src/CubeServer-app/cubeserver_app/__init__.py
Function static_cache_buster
has a Cognitive Complexity of 18 (exceeds 5 allowed). Consider refactoring. Open
Open
def static_cache_buster(endpoint, values):
if "." in endpoint and "filename" in values:
(bp_name, vf_name) = endpoint.rsplit(".", 1)
else:
(bp_name, vf_name) = (None, endpoint)
- Read upRead up
Cognitive Complexity
Cognitive Complexity is a measure of how difficult a unit of code is to intuitively understand. Unlike Cyclomatic Complexity, which determines how difficult your code will be to test, Cognitive Complexity tells you how difficult your code will be to read and comprehend.
A method's cognitive complexity is based on a few simple rules:
- Code is not considered more complex when it uses shorthand that the language provides for collapsing multiple statements into one
- Code is considered more complex for each "break in the linear flow of the code"
- Code is considered more complex when "flow breaking structures are nested"
Further reading
Line too long (85 > 79 characters) Open
Open
__name__, static_url_path="", static_folder="static", template_folder="templates"
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (86 > 79 characters) Open
Open
abs_filename = os.path.join(app.static_folder, values["filename"])
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (81 > 79 characters) Open
Open
app.blueprints[bp_name].static_folder, values["filename"]
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (85 > 79 characters) Open
Open
and publish data received from Wifi-equipped microcontrollers for a school contest"""
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (87 > 79 characters) Open
Open
logging.getLogger("apscheduler.executors.default").setLevel(LOGGING_LEVEL + 10)
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.