plugin_name: charts.d.plugin
modules:
  - meta:
      plugin_name: charts.d.plugin
      module_name: apcupsd
      monitored_instance:
        name: APC UPS
        link: "https://www.apc.com"
        categories:
          - data-collection.ups
        icon_filename: "apc.svg"
      related_resources:
        integrations:
          list: []
      info_provided_to_referring_integrations:
        description: ""
      keywords:
        - ups
        - apc
        - power
        - supply
        - battery
        - apcupsd
      most_popular: false
    overview:
      data_collection:
        metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics."
        method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics."
      supported_platforms:
        include: []
        exclude: []
      multi_instance: false
      additional_permissions:
        description: ""
      default_behavior:
        auto_detection:
          description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility."
        limits:
          description: ""
        performance_impact:
          description: ""
    setup:
      prerequisites:
        list:
          - title: "Install charts.d plugin"
            description: |
              If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed.
          - title: "Required software"
            description: "Make sure the `apcaccess` and `apcupsd` are installed and running."
      configuration:
        file:
          name: charts.d/apcupsd.conf
        options:
          description: |
            The config file is sourced by the charts.d plugin. It's a standard bash file.
            
            The following collapsed table contains all the options that can be configured for the apcupsd collector.
          folding:
            title: "Config options"
            enabled: true
          list:
            - name: apcupsd_sources
              description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it.
              default_value: "127.0.0.1:3551"
              required: false
            - name: apcupsd_timeout
              description: How long to wait for apcupsd to respond.
              default_value: 3
              required: false
            - name: apcupsd_update_every
              description: The data collection frequency. If unset, will inherit the netdata update frequency.
              default_value: 1
              required: false
            - name: apcupsd_priority
              description: The charts priority on the dashboard.
              default_value: 90000
              required: false
            - name: apcupsd_retries
              description: The number of retries to do in case of failure before disabling the collector.
              default_value: 10
              required: false
        examples:
          folding:
            enabled: false
            title: "Config"
          list:
            - name: Multiple apcupsd sources
              description: Specify a multiple apcupsd sources along with a custom update interval
              config: |
                # add all your APC UPSes in this array - uncomment it too
                declare -A apcupsd_sources=(
                    ["local"]="127.0.0.1:3551",
                    ["remote"]="1.2.3.4:3551"
                )
                
                # how long to wait for apcupsd to respond
                #apcupsd_timeout=3
                
                # the data collection frequency
                # if unset, will inherit the netdata update frequency
                apcupsd_update_every=5
                
                # the charts priority on the dashboard
                #apcupsd_priority=90000
                
                # the number of retries to do in case of failure
                # before disabling the module
                #apcupsd_retries=10
    troubleshooting:
      problems:
        list: []
    alerts:
      - name: apcupsd_ups_charge
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.charge
        info: average UPS charge over the last minute
        os: "*"
      - name: apcupsd_10min_ups_load
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.load
        info: average UPS load over the last 10 minutes
        os: "*"
      - name: apcupsd_last_collected_secs
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.load
        info: number of seconds since the last successful data collection
      - name: apcupsd_selftest_warning
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.selftest
        info: self-test failed due to insufficient battery capacity or due to overload.
      - name: apcupsd_status_onbatt
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS has switched to battery power because the input power has failed
      - name: apcupsd_status_overload
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS is overloaded and cannot supply enough power to the load
      - name: apcupsd_status_lowbatt
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS battery is low and needs to be recharged
      - name: apcupsd_status_replacebatt
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS battery has reached the end of its lifespan and needs to be replaced
      - name: apcupsd_status_nobatt
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS has no battery
      - name: apcupsd_status_commlost
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
        metric: apcupsd.status
        info: APC UPS communication link is lost
    metrics:
      folding:
        title: Metrics
        enabled: false
      description: ""
      availability: []
      scopes:
        - name: ups
          description: "Metrics related to UPS. Each UPS provides its own set of the following metrics."
          labels: []
          metrics:
            - name: apcupsd.charge
              description: UPS Charge
              unit: "percentage"
              chart_type: area
              dimensions:
                - name: charge
            - name: apcupsd.battery.voltage
              description: UPS Battery Voltage
              unit: "Volts"
              chart_type: line
              dimensions:
                - name: voltage
                - name: nominal
            - name: apcupsd.input.voltage
              description: UPS Input Voltage
              unit: "Volts"
              chart_type: line
              dimensions:
                - name: voltage
                - name: min
                - name: max
            - name: apcupsd.output.voltage
              description: UPS Output Voltage
              unit: "Volts"
              chart_type: line
              dimensions:
                - name: absolute
                - name: nominal
            - name: apcupsd.input.frequency
              description: UPS Input Voltage
              unit: "Hz"
              chart_type: line
              dimensions:
                - name: frequency
            - name: apcupsd.load
              description: UPS Load
              unit: "percentage"
              chart_type: area
              dimensions:
                - name: load
            - name: apcupsd.load_usage
              description: UPS Load Usage
              unit: "Watts"
              chart_type: area
              dimensions:
                - name: load
            - name: apcupsd.temperature
              description: UPS Temperature
              unit: "Celsius"
              chart_type: line
              dimensions:
                - name: temp
            - name: apcupsd.time
              description: UPS Time Remaining
              unit: "Minutes"
              chart_type: area
              dimensions:
                - name: time
            - name: apcupsd.online
              description: UPS ONLINE flag
              unit: "boolean"
              chart_type: line
              dimensions:
                - name: online
            - name: apcupsd.selftest
              description: UPS Self-Test status
              unit: status
              chart_type: line
              dimensions:
                - name: OK
                - name: NO
                - name: BT
                - name: NG
            - name: apcupsd.status
              description: UPS Status
              unit: status
              chart_type: line
              dimensions:
                - name: ONLINE
                - name: ONBATT
                - name: OVERLOAD
                - name: LOWBATT
                - name: REPLACEBATT
                - name: NOBATT
                - name: SLAVE
                - name: SLAVEDOWN
                - name: COMMLOST
                - name: CAL
                - name: TRIM
                - name: BOOST
                - name: SHUTTING_DOWN