static/DSP-IS0005_0.1a/metadata/PDU_v1.xml
<?xml version="1.0" encoding="UTF-8"?>
<!---->
<!--################################################################################ -->
<!--# Redfish Schema: PDU v0.1.0-->
<!--# -->
<!--# For a detailed change log, see the README file contained in the DSP8010 bundle, -->
<!--# available at http://www.dmtf.org/standards/redfish -->
<!--# Copyright 2014-2017 Distributed Management Task Force, Inc. (DMTF). -->
<!--# For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright -->
<!--################################################################################ -->
<!---->
<edmx:Edmx xmlns:edmx="http://docs.oasis-open.org/odata/ns/edmx" Version="4.0">
<edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Core.V1.xml">
<edmx:Include Namespace="Org.OData.Core.V1" Alias="OData"/>
</edmx:Reference>
<edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Capabilities.V1.xml">
<edmx:Include Namespace="Org.OData.Capabilities.V1" Alias="Capabilities"/>
</edmx:Reference>
<edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Measures.V1.xml">
<edmx:Include Namespace="Org.OData.Measures.V1" Alias="Measures"/>
</edmx:Reference>
<edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/RedfishExtensions_v1.xml">
<edmx:Include Namespace="Validation.v1_0_0" Alias="Validation"/>
</edmx:Reference>
<edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Resource_v1.xml">
<edmx:Include Namespace="Resource.v1_0_0"/>
</edmx:Reference>
<edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/SensorCollection_v1.xml">
<edmx:Include Namespace="SensorCollection"/>
</edmx:Reference>
<edmx:DataServices>
<Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="PDU">
<EntityType Name="PDU" BaseType="Resource.v1_0_0.Resource" Abstract="true">
<Annotation Term="OData.Description" String="This is the schema definition for the PDU Metrics."/>
<Annotation Term="OData.LongDescription" String="This resource shall be used to represent a power metrics resource for a Redfish implementation."/>
<Annotation Term="Capabilities.InsertRestrictions">
<Record>
<PropertyValue Property="Insertable" Bool="false"/>
</Record>
</Annotation>
<Annotation Term="Capabilities.UpdateRestrictions">
<Record>
<PropertyValue Property="Updatable" Bool="true"/>
<Annotation Term="OData.Description" String="Power properties can be updated to change limits, exceptions and other writable properties."/>
</Record>
</Annotation>
<Annotation Term="Capabilities.DeleteRestrictions">
<Record>
<PropertyValue Property="Deletable" Bool="false"/>
</Record>
</Annotation>
</EntityType>
</Schema>
<Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="PDU.v0_1_0">
<EntityType Name="PDU" BaseType="PDU.PDU">
<Property Name="FirmwareRevision" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Firmware Revision of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Firmware Revision of PDU."/>
</Property>
<Property Name="HardwareRevision" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Hardware Revision of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Hardware Revision of PDU."/>
</Property>
<Property Name="DateOfManufacture" Type="Edm.DateTimeOffset">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The date of manufacture of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual date of manufacture of PDU."/>
</Property>
<Property Name="Manufacturer" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Manufacturer of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Manufacturer of PDU."/>
</Property>
<Property Name="Model" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Model Number of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Model Number of PDU."/>
</Property>
<Property Name="SerialNumber" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Serial Number of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Serial Number of PDU."/>
</Property>
<Property Name="PartNumber" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Part Number of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Part Number of PDU."/>
</Property>
<Property Name="AssetTag" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Asset Tag of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Asset Tag of PDU."/>
</Property>
<Property Name="PhysicalLocation" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Physical Location of PDU."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the actual Physical Location of PDU."/>
</Property>
<!-- System -->
<Property Name="InputSourceStatus" Type="Edm.Int64">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Input Source Status value of PDU."/>
<Annotation Term="OData.LongDescription" String="The value of this property shall represent the Input Source Availability Status value of PDU."/>
<Annotation Term="Validation.Minimum" Int="0"/>
</Property>
<Property Name="OutputSourceStatus" Type="Edm.Int64">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual Output Source Status value of PDU."/>
<Annotation Term="OData.LongDescription" String="The value of this property shall represent the Output Source Availability Status value of PDU."/>
<Annotation Term="Validation.Minimum" Int="0"/>
</Property>
<Property Name="AcInputSelectOverride" Type="Edm.String">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The actual AC Input Select Override of PDU."/>
<Annotation Term="OData.LongDescription" String="The value of this property shall represent the actual AC Input Select Override of PDU."/>
</Property>
<!-- AC Input -->
<NavigationProperty Name="AcInput" Type="Collection(PDU.v0_1_0.AcInput)">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
<Annotation Term="OData.Description" String="This is the definition for AC Input."/>
<Annotation Term="OData.LongDescription" String="These properties shall be the definition for AC Input for a Redfish implementation."/>
<Annotation Term="OData.AutoExpand"/>
</NavigationProperty>
<!-- AC Output -->
<NavigationProperty Name="AcOutput" Type="Collection(PDU.v0_1_0.AcOutput)">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/>
<Annotation Term="OData.Description" String="This is the definition for AC Output."/>
<Annotation Term="OData.LongDescription" String="These properties shall be the definition for AC Output for a Redfish implementation."/>
<Annotation Term="OData.AutoExpand"/>
</NavigationProperty>
<!-- Sensors -->
<NavigationProperty Name="Sensors" Type="SensorCollection.SensorCollection" Nullable="false">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="Contains the members of this sensor collection."/>
<Annotation Term="OData.AutoExpand"/>
</NavigationProperty>
<Property Name="Actions" Type="PDU.v0_1_0.Actions" Nullable="false">
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="The Actions property shall contain the available actions for this resource."/>
</Property>
</EntityType>
<!-- AC Input definition -->
<EntityType Name="AcInput" BaseType="Resource.v1_0_0.ReferenceableMember">
<Property Name="RealPower" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The Real Power for this AC Input."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the Real Power information of this AC Input."/>
<Annotation Term="Measures.Unit" String="kW"/>
</Property>
<Property Name="Energy" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The Energy for this AC Input."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the Energy information of this AC Input."/>
<Annotation Term="Measures.Unit" String="Hz"/>
</Property>
<Property Name="RmsUnderOverVoltage" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The RMS Under/Over Voltage for this AC Input."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the RMS Under/Over Voltage information of this AC Input."/>
<Annotation Term="Measures.Unit" String="V"/>
</Property>
<NavigationProperty Name="Sensors" Type="SensorCollection.SensorCollection" Nullable="false">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="Contains the members of this sensor collection."/>
<Annotation Term="OData.AutoExpand"/>
</NavigationProperty>
<Property Name="Actions" Type="PDU.v0_1_0.AcInputActions" Nullable="false">
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="The Actions property shall contain the available actions for this resource."/>
</Property>
</EntityType>
<!-- AC Output definition -->
<EntityType Name="AcOutput" BaseType="Resource.v1_0_0.ReferenceableMember">
<Property Name="RealPower" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The Real Power for this AC Output."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the Real Power information of this AC Output."/>
<Annotation Term="Measures.Unit" String="kW"/>
</Property>
<Property Name="Energy" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The Energy for this AC Output."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the Energy information of this AC Output."/>
<Annotation Term="Measures.Unit" String="Hz"/>
</Property>
<Property Name="RmsUnderOverVoltage" Type="Edm.Decimal">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="The RMS Under/Over Voltage for this AC Output."/>
<Annotation Term="OData.LongDescription" String="This property shall indicate the RMS Under/Over Voltage information of this AC Output."/>
<Annotation Term="Measures.Unit" String="V"/>
</Property>
<NavigationProperty Name="Sensors" Type="SensorCollection.SensorCollection" Nullable="false">
<Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/>
<Annotation Term="OData.Description" String="Contains the members of this sensor collection."/>
<Annotation Term="OData.AutoExpand"/>
</NavigationProperty>
<Property Name="Actions" Type="PDU.v0_1_0.AcOutputActions" Nullable="false">
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="The Actions property shall contain the available actions for this resource."/>
</Property>
</EntityType>
<ComplexType Name="Actions">
<Annotation Term="OData.AdditionalProperties" Bool="false"/>
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/>
<Property Name="Oem" Type="PDU.v0_1_0.OemActions" Nullable="false"/>
</ComplexType>
<ComplexType Name="OemActions">
<Annotation Term="OData.AdditionalProperties" Bool="true"/>
<Annotation Term="OData.Description" String="The available OEM specific actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain any additional OEM actions for this resource."/>
</ComplexType>
<ComplexType Name="AcInputActions">
<Annotation Term="OData.AdditionalProperties" Bool="false"/>
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/>
<Property Name="Oem" Type="PDU.v0_1_0.AcInputOemActions" Nullable="false"/>
</ComplexType>
<ComplexType Name="AcInputOemActions">
<Annotation Term="OData.AdditionalProperties" Bool="true"/>
<Annotation Term="OData.Description" String="The available OEM specific actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain any additional OEM actions for this resource."/>
</ComplexType>
<ComplexType Name="AcOutputActions">
<Annotation Term="OData.AdditionalProperties" Bool="false"/>
<Annotation Term="OData.Description" String="The available actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/>
<Property Name="Oem" Type="PDU.v0_1_0.AcOutputOemActions" Nullable="false"/>
</ComplexType>
<ComplexType Name="AcOutputOemActions">
<Annotation Term="OData.AdditionalProperties" Bool="true"/>
<Annotation Term="OData.Description" String="The available OEM specific actions for this resource."/>
<Annotation Term="OData.LongDescription" String="This type shall contain any additional OEM actions for this resource."/>
</ComplexType>
</Schema>
</edmx:DataServices>
</edmx:Edmx>