Use of assert detected. The enclosed code will be removed when compiling to optimised byte code. Open
assert not (
number_of_partitions > _MAX_SEGMENT_PARTITIONS
), f"Attempt to process {number_of_partitions} partitions is larger than the max of {_MAX_SEGMENT_PARTITIONS}, use a lower number of partitions"
- Exclude checks
Use of assert detected. The enclosed code will be removed when compiling to optimised byte code. Open
assert (
filter.filter_function or filter.query_string
), f"must define at least a filter function or query string when specifying a segment filter: {filter}"
- Exclude checks
Function _process_simple_partition
has a Cognitive Complexity of 19 (exceeds 5 allowed). Consider refactoring. Open
def _process_simple_partition(
partition_id: str,
schema: DatasetSchema,
segments: Dict[Segment, Any],
columns: List[str],
- Read upRead up
Cognitive Complexity
Cognitive Complexity is a measure of how difficult a unit of code is to intuitively understand. Unlike Cyclomatic Complexity, which determines how difficult your code will be to test, Cognitive Complexity tells you how difficult your code will be to read and comprehend.
A method's cognitive complexity is based on a few simple rules:
- Code is not considered more complex when it uses shorthand that the language provides for collapsing multiple statements into one
- Code is considered more complex for each "break in the linear flow of the code"
- Code is considered more complex when "flow breaking structures are nested"
Further reading
Function _filter_inputs
has a Cognitive Complexity of 9 (exceeds 5 allowed). Consider refactoring. Open
def _filter_inputs(
filter: SegmentFilter, pandas: Optional[pd.DataFrame] = None, row: Optional[Mapping[str, Any]] = None
) -> Tuple[Optional[pd.DataFrame], Optional[Dict[str, Any]]]:
assert (
filter.filter_function or filter.query_string
- Read upRead up
Cognitive Complexity
Cognitive Complexity is a measure of how difficult a unit of code is to intuitively understand. Unlike Cyclomatic Complexity, which determines how difficult your code will be to test, Cognitive Complexity tells you how difficult your code will be to read and comprehend.
A method's cognitive complexity is based on a few simple rules:
- Code is not considered more complex when it uses shorthand that the language provides for collapsing multiple statements into one
- Code is considered more complex for each "break in the linear flow of the code"
- Code is considered more complex when "flow breaking structures are nested"
Further reading
Avoid deeply nested control flow statements. Open
if _is_nan(val):
evaluations.append((pandas[col].isna()))
else:
evaluations.append((pandas[col] == val))
mask = reduce(lambda x, y: x & y, evaluations)
Function _log_segment
has a Cognitive Complexity of 7 (exceeds 5 allowed). Consider refactoring. Open
def _log_segment(
partition: SegmentationPartition,
schema: DatasetSchema,
obj: Any = None,
pandas: Optional[pd.DataFrame] = None,
- Read upRead up
Cognitive Complexity
Cognitive Complexity is a measure of how difficult a unit of code is to intuitively understand. Unlike Cyclomatic Complexity, which determines how difficult your code will be to test, Cognitive Complexity tells you how difficult your code will be to read and comprehend.
A method's cognitive complexity is based on a few simple rules:
- Code is not considered more complex when it uses shorthand that the language provides for collapsing multiple statements into one
- Code is considered more complex for each "break in the linear flow of the code"
- Code is considered more complex when "flow breaking structures are nested"
Further reading
TODO found Open
# TODO: consider if we need to combine with the column names
- Exclude checks
TODO found Open
# TODO segments filter
- Exclude checks
Line too long (80 > 79 characters) Open
from typing import Any, Dict, Iterable, Iterator, List, Mapping, Optional, Tuple
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (81 > 79 characters) Open
logger.debug(f"Done profiling for partition with name({partition_name})")
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (118 > 79 characters) Open
"Please use column segmentation, there are no columns defined and ColumnMapperFunction not yet supported."
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (90 > 79 characters) Open
_process_segment(pandas_segment, segment_key, segments, schema, segment_cache)
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (97 > 79 characters) Open
logger.info(f"The specified schema defines segments with {number_of_partitions} partitions.")
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (92 > 79 characters) Open
segment_key = Segment(tuple(str(row[element]) for element in columns), partition_id)
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (107 > 79 characters) Open
), f"must define at least a filter function or query string when specifying a segment filter: {filter}"
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (89 > 79 characters) Open
return SegmentedResultSet(segments=segmented_profiles, partitions=segment_partitions)
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (147 > 79 characters) Open
"SegmentFilter query string not supported when logging rows, either don't specify a filter or implement the filter.filter_function"
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (106 > 79 characters) Open
_process_simple_partition(partition.id, schema, segments, columns, pandas, row, segment_cache)
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (110 > 79 characters) Open
logger.debug(f"{partition_name}: is simple ({segment_partition.simple}), id ({segment_partition.id})")
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (84 > 79 characters) Open
from whylogs.core.segmentation_partition import SegmentationPartition, SegmentFilter
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (105 > 79 characters) Open
filter: SegmentFilter, pandas: Optional[pd.DataFrame] = None, row: Optional[Mapping[str, Any]] = None
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (90 > 79 characters) Open
logger.debug(f"{partition_name}: defines filter ({segment_partition.filter})")
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (148 > 79 characters) Open
), f"Attempt to process {number_of_partitions} partitions is larger than the max of {_MAX_SEGMENT_PARTITIONS}, use a lower number of partitions"
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.
Line too long (139 > 79 characters) Open
f"{partition_name}: defines mapper on colums ({segment_partition.mapper.col_names}) and id ({segment_partition.mapper.id})"
- Read upRead up
- Exclude checks
Limit all lines to a maximum of 79 characters.
There are still many devices around that are limited to 80 character
lines; plus, limiting windows to 80 characters makes it possible to
have several windows side-by-side. The default wrapping on such
devices looks ugly. Therefore, please limit all lines to a maximum
of 79 characters. For flowing long blocks of text (docstrings or
comments), limiting the length to 72 characters is recommended.
Reports error E501.