolete
    DESCRIPTION
        "The value of tmnxLogApCrOverrideCntrECounters specifies the list of
         egress counters that need to be collected in this custom record.

         At least one of the objects tmnxLogApCrOverrideCntrICounters or
         tmnxLogApCrOverrideCntrECounters must have a non-zero value."
    DEFVAL      { {} }
    ::= { tmnxLogApCrOverrideCntrEntry 5 }

tmnxEventPrimaryRoutePref        OBJECT-TYPE
    SYNTAX      INTEGER {
        inband  (1),
        outband (2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventPrimaryRoutePref specifies the primary routing
         preference for traffic generated for SNMP notifications and syslog
         messages.

         A value of 'inband' specifies that the Logging utility will attempt to
         use the Base routing context to send SNMP notifications and syslog
         messages to remote destinations.

         A value of 'outband' specifies that the Logging utility will attempt
         to use the management routing context to send SNMP notifications and
         syslog messages to remote destinations.

         If the remote destination, as specified by tmnxStdDestAddr or
         tmnxSyslogTargetAddr, is not reachable via the routing context
         specified by tmnxEventPrimaryRoutePref, the secondary routing
         preference as specified by tmnxEventSecondaryRoutePref will be
         attempted."
    DEFVAL      { outband }
    ::= { tmnxLogObjs 23 }

tmnxEventSecondaryRoutePref      OBJECT-TYPE
    SYNTAX      INTEGER {
        inband  (1),
        outband (2),
        none    (3)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxEventSecondaryRoutePref specifies the secondary
         routing preference for traffic generated for SNMP notifications and
         syslog messages. The routing context specified by the
         tmnxEventSecondaryRoutePref will be attempted if the remote
         destination was not reachable by the primary routing preference,
         specified by tmnxEventPrimaryRoutePref. The value specified for
         tmnxEventSecondaryRoutePref must be distinct from the value for
         tmnxEventPrimaryRoutePref.

         A value of 'inband' specifies that the Logging utility will attempt to
         use the Base routing context to send SNMP notifications and syslog
         messages to remote destinations.

         A value of 'outband' specifies that the Logging utility will attempt
         to use the management routing context to send SNMP notifications and
         syslog messages to remote destinations.

         A value of 'none' specifies that no attempt will be made to send SNMP
         notifications and syslog messages to remote destinations.

         If the remote destination, as specified by tmnxStdDestAddr or
         tmnxSyslogTargetAddr, is not reachable via the routing contexts
         specified by tmnxEventPrimaryRoutePref and
         tmnxEventSecondaryRoutePref, the Log utility will fail to send SNMP
         notifications and syslog messages to the remote destination."
    DEFVAL      { inband }
    ::= { tmnxLogObjs 24 }

tmnxLogConfigEventsDamped        OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogConfigEventsDamped specifies whether or not the
         module generating tmnxConfigCreate, tmnxConfigDelete, and
         tmnxConfigModify events applies a damping algorithm.

         WARNING: While this event damping is original behavior
         for some modules such as service manager, QoS, and filters it
         can result in the NMS system database being out of sync because
         of missed change events.  On the other hand, if the damping
         is disabled, 'false', it may take much longer for a large
         CLI configuration file to be processed when manually 'exec'ed
         after system bootup."
    DEFVAL      { true }
    ::= { tmnxLogObjs 25 }

tmnxLogEventHistoryObjs          OBJECT IDENTIFIER ::= { tmnxLogObjs 26 }

tmnxLogEventHistGeneralObjs      OBJECT IDENTIFIER ::= { tmnxLogEventHistoryObjs 1 }

tmnxLogExRbkOpTblLastChange      OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogExRbkOpTblLastChange indicates the
         value of sysUpTime at the time of the last modification of a row entry
         in the tmnxLogExecRollbackOpTable."
    ::= { tmnxLogEventHistGeneralObjs 1 }

tmnxLogExRbkOpMaxEntries         OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogExRbkOpMaxEntries specifies the maximum
         number of row entries supported in the tmnxLogExecRollbackOpTable."
    DEFVAL      { 5 }
    ::= { tmnxLogEventHistGeneralObjs 2 }

tmnxLogExecRollbackOpTable       OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogExecRollbackOpEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxLogExecRollbackOpTable provides a history of
         up to the last number of 'exec', 'load', rollback revert, and 'vsd'
         operations specified by the value of tmnxLogExRbkOpMaxEntries.

         The tmnxLogExecRollbackOpTable is intended to provide an aide to
         Network Management Systems (NMS). The 'exec' or 'load' of a large
         configuration file via the system's CLI, a large rollback revert
         operation, or execution of 'vsd' configuration messages will generate
         so many configuration change and other events in a short time that
         neither the SROS's event logging utility nor the NMS can keep up with
         them. This results in the SROS and/or NMS dropping events and requires
         the NMS to perform a costly resynchronization of its management
         database."
    ::= { tmnxLogEventHistoryObjs 3 }

tmnxLogExecRollbackOpEntry       OBJECT-TYPE
    SYNTAX      TmnxLogExecRollbackOpEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row entry in the tmnxLogExecRollbackOpTable. Entries in this
         table are created and deleted by the agent."
    INDEX       { tmnxLogExRbkOpIndex }
    ::= { tmnxLogExecRollbackOpTable 1 }

TmnxLogExecRollbackOpEntry       ::= SEQUENCE
{
    tmnxLogExRbkOpIndex              Unsigned32,
    tmnxLogExRbkOpLastChanged        TimeStamp,
    tmnxLogExRbkOpType               TmnxLogExRbkOperationType,
    tmnxLogExRbkOpStatus             INTEGER,
    tmnxLogExRbkOpBegin              TimeStamp,
    tmnxLogExRbkOpEnd                TimeStamp,
    tmnxLogExRbkOpFile               DisplayString,
    tmnxLogExRbkOpUser               TNamedItemOrEmpty,
    tmnxLogExRbkOpNumEvents          Unsigned32
}

tmnxLogExRbkOpIndex              OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpIndex is a unique value that indicates an
         instance of an exec, load, rollback revert, or vsd operation. Only the
         most recent instances are kept in this table. The maximum number of
         row entries supported in this table is specified by the value of
         tmnxLogExRbkOpMaxEntries."
    ::= { tmnxLogExecRollbackOpEntry 1 }

tmnxLogExRbkOpLastChanged        OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpLastChanged indicates the sysUpTime when an
         object in this table was last modified. A Value 0 means that no change
         was made to this row since it was created."
    ::= { tmnxLogExecRollbackOpEntry 2 }

tmnxLogExRbkOpType               OBJECT-TYPE
    SYNTAX      TmnxLogExRbkOperationType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpType indicates the type of operation this
         row entry represents."
    ::= { tmnxLogExecRollbackOpEntry 3 }

tmnxLogExRbkOpStatus             OBJECT-TYPE
    SYNTAX      INTEGER {
        unknown    (0),
        inProgress (1),
        success    (2),
        failed     (3)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpStatus indicates the status of this exec,
         load, rollback revert, or vsd operation."
    ::= { tmnxLogExecRollbackOpEntry 4 }

tmnxLogExRbkOpBegin              OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpBegin indicates the sysUpTime when the
         exec, load, rollback revert, or vsd operation began."
    ::= { tmnxLogExecRollbackOpEntry 5 }

tmnxLogExRbkOpEnd                OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpEnd indicates the sysUpTime when the exec,
         load, rollback revert, or vsd operation ended. A value of zero (0)
         means that the operation has not completed."
    ::= { tmnxLogExecRollbackOpEntry 6 }

tmnxLogExRbkOpFile               OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpFile indicates the location and name of the
         file used for the exec, load or rollback revert operation, otherwise
         the value of this object is an empty string."
    ::= { tmnxLogExecRollbackOpEntry 7 }

tmnxLogExRbkOpUser               OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpUser indicates the user who initiated the
         exec or rollback revert operation."
    ::= { tmnxLogExecRollbackOpEntry 8 }

tmnxLogExRbkOpNumEvents          OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkOpNumEvents indicates the number of
         row entries in the associated tmnxLogExecRollbackEventTable
         for this exec, load, rollback revert, or vsd operation.
         It is updated only when the exec, load, rollback revert, or vsd
         operation ends.  A value of zero (0) means that the operatio
         has not completed."
    ::= { tmnxLogExecRollbackOpEntry 9 }

tmnxLogExecRollbackEventTable    OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogExecRollbackEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxLogExecRollbackEventTable provides a history
         of mib tables modified or specific events generated during an exec,
         load, rollback revert, or vsd operation."
    ::= { tmnxLogEventHistoryObjs 4 }

tmnxLogExecRollbackEventEntry    OBJECT-TYPE
    SYNTAX      TmnxLogExecRollbackEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row entry in the tmnxLogExecRollbackEventTable. Each row
         entry represents either an SNMP table that has been modified or a
         specific event generated during an exec, load, rollback revert, or vsd
         operation. Entries in this table are created and deleted by the agent."
    INDEX       {
        tmnxLogExRbkOpIndex,
        tmnxLogExRbkEventIndex
    }
    ::= { tmnxLogExecRollbackEventTable 1 }

TmnxLogExecRollbackEventEntry    ::= SEQUENCE
{
    tmnxLogExRbkEventIndex           Unsigned32,
    tmnxLogExRbkEventOID             OBJECT IDENTIFIER
}

tmnxLogExRbkEventIndex           OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkEventIndex is a unique value that indicates
         an instance of an event generated during an exec, load, rollback
         revert, or vsd operation."
    ::= { tmnxLogExecRollbackEventEntry 1 }

tmnxLogExRbkEventOID             OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExRbkEventOID indicates the object identifier of
         either a mib table for which a generic change event was generated or
         the notification object identifier of a specific event notification
         generated during the the exec, load, rollback revert, or vsd
         operation.

         The generic change events are tmnxConfigCreate, tmnxConfigDelete,
         tmnxConfigModify, and tmnxStateChange notifications.  For these
         event types, the value of tmnxLogExRbkEventOID is the object
         identifier specified by the tmnxNotifyEntryOID varbind.

         For specific events generated during an exec, load or rollback revert
         or vsd, the value of this object is the notification object identifier
         itself.

         An object identifier will appear only once in this table."
    ::= { tmnxLogExecRollbackEventEntry 2 }

tmnxLogExRbkNotifyObjects        OBJECT IDENTIFIER ::= { tmnxLogEventHistoryObjs 5 }

tmnxLogExecRollbackOpIndex       OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExecRollbackOpIndex is a unique value that
         indicates a row entry instance of an exec, load, rollback revert,
         or vsd operation in the tmnxLogExecRollbackOpTable.  It is included
         in the 'exec', 'load' and rollback revert start and end notifications."
    ::= { tmnxLogExRbkNotifyObjects 1 }

tmnxLogExecRollbackOpType        OBJECT-TYPE
    SYNTAX      TmnxLogExRbkOperationType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogExecRollbackOpType indicates the type of
         operation being performed. It is included in the 'exec',  'load'
         and rollback revert start and end notifications."
    ::= { tmnxLogExRbkNotifyObjects 2 }

tmnxLogColdStartWaitTime         OBJECT-TYPE
    SYNTAX      Unsigned32 (0..300)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogColdStartWaitTime specifies the time delay that
         must pass before notifying specific CPM applications that a route is
         available after a cold reboot."
    DEFVAL      { 0 }
    ::= { tmnxLogObjs 27 }

tmnxLogRouteRecoveryWaitTime     OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogRouteRecoveryWaitTime specifies the time delay
         that must pass before notifying specific CPM applications after the
         recovery or change of a route during normal operation."
    DEFVAL      { 0 }
    ::= { tmnxLogObjs 28 }

tmnxEhsObjs                      OBJECT IDENTIFIER ::= { tmnxLogObjs 29 }

tmnxEhsGeneralObjs               OBJECT IDENTIFIER ::= { tmnxEhsObjs 1 }

tmnxEhsHandlerTblLastChange      OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsHandlerTblLastChange indicates the
         value of sysUpTime at the time of the last modification of a row in
         the tmnxEhsHandlerTable."
    ::= { tmnxEhsGeneralObjs 1 }

tmnxEhsHandlerMaxEntries         OBJECT-TYPE
    SYNTAX      Unsigned32 (0..5000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsHandlerMaxEntries specifies the maximum
         number of row entries supported in the tmnxEhsHandlerTable."
    DEFVAL      { 1500 }
    ::= { tmnxEhsGeneralObjs 2 }

tmnxEhsHEntryTblLastChange       OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsHEntryTblLastChange indicates the value
         of sysUpTime at the time of the last modification of a row in the
         tmnxEhsHEntryTable."
    ::= { tmnxEhsGeneralObjs 3 }

tmnxEhsHEntryMaxEntries          OBJECT-TYPE
    SYNTAX      Unsigned32 (0..5000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsHEntryMaxEntries specifies the maximum
         number of row entries supported in the tmnxEhsHEntryTable."
    DEFVAL      { 1500 }
    ::= { tmnxEhsGeneralObjs 4 }

tmnxEhsTriggerTblLastChange      OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsTriggerTblLastChange indicates the
         value of sysUpTime at the time of the last modification of a row in
         the tmnxEhsTriggerTable."
    ::= { tmnxEhsGeneralObjs 5 }

tmnxEhsTriggerMaxEntries         OBJECT-TYPE
    SYNTAX      Unsigned32 (0..5000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsTriggerMaxEntries specifies the maximum
         number of rows supported in the tmnxEhsTriggerTable."
    DEFVAL      { 1500 }
    ::= { tmnxEhsGeneralObjs 6 }

tmnxEhsTEntryTblLastChange       OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsTEntryTblLastChange indicates the value
         of sysUpTime at the time of the last modification of a row entry in
         the tmnxEhsTEntryTable."
    ::= { tmnxEhsGeneralObjs 7 }

tmnxEhsTEntryMaxEntries          OBJECT-TYPE
    SYNTAX      Unsigned32 (0..5000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxEhsTEntryMaxEntries specifies the maximum
         number of row entries supported in the tmnxEhsTEntryTable."
    DEFVAL      { 1500 }
    ::= { tmnxEhsGeneralObjs 8 }

tmnxEhsHandlerTable              OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsHandlerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsHandlerTable contains a list of Event Handlers used by the
         Event Handling System (EHS) Event Triggers."
    ::= { tmnxEhsObjs 2 }

tmnxEhsHandlerEntry              OBJECT-TYPE
    SYNTAX      TmnxEhsHandlerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row entry in the tmnxEhsHandlerTable.  Each entry
         contains information about a specific Event Handling System (EHS)
         Event Handler.

         Rows are created and deleted via SNMP SET operations using
         tmnxEhsHandlerRowStatus."
    INDEX       { tmnxEhsHandlerName }
    ::= { tmnxEhsHandlerTable 1 }

TmnxEhsHandlerEntry              ::= SEQUENCE
{
    tmnxEhsHandlerName               TNamedItem,
    tmnxEhsHandlerRowStatus          RowStatus,
    tmnxEhsHandlerDescription        TItemDescription,
    tmnxEhsHandlerLastChange         TimeStamp,
    tmnxEhsHandlerAdminStatus        TmnxAdminState,
    tmnxEhsHandlerOperStatus         TmnxOperState
}

tmnxEhsHandlerName               OBJECT-TYPE
    SYNTAX      TNamedItem
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerName specifies the name of an Event
         Handling System (EHS) Event Handler represented by this row in the
         tmnxEhsHandlerTable."
    ::= { tmnxEhsHandlerEntry 1 }

tmnxEhsHandlerRowStatus          OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerRowStatus specifies
         the row status.  It allows rows to be created
         and deleted in the tmnxEhsHandlerTable.

         If any associated rows exist in the tmnxEhsHEntryTable,
         'destroy' will fail.  All associated rows must be
         destroyed first."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxEhsHandlerEntry 2 }

tmnxEhsHandlerDescription        OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerDescription specifies a user provided
         description string for an EHS Handler. It can consist of any
         printable, seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''H }
    ::= { tmnxEhsHandlerEntry 3 }

tmnxEhsHandlerLastChange         OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerLastChange indicates the time this row
         entry was last changed."
    ::= { tmnxEhsHandlerEntry 4 }

tmnxEhsHandlerAdminStatus        OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerAdminStatus specifies the administrative
         state of the EHS Event Handler."
    DEFVAL      { outOfService }
    ::= { tmnxEhsHandlerEntry 5 }

tmnxEhsHandlerOperStatus         OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerOperStatus indicates the operational state
         of the EHS Event Handler."
    ::= { tmnxEhsHandlerEntry 6 }

tmnxEhsHandlerStatsTable         OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsHandlerStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsHandlerStatsTable contains operational data for Event
         handlers used by the EHS Event Triggers."
    ::= { tmnxEhsObjs 3 }

tmnxEhsHandlerStatsEntry         OBJECT-TYPE
    SYNTAX      TmnxEhsHandlerStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsHandlerStatsTable. Each row contains
         operational information about a specific EHS Event Handler.

         Rows are created and deleted by the system as rows are created and
         deleted in the tmnxEhsHandlerTable."
    AUGMENTS    { tmnxEhsHandlerEntry }
    ::= { tmnxEhsHandlerStatsTable 1 }

TmnxEhsHandlerStatsEntry         ::= SEQUENCE
{
    tmnxEhsHandlerStatsSuccess       Unsigned32,
    tmnxEhsHandlerStatsErrNoEntry    Unsigned32,
    tmnxEhsHandlerStatsErrAdmStatus  Unsigned32
}

tmnxEhsHandlerStatsSuccess       OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerStatsSuccess indicates the number of times
         the EHS system triggers a handler, which can take corresponding action
         specified in handler's entries"
    ::= { tmnxEhsHandlerStatsEntry 1 }

tmnxEhsHandlerStatsErrNoEntry    OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerStatsErrNoEntry indicates the number of
         times the EHS system triggers a handler, which can not take
         corresponding action as there is no handler's entry specifying an
         operation to perform."
    ::= { tmnxEhsHandlerStatsEntry 2 }

tmnxEhsHandlerStatsErrAdmStatus  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHandlerStatsErrAdmStatus indicates the number of
         times the EHS system triggers a handler, which can not take
         corresponding action due to admin state of the handler.

         The handler may be out-of-service due to tmnxEhsHandlerAdminStatus
         being set to 'outOfService (3)'."
    ::= { tmnxEhsHandlerStatsEntry 3 }

tmnxEhsHEntryTable               OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsHEntryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsHEntryTable contains a list of Event Handler Entries in an
         EHS Event Handler."
    ::= { tmnxEhsObjs 4 }

tmnxEhsHEntryEntry               OBJECT-TYPE
    SYNTAX      TmnxEhsHEntryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsHEntryTable.  Each row
         contains information about a specific Handler Entry.

         Rows are created and deleted via SNMP SET operations using
         tmnxEhsHEntryRowStatus."
    INDEX       {
        tmnxEhsHandlerName,
        tmnxEhsHEntryId
    }
    ::= { tmnxEhsHEntryTable 1 }

TmnxEhsHEntryEntry               ::= SEQUENCE
{
    tmnxEhsHEntryId                  Unsigned32,
    tmnxEhsHEntryRowStatus           RowStatus,
    tmnxEhsHEntryDescription         TItemDescription,
    tmnxEhsHEntryLastChange          TimeStamp,
    tmnxEhsHEntryAdminStatus         TmnxAdminState,
    tmnxEhsHEntryOperStatus          TmnxOperState,
    tmnxEhsHEntryScriptPlcyName      TNamedItemOrEmpty,
    tmnxEhsHEntryScriptPlcyOwner     TNamedItemOrEmpty,
    tmnxEhsHEntryMinDelay            Unsigned32,
    tmnxEhsHEntryLastExecuted        TimeStamp
}

tmnxEhsHEntryId                  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryId specifies the index of an Event Entry in
         the EHS Event Handler indicated by the value of tmnxEhsHandlerName."
    ::= { tmnxEhsHEntryEntry 1 }

tmnxEhsHEntryRowStatus           OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryRowStatus specifies
         the row status.  It allows rows to be created
         and deleted in the tmnxEhsHEntryTable.

         If an associated row does not exist in the tmnxEhsHandlerTable, a
         attempt to create a row will fail."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxEhsHEntryEntry 2 }

tmnxEhsHEntryDescription         OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryDescription specifies a user provided
         description string for EHS Event Handler Entry. It can consist of any
         printable, seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''H }
    ::= { tmnxEhsHEntryEntry 3 }

tmnxEhsHEntryLastChange          OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryLastChange indicates the time this row was
         last changed."
    ::= { tmnxEhsHEntryEntry 4 }

tmnxEhsHEntryAdminStatus         OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryAdminStatus specifies the administrative
         state of the EHS Event Handler Entry."
    DEFVAL      { inService }
    ::= { tmnxEhsHEntryEntry 5 }

tmnxEhsHEntryOperStatus          OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryOperStatus indicates the operational state
         of the EHS Event Handler Entry."
    ::= { tmnxEhsHEntryEntry 6 }

tmnxEhsHEntryScriptPlcyName      OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryScriptPlcyName in combination with the value
         of tmnxEhsHEntryScriptPlcyOwner specifies the script policy that can
         be launched from this tmnxEhsHEntryTable row. The zero-length string
         may be used to point to a non-existing script policy."
    DEFVAL      { ''H }
    ::= { tmnxEhsHEntryEntry 7 }

tmnxEhsHEntryScriptPlcyOwner     OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryScriptPlcyOwner in combination with the
         value of tmnxEhsHEntryScriptPlcyName specifies the script policy that
         can be launched from this tmnxEhsHEntryTable row. The zero-length
         string may be used to point to a non-existing script policy."
    DEFVAL      { ''H }
    ::= { tmnxEhsHEntryEntry 8 }

tmnxEhsHEntryMinDelay            OBJECT-TYPE
    SYNTAX      Unsigned32 (0..604800)
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryMinDelay specifies the minimum
         time, in seconds, between executions of the script policy
         specified by this EHS Event Handler Entry.  A '0' value means
         no delay is imposed."
    DEFVAL      { 0 }
    ::= { tmnxEhsHEntryEntry 9 }

tmnxEhsHEntryLastExecuted        OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryLastExecuted indicates the time when handler
         entry launch execution of action."
    ::= { tmnxEhsHEntryEntry 10 }

tmnxEhsHEntryStatsTable          OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsHEntryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsHEntryStatsTable contains operational data for Event
         Handler Entries used by an EHS Event Handler."
    ::= { tmnxEhsObjs 5 }

tmnxEhsHEntryStatsEntry          OBJECT-TYPE
    SYNTAX      TmnxEhsHEntryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row entry in the tmnxEhsHEntryStatsTable. Each row contains
         operational information about a specific EHS Event Handler Entry.

         Rows are created and deleted by the system as rows are created and
         deleted in the tmnxEhsHEntryTable."
    AUGMENTS    { tmnxEhsHEntryEntry }
    ::= { tmnxEhsHEntryStatsTable 1 }

TmnxEhsHEntryStatsEntry          ::= SEQUENCE
{
    tmnxEhsHEntryStatsLaunchSuccess  Unsigned32,
    tmnxEhsHEntryStatsErrMinDelay    Unsigned32,
    tmnxEhsHEntryStatsErrLaunch      Unsigned32,
    tmnxEhsHEntryStatsErrAdmStatus   Unsigned32
}

tmnxEhsHEntryStatsLaunchSuccess  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryStatsLaunchSuccess indicates the number of
         successfully queued scripts by EHS handler entry."
    ::= { tmnxEhsHEntryStatsEntry 1 }

tmnxEhsHEntryStatsErrMinDelay    OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryStatsErrMinDelay indicates the number of
         cancelled script executions due to tmnxEhsHEntryMinDelay."
    ::= { tmnxEhsHEntryStatsEntry 2 }

tmnxEhsHEntryStatsErrLaunch      OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryStatsErrLaunch indicates the number of
         cancelled script executions due to launch failure."
    ::= { tmnxEhsHEntryStatsEntry 3 }

tmnxEhsHEntryStatsErrAdmStatus   OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsHEntryStatsErrAdmStatus indicates the number of
         cancelled script executions due to admin state of the handler entry.

         The handler entry may be out-of-service due to
         tmnxEhsHEntryAdminStatus being set to 'outOfService (3)'."
    ::= { tmnxEhsHEntryStatsEntry 4 }

tmnxEhsTriggerTable              OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsTriggerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsTriggerTable contains a list of Event Triggers used by the
         Event Handling System (EHS)."
    ::= { tmnxEhsObjs 6 }

tmnxEhsTriggerEntry              OBJECT-TYPE
    SYNTAX      TmnxEhsTriggerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsTriggerTable.  Each row
         contains information about a specific Event Handling
         system (EHS) Event Trigger.

         Rows are created and deleted via SNMP SET operations using
         tmnxEhsTriggerRowStatus."
    INDEX       {
        tmnxEventAppIndex,
        tmnxEventID
    }
    ::= { tmnxEhsTriggerTable 1 }

TmnxEhsTriggerEntry              ::= SEQUENCE
{
    tmnxEhsTriggerRowStatus          RowStatus,
    tmnxEhsTriggerDescription        TItemDescription,
    tmnxEhsTriggerLastChange         TimeStamp,
    tmnxEhsTriggerAdminStatus        TmnxAdminState,
    tmnxEhsTriggerOperStatus         TmnxOperState
}

tmnxEhsTriggerRowStatus          OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerRowStatus specifies
         the row status.  It allows rows to be created
         and deleted in the tmnxEhsTriggerTable.

         If any associated rows exist in the tmnxEhsTEntryTable, 'destroy' will
         fail with an 'inconsistentValue' error. All associated rows in the
         tmnxEhsTEntryTable must be destroyed first."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxEhsTriggerEntry 1 }

tmnxEhsTriggerDescription        OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerDescription specifies a user provided
         description string for an EHS Event Trigger. It can consist of any
         printable, seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''H }
    ::= { tmnxEhsTriggerEntry 2 }

tmnxEhsTriggerLastChange         OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerLastChange indicates the time this row was
         last changed."
    ::= { tmnxEhsTriggerEntry 3 }

tmnxEhsTriggerAdminStatus        OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerAdminStatus specifies the administrative
         state of the EHS Event Trigger."
    DEFVAL      { outOfService }
    ::= { tmnxEhsTriggerEntry 4 }

tmnxEhsTriggerOperStatus         OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerOperStatus indicates the operational state
         of the EHS Event Trigger."
    ::= { tmnxEhsTriggerEntry 5 }

tmnxEhsTriggerStatsTable         OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsTriggerStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsTriggerStatsTable contains operational data for Event
         Triggers used by the Event Handling System (EHS)."
    ::= { tmnxEhsObjs 7 }

tmnxEhsTriggerStatsEntry         OBJECT-TYPE
    SYNTAX      TmnxEhsTriggerStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsTriggerStatsTable. Each row contains
         operational information about a specific EHS Event Trigger.

         Rows are created and deleted by the system as rows are created and
         deleted in the tmnxEhsTriggerTable."
    AUGMENTS    { tmnxEhsTriggerEntry }
    ::= { tmnxEhsTriggerStatsTable 1 }

TmnxEhsTriggerStatsEntry         ::= SEQUENCE
{
    tmnxEhsTriggerStatsSuccess       Unsigned32,
    tmnxEhsTriggerStatsErrNoEntry    Unsigned32,
    tmnxEhsTriggerStatsErrAdmStatus  Unsigned32
}

tmnxEhsTriggerStatsSuccess       OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerStatsSuccess indicates the number of not
         ignored logger event occurrences associated with EHS trigger."
    ::= { tmnxEhsTriggerStatsEntry 1 }

tmnxEhsTriggerStatsErrNoEntry    OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerStatsErrNoEntry indicates the number of
         ignored logger event occurrences associated with EHS trigger. Event is
         ignored due to no trigger entry configured for this trigger."
    ::= { tmnxEhsTriggerStatsEntry 2 }

tmnxEhsTriggerStatsErrAdmStatus  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTriggerStatsErrAdmStatus indicates the number of
         ignored logger event occurrences associated with EHS trigger. Event is
         ignored due to admin state of the trigger.

         The trigger may be out-of-service due to tmnxEhsTriggerAdminStatus
         being set to 'outOfService (3)'."
    ::= { tmnxEhsTriggerStatsEntry 3 }

tmnxEhsTEntryTable               OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsTEntryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxEhsTEntryTable contains a list of Event Trigger Entries in an
         EHS Event Trigger."
    ::= { tmnxEhsObjs 8 }

tmnxEhsTEntryEntry               OBJECT-TYPE
    SYNTAX      TmnxEhsTEntryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsTEntryTable.  Each row
         contains information about a specific EHS Event Trigger
         Entry.

         Rows are created and deleted via SNMP SET operations using
         tmnxEhsTEntryRowStatus."
    INDEX       {
        tmnxEventAppIndex,
        tmnxEventID,
        tmnxEhsTEntryId
    }
    ::= { tmnxEhsTEntryTable 1 }

TmnxEhsTEntryEntry               ::= SEQUENCE
{
    tmnxEhsTEntryId                  Unsigned32,
    tmnxEhsTEntryRowStatus           RowStatus,
    tmnxEhsTEntryDescription         TItemDescription,
    tmnxEhsTEntryLastChange          TimeStamp,
    tmnxEhsTEntryAdminStatus         TmnxAdminState,
    tmnxEhsTEntryOperStatus          TmnxOperState,
    tmnxEhsTEntryLogFilterId         TmnxLogFilterId,
    tmnxEhsTEntryHandlerName         TNamedItemOrEmpty,
    tmnxEhsTEntryDebounceVal         Unsigned32,
    tmnxEhsTEntryDebounceTime        Unsigned32
}

tmnxEhsTEntryId                  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryId specifies the index of a Trigger Entry in
         the EHS Event Trigger indicated by the value of tmnxEventAppIndex and
         tmnxEventID."
    ::= { tmnxEhsTEntryEntry 1 }

tmnxEhsTEntryRowStatus           OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryRowStatus specifies
         the row status.  It allows entries to be created
         and deleted in the tmnxEhsTEntryTable.

         If an associated row does not exist in the tmnxEhsTriggerTable, an
         attempt to create this row entry will fail."
    REFERENCE
        "See definition of RowStatus in RFC 2579, 'Textual
         Conventions for SMIv2.'"
    ::= { tmnxEhsTEntryEntry 2 }

tmnxEhsTEntryDescription         OBJECT-TYPE
    SYNTAX      TItemDescription
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryDescription specifies a user provided
         description string for EHS Event Trigger Entry. It can consist of any
         printable, seven-bit ASCII characters up to 80 characters in length."
    DEFVAL      { ''H }
    ::= { tmnxEhsTEntryEntry 3 }

tmnxEhsTEntryLastChange          OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryLastChange indicates the time this row entry
         was last changed."
    ::= { tmnxEhsTEntryEntry 4 }

tmnxEhsTEntryAdminStatus         OBJECT-TYPE
    SYNTAX      TmnxAdminState
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryAdminStatus specifies the administrative
         state of the EHS Event Trigger Entry."
    DEFVAL      { inService }
    ::= { tmnxEhsTEntryEntry 5 }

tmnxEhsTEntryOperStatus          OBJECT-TYPE
    SYNTAX      TmnxOperState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryOperStatus indicates the operational state
         of the EHS Event Trigger Entry."
    ::= { tmnxEhsTEntryEntry 6 }

tmnxEhsTEntryLogFilterId         OBJECT-TYPE
    SYNTAX      TmnxLogFilterId
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryLogFilterId specifies the logger filter
         to apply to a generated logger event.  If the logger filter match
         succeeds, the actions indicated in the associated EHS Event Handler,
         indicated by the value of tmnxEhsTEntryHandlerName, are applied.

         A value of 0 indicates there is no associated logger filter and
         therefore the associated EHS Event Handler is always applied."
    DEFVAL      { 0 }
    ::= { tmnxEhsTEntryEntry 7 }

tmnxEhsTEntryHandlerName         OBJECT-TYPE
    SYNTAX      TNamedItemOrEmpty
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryHandlerName specifies the EHS Event Handler
         to be applied.  The zero-length string may be used to point to a
         non-existing Event Handler."
    DEFVAL      { ''H }
    ::= { tmnxEhsTEntryEntry 8 }

tmnxEhsTEntryDebounceVal         OBJECT-TYPE
    SYNTAX      Unsigned32 (0 | 2..15)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryDebounceVal specifies the number of times an
         event has to occur within a specific time window given by
         tmnxEhsTEntryDebounceTime for EHS Event to trigger a response."
    DEFVAL      { 0 }
    ::= { tmnxEhsTEntryEntry 9 }

tmnxEhsTEntryDebounceTime        OBJECT-TYPE
    SYNTAX      Unsigned32 (0..604800)
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryDebounceTime specifies the time window
         within which a specific event must occur more than the value specified
         by tmnxEhsTEntryDebounceVal for EHS to trigger a response."
    DEFVAL      { 0 }
    ::= { tmnxEhsTEntryEntry 10 }

tmnxEhsTEntryStatsTable          OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxEhsTEntryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxEhsTEntryStatsTable contains operational
         data for Event Trigger Entries used by an EHS Event Trigger."
    ::= { tmnxEhsObjs 9 }

tmnxEhsTEntryStatsEntry          OBJECT-TYPE
    SYNTAX      TmnxEhsTEntryStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines a row in the tmnxEhsTEntryStatsTable. Each row contains
         operational information about a specific EHS Event Trigger Entry.

         Rows are created and deleted by the system as row are created and
         deleted in the tmnxEhsTEntryTable."
    AUGMENTS    { tmnxEhsTEntryEntry }
    ::= { tmnxEhsTEntryStatsTable 1 }

TmnxEhsTEntryStatsEntry          ::= SEQUENCE
{
    tmnxEhsTEntryStatsFilterMatch    Unsigned32,
    tmnxEhsTEntryStatsFilterFail     Unsigned32,
    tmnxEhsTEntryStatsErrAdminStatus Unsigned32,
    tmnxEhsTEntryStatsErrFilter      Unsigned32,
    tmnxEhsTEntryStatsErrHandler     Unsigned32,
    tmnxEhsTEntryStatsTriggerCount   Unsigned32,
    tmnxEhsTEntryStatsDebounce       Unsigned32
}

tmnxEhsTEntryStatsFilterMatch    OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsFilterMatch indicates the number of
         times a filter, for the specified trigger entry, matches an logger
         event."
    ::= { tmnxEhsTEntryStatsEntry 1 }

tmnxEhsTEntryStatsFilterFail     OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsFilterFail indicates the number of
         times a filter, for the specified trigger entry, does not match an
         logger event."
    ::= { tmnxEhsTEntryStatsEntry 2 }

tmnxEhsTEntryStatsErrAdminStatus OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsErrAdminStatus indicates the number of
         times the logger event will be ignored due to admin state of EHS
         trigger entry.

         The trigger entry may be out-of-service due to
         tmnxEhsTEntryAdminStatus being set to 'outOfService (3)'."
    ::= { tmnxEhsTEntryStatsEntry 3 }

tmnxEhsTEntryStatsErrFilter      OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsErrFilter indicates the number of times
         the logger event will be ignored due to filter is not operational or
         is not configured in EHS trigger entry."
    ::= { tmnxEhsTEntryStatsEntry 4 }

tmnxEhsTEntryStatsErrHandler     OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsErrHandler indicates the number of
         times the logger event will be ignored due to filter is not
         operational or is not configured in EHS trigger entry."
    ::= { tmnxEhsTEntryStatsEntry 5 }

tmnxEhsTEntryStatsTriggerCount   OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxEhsTEntryStatsTriggerCount indicates the number of
         times script execution is triggered after filter match."
    ::= { tmnxEhsTEntryStatsEntry 6 }

tmnxEhsTEntryStatsDebounce       OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the tmnxEhsTEntryStatsDebounce indicates the number of
         times script is not executed due to debounce rule."
    ::= { tmnxEhsTEntryStatsEntry 7 }

tmnxLogCliSubscrTable            OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogCliSubscrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The tmnxLogCliSubscrTable contains information about CLI user session
         subscriptions to logs."
    ::= { tmnxLogObjs 30 }

tmnxLogCliSubscrEntry            OBJECT-TYPE
    SYNTAX      TmnxLogCliSubscrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each conceptual row represents information about a subscription of a
         particular CLI user session to a particular log.

         Entries in this table are created and destroyed automatically by the
         system."
    INDEX       {
        tmnxLogCliSubscrSession,
        tmnxLogCliSubscrLog
    }
    ::= { tmnxLogCliSubscrTable 1 }

TmnxLogCliSubscrEntry            ::= SEQUENCE
{
    tmnxLogCliSubscrSession          Unsigned32,
    tmnxLogCliSubscrLog              TmnxLogIdIndex,
    tmnxLogCliSubscrType             INTEGER,
    tmnxLogCliSubscrUser             TNamedItem,
    tmnxLogCliSubscrUserLoginTime    DateAndTime,
    tmnxLogCliSubscrUserIpAddrType   InetAddressType,
    tmnxLogCliSubscrUserIpAddr       InetAddress
}

tmnxLogCliSubscrSession          OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogCliSubscrSession indicates the unique
         identifier of a CLI user session."
    ::= { tmnxLogCliSubscrEntry 1 }

tmnxLogCliSubscrLog              OBJECT-TYPE
    SYNTAX      TmnxLogIdIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogCliSubscrLog indicates the unique identifier of an
         event stream log.

         It refers to a conceptual row in the tmnxLogIdTable."
    ::= { tmnxLogCliSubscrEntry 2 }

tmnxLogCliSubscrType             OBJECT-TYPE
    SYNTAX      INTEGER {
        telnet  (1),
        console (2),
        ssh     (4)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogCliSubscrType indicates the type of
         session."
    ::= { tmnxLogCliSubscrEntry 3 }

tmnxLogCliSubscrUser             OBJECT-TYPE
    SYNTAX      TNamedItem
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogCliSubscrUser indicates the name of the
         user associated with the CLI session."
    ::= { tmnxLogCliSubscrEntry 4 }

tmnxLogCliSubscrUserLoginTime    OBJECT-TYPE
    SYNTAX      DateAndTime (SIZE (11))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogCliSubscrUserLoginTime indicates the time the user
         logged in."
    ::= { tmnxLogCliSubscrEntry 5 }

tmnxLogCliSubscrUserIpAddrType   OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogCliSubscrUserIpAddrType indicates the address type
         of tmnxLogCliSubscrUserIpAddr."
    ::= { tmnxLogCliSubscrEntry 6 }

tmnxLogCliSubscrUserIpAddr       OBJECT-TYPE
    SYNTAX      InetAddress (SIZE (0|4|16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of the object tmnxLogCliSubscrUserIpAddr indicates
         the  IP address of the user."
    ::= { tmnxLogCliSubscrEntry 7 }

tmnxLogApCustRecordPolicerTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF TmnxLogApCustRecordPolicerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Nokia SROS series tmnxLogApCustRecordPolicerTable allows to create
         custom record policer information for a given accounting policy. Rows
         can only be created for existing accounting policies (as defined in
         tmnxLogApTable)."
    ::= { tmnxLogObjs 31 }

tmnxLogApCustRecordPolicerEntry  OBJECT-TYPE
    SYNTAX      TmnxLogApCustRecordPolicerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A conceptual row contains the specification of the counters that must
         be collected for a particular policer and accounting policy.

         A conceptual row can be created and destroyed by means of the
         tmnxLogApCrPolicerRowStatus object."
    INDEX       {
        tmnxLogApPolicyId,
        tmnxLogApCrPolicerId
    }
    ::= { tmnxLogApCustRecordPolicerTable 1 }

TmnxLogApCustRecordPolicerEntry  ::= SEQUENCE
{
    tmnxLogApCrPolicerId             Unsigned32,
    tmnxLogApCrPolicerLastChanged    TimeStamp,
    tmnxLogApCrPolicerRowStatus      RowStatus,
    tmnxLogApCrPolicerICounters      TmnxAccPlcyPolicerICounters,
    tmnxLogApCrPolicerECounters      TmnxAccPlcyPolicerECounters
}

tmnxLogApCrPolicerId             OBJECT-TYPE
    SYNTAX      Unsigned32 (1..63)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrPolicerId specifies the policer ID for which
         counters will be collected in this custom record.

         The counters that will be collected are defined in
         tmnxLogApCrPolicerICounters and tmnxLogApCrPolicerECounters."
    ::= { tmnxLogApCustRecordPolicerEntry 1 }

tmnxLogApCrPolicerLastChanged    OBJECT-TYPE
    SYNTAX      TimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrPolicerLastChanged indicates the sysUpTime
         when an object in this table was last modified.

         A value of zero means that no change was made to this row since it was
         created."
    ::= { tmnxLogApCustRecordPolicerEntry 2 }

tmnxLogApCrPolicerRowStatus      OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Row Status of the entry. This allows creation/deletion of rows in this
         table."
    ::= { tmnxLogApCustRecordPolicerEntry 3 }

tmnxLogApCrPolicerICounters      OBJECT-TYPE
    SYNTAX      TmnxAccPlcyPolicerICounters
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrPolicerICounters specifies the list of ingress
         counters that need to be collected in this custom record."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordPolicerEntry 4 }

tmnxLogApCrPolicerECounters      OBJECT-TYPE
    SYNTAX      TmnxAccPlcyPolicerECounters
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The value of tmnxLogApCrPolicerECounters specifies the list of egress
         counters that need to be collected in this custom record."
    DEFVAL      { {} }
    ::= { tmnxLogApCustRecordPolicerEntry 5 }

tmnxLogConformance               OBJECT IDENTIFIER ::= { tmnxSRConfs 12 }

tmnxLogCompliances               OBJECT IDENTIFIER ::= { tmnxLogConformance 1 }

tmnxLogV4v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 4.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV4v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogGroup,
            tmnxSnmpTrapGroup,
            tmnxLogEventsR2r1Group,
            tmnxLogNotificationR3r0Group
        }
    ::= { tmnxLogCompliances 4 }

tmnxLogV5v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 5.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV5v0Group
        }
    ::= { tmnxLogCompliances 5 }

tmnxLogV6v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 6.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group
        }
    ::= { tmnxLogCompliances 6 }

tmnxLogV6v1Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 6.1 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogAccountingPolicyV6v1Group
        }
    ::= { tmnxLogCompliances 7 }

tmnxLogV7v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 7.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogRoutePreferenceV7v0Group
        }
    ::= { tmnxLogCompliances 8 }

tmnxLogV9v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 9.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group
        }
    ::= { tmnxLogCompliances 9 }

tmnxLogV8v0Compliance            MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 7.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group
        }
    ::= { tmnxLogCompliances 10 }

tmnxLogV10v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 10.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup
        }
    ::= { tmnxLogCompliances 11 }

tmnxLogV11v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 11.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogEventsV11v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup,
            tmnxLogApExtGroup,
            tmnxLogAppRouteNotifV10v0Group,
            tmnxLogApV11v0Group,
            tmnxLogApCrV11v0Group
        }
    ::= { tmnxLogCompliances 12 }

tmnxLogV13v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 13.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyV6v1Group,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogEventsV11v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup,
            tmnxLogApExtGroup,
            tmnxLogAppRouteNotifV10v0Group,
            tmnxLogApV11v0Group,
            tmnxLogApCrV11v0Group,
            tmnxLogFilterMsgV13v0Group,
            tmnxLogEHSV13v0Group
        }
    ::= { tmnxLogCompliances 13 }

tmnxLogV14v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 14.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogEHSV14v0Group
        }
    ::= { tmnxLogCompliances 14 }

tmnxLogV15v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 15.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogEventsV11v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup,
            tmnxLogApExtGroup,
            tmnxLogAppRouteNotifV10v0Group,
            tmnxLogApV11v0Group,
            tmnxLogApCrV11v0Group,
            tmnxLogFilterMsgV13v0Group,
            tmnxLogEHSV13v0Group,
            tmnxLogEHSV14v0Group,
            tmnxLogPythonGroup,
            tmnxLogToSessionGroup,
            tmnxLogToNetconfGroup
        }
    ::= { tmnxLogCompliances 15 }

tmnxLogV16v0Compliance           MODULE-COMPLIANCE
    STATUS      obsolete
    DESCRIPTION
        "The compliance statement for revision 16.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogEventsV11v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup,
            tmnxLogApExtGroup,
            tmnxLogAppRouteNotifV10v0Group,
            tmnxLogApV11v0Group,
            tmnxLogApCrV11v0Group,
            tmnxLogFilterMsgV13v0Group,
            tmnxLogEHSV13v0Group,
            tmnxLogEHSV14v0Group,
            tmnxLogPythonGroup,
            tmnxLogToSessionGroup,
            tmnxLogToNetconfGroup,
            tmnxLogEventsV16v0Group,
            tmnxLogCliSubscrGroup
        }
    ::= { tmnxLogCompliances 16 }

tmnxLogV19v0Compliance           MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for revision 19.0 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogGlobalGroup,
            tmnxLogV5v0Group,
            tmnxLogAccountingPolicyGroup,
            tmnxLogAccountingPolicyCRV7v0Group,
            tmnxLogFileIdGroup,
            tmnxLogSyslogV5v0Group,
            tmnxSnmpTrapV5v0Group,
            tmnxSnmpTrapDestV6v0Group,
            tmnxSnmpSetErrsGroup,
            tmnxLogEventsV5v0Group,
            tmnxLogEventsV11v0Group,
            tmnxLogNotificationV6v0Group,
            tmnxLogNotificationV9v0Group,
            tmnxLogRoutePreferenceV7v0Group,
            tmnxLogEventDampedV8v0Group,
            tmnxLogApV9v0Group,
            tmnxLogExRbkOpGroup,
            tmnxLogApExtGroup,
            tmnxLogAppRouteNotifV10v0Group,
            tmnxLogApV11v0Group,
            tmnxLogApCrV11v0Group,
            tmnxLogFilterMsgV13v0Group,
            tmnxLogEHSV13v0Group,
            tmnxLogEHSV14v0Group,
            tmnxLogPythonGroup,
            tmnxLogToSessionGroup,
            tmnxLogToNetconfGroup,
            tmnxLogEventsV16v0Group,
            tmnxLogCliSubscrGroup,
            tmnxLogAcctPolicyCrV19v0Group,
            tmnxLogApV19v0Group
        }
    ::= { tmnxLogCompliances 17 }

tmnxLogV20v0Compliance           MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for revision 20 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxLogNameGroup,
            tmnxLogFilterNameGroup,
            tmnxLogSnmpTrapGroupNameGroup,
            tmnxLogFilterParamsNameGroup,
            tmnxSyslogTargetNameGroup
        }
    ::= { tmnxLogCompliances 18 }

tmnxLogV21v0Compliance           MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for revision 21 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxSyslogTlsClntProfilNameGroup,
            tmnxLogFileNameGroup
        }
    ::= { tmnxLogCompliances 19 }

tmnxLogV22v0Compliance           MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for revision 22 of TIMETRA-LOG-MIB."
    MODULE
        MANDATORY-GROUPS {
            tmnxSnmpTrapDestV22v0Group
        }
    ::= { tmnxLogCompliances 20 }

tmnxLogGroups                    OBJECT IDENTIFIER ::= { tmnxLogConformance 2 }

tmnxLogGlobalGroup               OBJECT-GROUP
    OBJECTS     {
        tmnxLogMaxLogs
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of event logging
         capabilities on Nokia SROS series systems."
    ::= { tmnxLogGroups 1 }

tmnxLogAccountingPolicyGroup     OBJECT-GROUP
    OBJECTS     {
        tmnxLogApRowStatus,
        tmnxLogApStorageType,
        tmnxLogApAdminStatus,
        tmnxLogApOperStatus,
        tmnxLogApInterval,
        tmnxLogApDescription,
        tmnxLogApDefault,
        tmnxLogApRecord,
        tmnxLogApToFileId,
        tmnxLogApPortType,
        tmnxLogApAlign
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of accounting policies
         capabilities on Nokia SROS series systems."
    ::= { tmnxLogGroups 3 }

tmnxLogFileIdGroup               OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileIdRowStatus,
        tmnxLogFileIdStorageType,
        tmnxLogFileIdRolloverTime,
        tmnxLogFileIdRetainTime,
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdDescription,
        tmnxLogFileIdLogType,
        tmnxLogFileIdLogId,
        tmnxLogFileIdPathName,
        tmnxLogFileIdCreateTime,
        tmnxLogFileIdBackupLoc
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log File destinations on
         Nokia SROS series systems."
    ::= { tmnxLogGroups 4 }

tmnxLogSyslogGroup               OBJECT-GROUP
    OBJECTS     {
        tmnxSyslogTargetRowStatus,
        tmnxSyslogTargetDescription,
        tmnxSyslogTargetAddress,
        tmnxSyslogTargetUdpPort,
        tmnxSyslogTargetFacility,
        tmnxSyslogTargetSeverity,
        tmnxSyslogTargetMessagePrefix,
        tmnxSyslogTargetMessagesDropped
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log Syslog destinations
         on Nokia SROS series systems."
    ::= { tmnxLogGroups 5 }

tmnxSnmpTrapGroup                OBJECT-GROUP
    OBJECTS     {
        tmnxStgRowStatus,
        tmnxStgDescription,
        tmnxStgVersion,
        tmnxStgNotifyCommunity,
        tmnxStgSecurityLevel
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log SNMP notification
         destinations on Nokia SROS series systems."
    ::= { tmnxLogGroups 6 }

tmnxLogEventsR2r1Group           OBJECT-GROUP
    OBJECTS     {
        tmnxEventAppName,
        tmnxEventName,
        tmnxEventSeverity,
        tmnxEventControl,
        tmnxEventCounter,
        tmnxEventDropCount,
        tmnxEventReset,
        tmnxEventTest
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log Events on Nokia SROS
         series systems release 2.1."
    ::= { tmnxLogGroups 10 }

tmnxLogNotifyObjsR3r0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileDeletedLogId,
        tmnxLogFileDeletedFileId,
        tmnxLogFileDeletedLogType,
        tmnxLogFileDeletedLocation,
        tmnxLogFileDeletedName,
        tmnxLogFileDeletedCreateTime,
        tmnxLogTraceErrorTitle,
        tmnxLogTraceErrorMessage
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log notifications on
         Nokia SROS series systems."
    ::= { tmnxLogGroups 13 }

tmnxLogNotificationR3r0Group     NOTIFICATION-GROUP
    NOTIFICATIONS {
        tmnxLogSpaceContention,
        tmnxLogAdminLocFailed,
        tmnxLogBackupLocFailed,
        tmnxLogFileRollover,
        tmnxLogFileDeleted,
        tmnxTestEvent,
        tmnxLogTraceError
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of notifications supporting the Log feature on Nokia SROS
         series systems release 3.0."
    ::= { tmnxLogGroups 14 }

tmnxLogV4v0Group                 OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdRowStatus,
        tmnxLogIdStorageType,
        tmnxLogIdAdminStatus,
        tmnxLogIdOperStatus,
        tmnxLogIdDescription,
        tmnxLogIdFilterId,
        tmnxLogIdSource,
        tmnxLogIdDestination,
        tmnxLogIdFileId,
        tmnxLogIdSyslogId,
        tmnxLogIdMaxMemorySize,
        tmnxLogIdConsoleSession,
        tmnxLogIdForwarded,
        tmnxLogIdDropped,
        tmnxLogIdTimeFormat,
        tmnxLogFilterRowStatus,
        tmnxLogFilterDescription,
        tmnxLogFilterDefaultAction,
        tmnxLogFilterInUse,
        tmnxLogFilterParamsRowStatus,
        tmnxLogFilterParamsDescription,
        tmnxLogFilterParamsAction,
        tmnxLogFilterParamsApplication,
        tmnxLogFilterParamsApplOperator,
        tmnxLogFilterParamsNumber,
        tmnxLogFilterParamsNumberOperator,
        tmnxLogFilterParamsSeverity,
        tmnxLogFilterParamsSeverityOperator,
        tmnxLogFilterParamsSubject,
        tmnxLogFilterParamsSubjectOperator,
        tmnxLogFilterParamsSubjectRegexp
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of event logs on Nokia SROS
         series systems."
    ::= { tmnxLogGroups 15 }

tmnxSnmpSetErrsGroup             OBJECT-GROUP
    OBJECTS     {
        tmnxSnmpSetErrsMax,
        tmnxSseVersion,
        tmnxSseSeverityLevel,
        tmnxSseModuleId,
        tmnxSseModuleName,
        tmnxSseErrorCode,
        tmnxSseErrorName,
        tmnxSseErrorMsg,
        tmnxSseExtraText,
        tmnxSseTimestamp
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of SNMP SET failure error
         messages."
    ::= { tmnxLogGroups 16 }

tmnxLogEventsV5v0Group           OBJECT-GROUP
    OBJECTS     {
        tmnxEventAppName,
        tmnxEventName,
        tmnxEventSeverity,
        tmnxEventControl,
        tmnxEventCounter,
        tmnxEventDropCount,
        tmnxEventReset,
        tmnxEventThrottle,
        tmnxEventTest,
        tmnxEventThrottleLimit,
        tmnxEventThrottleInterval
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log Events on Nokia SROS
         series systems release 5.0."
    ::= { tmnxLogGroups 17 }

tmnxLogNotifyObjsV5v0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileDeletedLogId,
        tmnxLogFileDeletedFileId,
        tmnxLogFileDeletedLogType,
        tmnxLogFileDeletedLocation,
        tmnxLogFileDeletedName,
        tmnxLogFileDeletedCreateTime,
        tmnxLogTraceErrorTitle,
        tmnxLogTraceErrorMessage,
        tmnxLogThrottledEventID,
        tmnxLogThrottledEvents,
        tmnxSysLogTargetId,
        tmnxSysLogTargetProblemDescr
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log notifications on
         Nokia SROS series systems release 5.0."
    ::= { tmnxLogGroups 18 }

tmnxLogNotificationV5v0Group     NOTIFICATION-GROUP
    NOTIFICATIONS {
        tmnxLogSpaceContention,
        tmnxLogAdminLocFailed,
        tmnxLogBackupLocFailed,
        tmnxLogFileRollover,
        tmnxLogFileDeleted,
        tmnxTestEvent,
        tmnxLogTraceError,
        tmnxLogEventThrottled,
        tmnxSysLogTargetProblem
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of notifications supporting the Log feature on Nokia SROS
         series systems release 5.0."
    ::= { tmnxLogGroups 19 }

tmnxLogSyslogV5v0Group           OBJECT-GROUP
    OBJECTS     {
        tmnxSyslogTargetRowStatus,
        tmnxSyslogTargetDescription,
        tmnxSyslogTargetUdpPort,
        tmnxSyslogTargetFacility,
        tmnxSyslogTargetSeverity,
        tmnxSyslogTargetMessagePrefix,
        tmnxSyslogTargetMessagesDropped,
        tmnxSyslogTargetAddrType,
        tmnxSyslogTargetAddr
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log Syslog destinations
         on Nokia SROS series systems release 5.0."
    ::= { tmnxLogGroups 20 }

tmnxSnmpTrapV5v0Group            OBJECT-GROUP
    OBJECTS     {
        tmnxSnmpTrapLogDescription,
        tmnxStdRowStatus,
        tmnxStdRowLastChanged,
        tmnxStdDestAddrType,
        tmnxStdDestAddr,
        tmnxStdDestPort,
        tmnxStdDescription,
        tmnxStdVersion,
        tmnxStdNotifyCommunity,
        tmnxStdSecurityLevel,
        tmnxStdMaxTargets
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log SNMP notification
         destinations on Nokia SROS series systems for release 5.0."
    ::= { tmnxLogGroups 21 }

tmnxLogV5v0Group                 OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdRowStatus,
        tmnxLogIdStorageType,
        tmnxLogIdAdminStatus,
        tmnxLogIdOperStatus,
        tmnxLogIdDescription,
        tmnxLogIdFilterId,
        tmnxLogIdSource,
        tmnxLogIdDestination,
        tmnxLogIdFileId,
        tmnxLogIdSyslogId,
        tmnxLogIdMaxMemorySize,
        tmnxLogIdConsoleSession,
        tmnxLogIdForwarded,
        tmnxLogIdDropped,
        tmnxLogIdTimeFormat,
        tmnxLogFilterRowStatus,
        tmnxLogFilterDescription,
        tmnxLogFilterDefaultAction,
        tmnxLogFilterInUse,
        tmnxLogFilterParamsRowStatus,
        tmnxLogFilterParamsDescription,
        tmnxLogFilterParamsAction,
        tmnxLogFilterParamsApplication,
        tmnxLogFilterParamsApplOperator,
        tmnxLogFilterParamsNumber,
        tmnxLogFilterParamsNumberOperator,
        tmnxLogFilterParamsSeverity,
        tmnxLogFilterParamsSeverityOperator,
        tmnxLogFilterParamsSubject,
        tmnxLogFilterParamsSubjectOperator,
        tmnxLogFilterParamsSubjectRegexp,
        tmnxLogFilterParamsRouter,
        tmnxLogFilterParamsRouterOperator,
        tmnxLogFilterParamsRouterRegexp
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of event logs on Nokia SROS
         series systems in release 5.0."
    ::= { tmnxLogGroups 22 }

tmnxLogObsoleteObjsV5v0Group     OBJECT-GROUP
    OBJECTS     {
        tmnxSyslogTargetAddress,
        tmnxStgRowStatus,
        tmnxStgDescription,
        tmnxStgVersion,
        tmnxStgNotifyCommunity,
        tmnxStgSecurityLevel
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of TiMOS logs obsoleted on
         Nokia SROS series systems in release 5.0."
    ::= { tmnxLogGroups 23 }

tmnxLogNotifyObjsV6v0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileDeletedLogId,
        tmnxLogFileDeletedFileId,
        tmnxLogFileDeletedLogType,
        tmnxLogFileDeletedLocation,
        tmnxLogFileDeletedName,
        tmnxLogFileDeletedCreateTime,
        tmnxLogTraceErrorTitle,
        tmnxLogTraceErrorMessage,
        tmnxLogThrottledEventID,
        tmnxLogThrottledEvents,
        tmnxSysLogTargetId,
        tmnxSysLogTargetProblemDescr,
        tmnxLogNotifyApInterval,
        tmnxStdReplayStartEvent,
        tmnxStdReplayEndEvent
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of Log notifications on
         Nokia SROS series systems release 6.0."
    ::= { tmnxLogGroups 24 }

tmnxLogNotificationV6v0Group     NOTIFICATION-GROUP
    NOTIFICATIONS {
        tmnxLogSpaceContention,
        tmnxLogAdminLocFailed,
        tmnxLogBackupLocFailed,
        tmnxLogFileRollover,
        tmnxLogFileDeleted,
        tmnxTestEvent,
        tmnxLogTraceError,
        tmnxLogEventThrottled,
        tmnxSysLogTargetProblem,
        tmnxLogAccountingDataLoss,
        tmnxStdEventsReplayed
    }
    STATUS      current
    DESCRIPTION
        "The group of notifications supporting the Log feature on Nokia SROS
         series systems release 6.0."
    ::= { tmnxLogGroups 25 }

tmnxSnmpTrapDestV6v0Group        OBJECT-GROUP
    OBJECTS     {
        tmnxStdReplay,
        tmnxStdReplayStart,
        tmnxStdReplayLastTime
    }
    STATUS      current
    DESCRIPTION
        "The group of objects added to support SNMP trap destinations in the
         Nokia SROS series systems release 6.0."
    ::= { tmnxLogGroups 26 }

tmnxLogAccountingPolicyV6v1Group OBJECT-GROUP
    OBJECTS     {
        tmnxLogApDefaultInterval
    }
    STATUS      obsolete
    DESCRIPTION
        "The group of objects supporting management of accounting policies
         capabilities on Nokia SROS series systems release 6.1."
    ::= { tmnxLogGroups 27 }

tmnxLogAccountingPolicyCRV7v0Group OBJECT-GROUP
    OBJECTS     {
        tmnxLogApCrLastChanged,
        tmnxLogApCrSignChangeDelta,
        tmnxLogApCrSignChangeQueue,
        tmnxLogApCrSignChangeQICounters,
        tmnxLogApCrSignChangeQECounters,
        tmnxLogApCrSignChangeAACounters,
        tmnxLogApCrAACounters,
        tmnxLogApCrQueueRowStatus,
        tmnxLogApCrQueueLastChanged,
        tmnxLogApCrQueueICounters,
        tmnxLogApCrQueueECounters
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting the creation of a custom record inside
         a accounting policy on Nokia SROS series systems."
    ::= { tmnxLogGroups 28 }

tmnxLogRoutePreferenceV7v0Group  OBJECT-GROUP
    OBJECTS     {
        tmnxEventPrimaryRoutePref,
        tmnxEventSecondaryRoutePref
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting routing preferences of Log Events on
         Nokia SROS series systems release 7.0."
    ::= { tmnxLogGroups 29 }

tmnxLogNotifyObjsV8v0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileDeletedLogId,
        tmnxLogFileDeletedFileId,
        tmnxLogFileDeletedLogType,
        tmnxLogFileDeletedLocation,
        tmnxLogFileDeletedName,
        tmnxLogFileDeletedCreateTime,
        tmnxLogTraceErrorTitle,
        tmnxLogTraceErrorSubject,
        tmnxLogTraceErrorMessage,
        tmnxLogThrottledEventID,
        tmnxLogThrottledEvents,
        tmnxSysLogTargetId,
        tmnxSysLogTargetProblemDescr,
        tmnxLogNotifyApInterval,
        tmnxStdReplayStartEvent,
        tmnxStdReplayEndEvent
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log notifications on
         Nokia SROS series systems release 8.0."
    ::= { tmnxLogGroups 30 }

tmnxLogNotificationV9v0Group     NOTIFICATION-GROUP
    NOTIFICATIONS {
        tmnxLogEventOverrun
    }
    STATUS      current
    DESCRIPTION
        "The group of notifications supporting the Log feature on Nokia SROS
         series systems added in release 9.0."
    ::= { tmnxLogGroups 31 }

tmnxLogEventDampedV8v0Group      OBJECT-GROUP
    OBJECTS     {
        tmnxLogConfigEventsDamped
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting damping of change events on Nokia SROS
         series systems added in release 8.0r7."
    ::= { tmnxLogGroups 32 }

tmnxLogApV9v0Group               OBJECT-GROUP
    OBJECTS     {
        tmnxLogApDataLossCount,
        tmnxLogApLastDataLossTimeStamp
    }
    STATUS      current
    DESCRIPTION
        "The group of objects extending the application log table on Nokia SROS
         series systems added in release 9.0."
    ::= { tmnxLogGroups 33 }

tmnxLogExRbkOpGroup              OBJECT-GROUP
    OBJECTS     {
        tmnxLogExRbkOpTblLastChange,
        tmnxLogExRbkOpMaxEntries,
        tmnxLogExRbkOpLastChanged,
        tmnxLogExRbkOpType,
        tmnxLogExRbkOpStatus,
        tmnxLogExRbkOpBegin,
        tmnxLogExRbkOpEnd,
        tmnxLogExRbkOpFile,
        tmnxLogExRbkOpUser,
        tmnxLogExRbkOpNumEvents,
        tmnxLogExRbkEventOID
    }
    STATUS      current
    DESCRIPTION
        "The group of objects managing exec and rollback revert event history."
    ::= { tmnxLogGroups 34 }

tmnxLogNotifyObjsV10v0Group      OBJECT-GROUP
    OBJECTS     {
        tmnxLogExecRollbackOpIndex
    }
    STATUS      current
    DESCRIPTION
        "The group of accessible-for-notify objects added to Nokia SROS series
         systems release 10.0."
    ::= { tmnxLogGroups 35 }

tmnxLogApExtGroup                OBJECT-GROUP
    OBJECTS     {
        tmnxLogApToFileType
    }
    STATUS      current
    DESCRIPTION
        "The group of objects extending the accounting policy table on Nokia
         SROS series systems."
    ::= { tmnxLogGroups 36 }

tmnxLogAppRouteNotifV10v0Group   OBJECT-GROUP
    OBJECTS     {
        tmnxLogColdStartWaitTime,
        tmnxLogRouteRecoveryWaitTime
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting notifications on completion of wait
         time after cold reboot and route recovery on Nokia SROS series systems
         release 10.0."
    ::= { tmnxLogGroups 37 }

tmnxLogApV11v0Group              OBJECT-GROUP
    OBJECTS     {
        tmnxLogApIncludeSystemInfo
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log Accounting Policy
         feature on Nokia SROS series systems in release 11.0."
    ::= { tmnxLogGroups 38 }

tmnxLogEventsV11v0Group          OBJECT-GROUP
    OBJECTS     {
        tmnxEventSpecThrottle,
        tmnxEventSpecThrottleLimit,
        tmnxEventSpecThrottleIntval,
        tmnxEventSpecThrottleDef,
        tmnxEventSpecThrottleLimitDef,
        tmnxEventSpecThrottleIntvalDef
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log Events added for
         Nokia SROS series systems release 11.0."
    ::= { tmnxLogGroups 40 }

tmnxLogApCrV11v0Group            OBJECT-GROUP
    OBJECTS     {
        tmnxLogApCrAASubAttributes
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log Accounting Policy
         Custom Record feature on Nokia SROS series systems in release 11.0."
    ::= { tmnxLogGroups 41 }

tmnxLogFilterMsgV13v0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxLogFilterParamsMsg,
        tmnxLogFilterParamsMsgOperator,
        tmnxLogFilterParamsMsgRegexp
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of event logs on Nokia SROS
         series systems in release 13.0."
    ::= { tmnxLogGroups 42 }

tmnxLogNotifyObjsV13v0Group      OBJECT-GROUP
    OBJECTS     {
        tmnxLogExecRollbackOpType
    }
    STATUS      current
    DESCRIPTION
        "The group of accessible-for-notify objects added to Nokia SROS series
         systems release 13.0."
    ::= { tmnxLogGroups 43 }

tmnxLogEHSV13v0Group             OBJECT-GROUP
    OBJECTS     {
        tmnxEhsHandlerTblLastChange,
        tmnxEhsHandlerMaxEntries,
        tmnxEhsHandlerRowStatus,
        tmnxEhsHandlerDescription,
        tmnxEhsHandlerLastChange,
        tmnxEhsHandlerAdminStatus,
        tmnxEhsHandlerOperStatus,
        tmnxEhsHandlerStatsSuccess,
        tmnxEhsHandlerStatsErrNoEntry,
        tmnxEhsHandlerStatsErrAdmStatus,
        tmnxEhsHEntryTblLastChange,
        tmnxEhsHEntryMaxEntries,
        tmnxEhsHEntryRowStatus,
        tmnxEhsHEntryDescription,
        tmnxEhsHEntryLastChange,
        tmnxEhsHEntryAdminStatus,
        tmnxEhsHEntryOperStatus,
        tmnxEhsHEntryScriptPlcyName,
        tmnxEhsHEntryScriptPlcyOwner,
        tmnxEhsHEntryMinDelay,
        tmnxEhsHEntryLastExecuted,
        tmnxEhsHEntryStatsLaunchSuccess,
        tmnxEhsHEntryStatsErrMinDelay,
        tmnxEhsHEntryStatsErrLaunch,
        tmnxEhsHEntryStatsErrAdmStatus,
        tmnxEhsTriggerTblLastChange,
        tmnxEhsTriggerMaxEntries,
        tmnxEhsTriggerRowStatus,
        tmnxEhsTriggerDescription,
        tmnxEhsTriggerLastChange,
        tmnxEhsTriggerAdminStatus,
        tmnxEhsTriggerOperStatus,
        tmnxEhsTriggerStatsSuccess,
        tmnxEhsTriggerStatsErrNoEntry,
        tmnxEhsTriggerStatsErrAdmStatus,
        tmnxEhsTEntryTblLastChange,
        tmnxEhsTEntryMaxEntries,
        tmnxEhsTEntryRowStatus,
        tmnxEhsTEntryDescription,
        tmnxEhsTEntryLastChange,
        tmnxEhsTEntryAdminStatus,
        tmnxEhsTEntryOperStatus,
        tmnxEhsTEntryLogFilterId,
        tmnxEhsTEntryHandlerName,
        tmnxEhsTEntryStatsFilterMatch,
        tmnxEhsTEntryStatsFilterFail,
        tmnxEhsTEntryStatsErrAdminStatus,
        tmnxEhsTEntryStatsErrFilter,
        tmnxEhsTEntryStatsErrHandler,
        tmnxEhsTEntryStatsTriggerCount
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting the Event Handling System (EHS)
         feature on Nokia SROS series systems in release 13.0."
    ::= { tmnxLogGroups 44 }

tmnxLogNotifyObjsV14v0Group      OBJECT-GROUP
    OBJECTS     {
        tmnxEhsHEntryMinDelayInterval
    }
    STATUS      current
    DESCRIPTION
        "The group of accessible-for-notify objects added to Nokia SROS series
         systems release 14.0."
    ::= { tmnxLogGroups 45 }

tmnxLogEHSV14v0Group             OBJECT-GROUP
    OBJECTS     {
        tmnxEhsTEntryDebounceVal,
        tmnxEhsTEntryDebounceTime,
        tmnxEhsTEntryStatsDebounce
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting the Event Handling System (EHS)
         feature on Nokia SROS series systems in release 14.0."
    ::= { tmnxLogGroups 46 }

tmnxLogPythonGroup               OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdPythonPolicy
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting Python for log messages on Nokia SROS
         series systems."
    ::= { tmnxLogGroups 50 }

tmnxLogToSessionGroup            OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdOperDestination
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting log messages on Nokia SROS series
         systems."
    ::= { tmnxLogGroups 51 }

tmnxLogObsoleteObjsV15v0Group    OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdConsoleSession,
        tmnxLogApDefaultInterval
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of TiMOS logs obsoleted on
         Nokia SROS series systems in release 15.0."
    ::= { tmnxLogGroups 52 }

tmnxLogToNetconfGroup            OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdNetconfStream
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting NETCONF log messages on Nokia SROS
         series systems."
    ::= { tmnxLogGroups 53 }

tmnxLogEventsV16v0Group          OBJECT-GROUP
    OBJECTS     {
        tmnxEventRepeat
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting management of Log Events added for
         Nokia SROS series systems release 16.0."
    ::= { tmnxLogGroups 54 }

tmnxLogCliSubscrGroup            OBJECT-GROUP
    OBJECTS     {
        tmnxLogCliSubscrType,
        tmnxLogCliSubscrUser,
        tmnxLogCliSubscrUserLoginTime,
        tmnxLogCliSubscrUserIpAddrType,
        tmnxLogCliSubscrUserIpAddr
    }
    STATUS      current
    DESCRIPTION
        "The group of objects that support read-only access to CLI users
         subscriptions to event log messages on Nokia SROS series systems."
    ::= { tmnxLogGroups 55 }

tmnxLogAcctPolicyCrV19v0Group    OBJECT-GROUP
    OBJECTS     {
        tmnxLogApCrPolicerLastChanged,
        tmnxLogApCrPolicerRowStatus,
        tmnxLogApCrPolicerICounters,
        tmnxLogApCrPolicerECounters,
        tmnxLogApCrSignChangePolicer,
        tmnxLogApCrSignChangePICounters,
        tmnxLogApCrSignChangePECounters
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting custom records inside a accounting
         policy on Nokia SROS series systems added in release 19."
    ::= { tmnxLogGroups 56 }

tmnxLogApV19v0Group              OBJECT-GROUP
    OBJECTS     {
        tmnxLogApAlign
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log Accounting Policy
         feature on Nokia SROS series systems in release 19.0."
    ::= { tmnxLogGroups 57 }

tmnxLogNameGroup                 OBJECT-GROUP
    OBJECTS     {
        tmnxLogIdName
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log Id Vs Name feature
         on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 58 }

tmnxLogFilterNameGroup           OBJECT-GROUP
    OBJECTS     {
        tmnxLogFilterName
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log Filter Id Vs Name
         feature on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 59 }

tmnxLogSnmpTrapGroupNameGroup    OBJECT-GROUP
    OBJECTS     {
        snmpNotifyId
    }
    STATUS      current
    DESCRIPTION
        "The group of additonal objects supporting the Log Snmp-trap-group Id
         vs Name feature on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 60 }

tmnxLogFilterParamsNameGroup     OBJECT-GROUP
    OBJECTS     {
        tmnxLogFilterParamsName
    }
    STATUS      current
    DESCRIPTION
        "The group of additonal objects supporting the Log Filter Entry Id vs
         Name feature on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 61 }

tmnxSyslogTargetNameGroup        OBJECT-GROUP
    OBJECTS     {
        tmnxSyslogTargetName
    }
    STATUS      current
    DESCRIPTION
        "The group of additonal objects supporting the Log Syslog Id vs Name
         feature on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 63 }

tmnxSyslogTlsClntProfilNameGroup OBJECT-GROUP
    OBJECTS     {
        tmnxSyslogTlsClntProfileName
    }
    STATUS      current
    DESCRIPTION
        "The group of additonal objects supporting the Log Syslog over TLS
         feature on Nokia SROS series systems in release 20."
    ::= { tmnxLogGroups 64 }

tmnxLogApObsoleteObjsV21v0Group  OBJECT-GROUP
    OBJECTS     {
        tmnxLogApCrSignChangeOCntr,
        tmnxLogApCrSignChangeOECounters,
        tmnxLogApCrSignChangeOICounters,
        tmnxLogApCrOverrideCntrRowStatus,
        tmnxLogApCrOverrideCntrLastChngd,
        tmnxLogApCrOverrideCntrICounters,
        tmnxLogApCrOverrideCntrECounters
    }
    STATUS      current
    DESCRIPTION
        "The group of objects supporting custom record counter override
         information obsoleted on Nokia SROS series systems in release 21.0."
    ::= { tmnxLogGroups 65 }

tmnxLogFileNameGroup             OBJECT-GROUP
    OBJECTS     {
        tmnxLogFileIdName
    }
    STATUS      current
    DESCRIPTION
        "The group of additional objects supporting the Log File Id Vs Name
         feature on Nokia SROS series systems in release 21."
    ::= { tmnxLogGroups 66 }

tmnxSnmpTrapDestV22v0Group       OBJECT-GROUP
    OBJECTS     {
        tmnxStdDyingGasp
    }
    STATUS      current
    DESCRIPTION
        "The group of objects added to support SNMP trap destinations in the
         Nokia SROS series systems release 22.0."
    ::= { tmnxLogGroups 67 }

tmnxLogNotifyPrefix              OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 12 }

tmnxLogNotifications             OBJECT IDENTIFIER ::= { tmnxLogNotifyPrefix 0 }

tmnxLogSpaceContention           NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileIdRolloverTime,
        tmnxLogFileIdRetainTime,
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdBackupLoc,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdLogId,
        tmnxLogFileIdLogType
    }
    STATUS      current
    DESCRIPTION
        "Generated when space contention occurs on the compact flash where
         a log or accounting file creation is being attempted.  Space contention
         exists if:
              Insufficient space is available on the compact flash to create
              a file of the same size as the file being rolled over.

              The first file of this type is being created and less than
              10% of the total compact flash space is available.

              A write operation on a log or accounting file is denied due to
              lack of space."
    ::= { tmnxLogNotifications 1 }

tmnxLogAdminLocFailed            NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdBackupLoc,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdLogId,
        tmnxLogFileIdLogType
    }
    STATUS      current
    DESCRIPTION
        "Generated when an attempt to create a log or accounting file at the
         location specified by tmnxLogFileIdAdminLocation has failed. Indicates
         that the backup location, if specified, will be used."
    ::= { tmnxLogNotifications 2 }

tmnxLogBackupLocFailed           NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdBackupLoc,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdLogId,
        tmnxLogFileIdLogType
    }
    STATUS      current
    DESCRIPTION
        "Generated when an attempt to create a log or accounting file at the
         location specified by tmnxLogFileIdBackupLoc has failed."
    ::= { tmnxLogNotifications 3 }

tmnxLogFileRollover              NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileIdRolloverTime,
        tmnxLogFileIdRetainTime,
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdBackupLoc,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdLogId,
        tmnxLogFileIdLogType,
        tmnxLogFileIdPathName,
        tmnxLogFileIdCreateTime
    }
    STATUS      current
    DESCRIPTION
        "Generated when an event log or accounting policy file's
         rollover time has expired.  The file located as indicated
         by the value of tmnxLogFileIdOperLocation is closed and a new
         file is created as specified by tmnxLogFileIdAdminLocation
         and tmnxLogFileIdBackupLoc."
    ::= { tmnxLogNotifications 4 }

tmnxLogFileDeleted               NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileDeletedLogId,
        tmnxLogFileDeletedFileId,
        tmnxLogFileDeletedLogType,
        tmnxLogFileDeletedLocation,
        tmnxLogFileDeletedName,
        tmnxLogFileDeletedCreateTime
    }
    STATUS      current
    DESCRIPTION
        "Generated when a closed event log or accounting policy file has been
         deleted as part of the space contention cleanup."
    ::= { tmnxLogNotifications 5 }

tmnxTestEvent                    NOTIFICATION-TYPE
    OBJECTS     {
        sysDescr,
        sysObjectID
    }
    STATUS      current
    DESCRIPTION
        "The tmnxTestEvent notification is generated when the object
         tmnxEventTest is set to a value of 'doAction'.  This event can
         be used to test that remote log destinations such as syslog and
         snmp trap destinations are configured correctly."
    ::= { tmnxLogNotifications 6 }

tmnxLogTraceError                NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogTraceErrorTitle,
        tmnxLogTraceErrorMessage,
        tmnxLogTraceErrorSubject
    }
    STATUS      current
    DESCRIPTION
        "[CAUSE] The tmnxLogTraceError notification is generated when a
         critical level trace error has been detected by the software. There
         are multiple triggers for such a trace error.

         [EFFECT] Effect varies depending on the specific trigger.

         [RECOVERY] Contact Nokia Support."
    ::= { tmnxLogNotifications 7 }

tmnxLogEventThrottled            NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogThrottledEventID,
        tmnxLogThrottledEvents
    }
    STATUS      current
    DESCRIPTION
        "A tmnxLogEventThrottled notification is generated at the end of the
         throttling interval when one or more events are dropped because the
         throttling limit was reached for that interval."
    ::= { tmnxLogNotifications 8 }

tmnxSysLogTargetProblem          NOTIFICATION-TYPE
    OBJECTS     {
        tmnxSysLogTargetId,
        tmnxSysLogTargetProblemDescr
    }
    STATUS      current
    DESCRIPTION
        "A tmnxSysLogTargetProblem notification is generated when a problem is
         encountered when trying to deliver data to the syslog destination
         identified by the tmnxSysLogTargetId."
    ::= { tmnxLogNotifications 9 }

tmnxLogAccountingDataLoss        NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogFileIdRolloverTime,
        tmnxLogFileIdRetainTime,
        tmnxLogFileIdAdminLocation,
        tmnxLogFileIdBackupLoc,
        tmnxLogFileIdOperLocation,
        tmnxLogFileIdLogId,
        tmnxLogNotifyApInterval
    }
    STATUS      current
    DESCRIPTION
        "A tmnxLogAccountingDataLoss notification is generated
         when an accounting file is still being written to
         when the next interval ends.  The collection of
         statistics for the past interval is immediately
         stopped and collection is started for the next
         interval.  There are missing records in the file
         for this past interval."
    ::= { tmnxLogNotifications 10 }

tmnxStdEventsReplayed            NOTIFICATION-TYPE
    OBJECTS     {
        tmnxStdDestAddrType,
        tmnxStdDestAddr,
        tmnxStdReplayStartEvent,
        tmnxStdReplayEndEvent,
        tmnxStdReplayStart
    }
    STATUS      current
    DESCRIPTION
        "A tmnxStdEventsReplayed notification is generated when
         an SNMP trap target address is added to the RTM (tmnxVRtrID)
         following a period when the address had been removed.
         The value of tmnxStdReplayStartEvent is the SNMP notification
         request ID of the first event that was replayed.  The value
         of tmnxStdReplayEndEvent is the SNMP notification request ID of the
         last missed event that was replayed.  The value of
         tmnxStdReplayStart is the request ID of the first event for
         which there was no route to the trap target address."
    ::= { tmnxLogNotifications 11 }

tmnxLogEventOverrun              NOTIFICATION-TYPE
    OBJECTS     {
        tmnxLogThrottledEventID,
        tmnxLogThrottledEvents
    }
    STATUS      current
    DESCRIPTION
        "[CAUSE] A tmnxLogEventOverrun notification is generated
         at the end of the overrun throttling interval when one or more
         events of the type specified by tmnxLogThrottledEventID were
         dropped because the logger input stream's input queue limit
         was exceeded.  The overrun throttling interval begins when the
         input queue limit is first exceeded and ends when the number of
         events in the input queue has dropped below an internal low
         watermark.  At that point a tmnxLogEventOverrun notification is
         generated for each event type that had one or more     events dropped
         because of the input queue overrun. The number of dropped events
         is specified by tmnxLogThrottledEvents.

         [EFFECT] Logger events have been dropped and were not sent to any
         log destination.  tmnxEventDropCount has been incremented for
         each event dropped because of input queue overrun.

         [RECOVERY] The specific event information of dropped events
         cannot be recovered.  The frequency of input queue overruns
         can be lessened by configuring as few event logs as possible,
         especially those going to remote destinations such as file,
         syslog and snmp notification logs."
    ::= { tmnxLogNotifications 12 }

END